10 kHz microsecond pulsed X-ray generator utilising a hot-cathode triode with variable durations for biomedical radiography.

A 10 kHz pulsed X-ray generator utilising a hot-cathode triode in conjunction with a new type of grid control device for controlling X-ray duration is described. The energy-storage condenser was charged up to 70 kV by a power supply, and the electric charges in the condenser were discharged to the X-ray tube repetitively by the grid control device. The maximum values of the grid voltage (negative value), the tube voltage, and the tube current were -1.5 kV, 70 kV, and 0.4 A, respectively. The duration of the flash X-ray pulse was primarily determined by the time constant of the grid control device and the cut-off voltage of thermoelectrons. The X-ray duration was controlled within a region of less than 1 ms; the X-ray intensity with a pulse width of 0.27 ms, a charged voltage of 70 kV, and a peak tube current of 0.4 A was 0.92 microC kg-1 at 0.5 m per pulse. The maximum repetition rate was about 10 kHz, and the size of the focal spot was about 3.5 x 3.5 mm.

Animals↗

Disk-cathode flash X-ray tube driven by a repetitive two-stage Marx pulser.

Fundamental studies of a repetitive flash X-ray generator using a disk-cathode radiation tube are described. The high-voltage pulser employed a modified two-stage surge-Marx circuit. The two condensers in the pulser were charged from 40 to 60 kV, and the electric charges were discharged to the X-ray tube repetitively to generate flash X-rays. The total capacity during the main discharge was 425 pF, and the maximum output voltage from the pulser was about 1.9 times the charged voltage. The flash X-ray tube was of the demountable-diode type and was composed of a rod-shaped anode tip made of tungsten, a disk cathode made of graphite and a tube body made of polymethylmethacrylate. The peak tube voltage was primarily determined by the anode-cathode (A-C) space, and the peak tube current was less than 0.5 kA. Thus the maximum photon energy could be easily controlled by varying the A-C space, and the tube current roughly increased according to increases in the charged voltage. The pulse width ranged from 40 to 100 ns, and the X-ray intensity was less than 1.1 microC kg-1 at 0.5 m per pulse. The repetition rate was less than 50 Hz, and the effective focal spot size was equivalent to the anode diameter.

X-Ray Therapy↗