PubMed Health⌕ Search

Biomedical subjects

A Shiu

Publications and source records attributed to A Shiu.

At least 19 recordsLinked to original sources

An integrated treatment delivery system for CSRS and CSRT and clinical applications.

An integrated treatment delivery system for conformal stereotactic radiosurgery (CSRS) and radiotherapy (CSRT) has been developed through a collaboration involving Siemens Medical Systems, Inc., Tyco/Radionics, Inc., and The University of Texas M. D. Anderson Cancer Center. The system consists of a 6-MV linear accelerator (LINAC) equipped with a Tyco/Radionics miniature multileaf collimator (mMLC). For the conventional SRS treatment, the circular collimator housing can be attached to the opening window of the mMLC. The treatment delivery system is integrated with a radiotherapy treatment planning system and a record-and-verify system. The purpose of this study is to report the characteristics, performance, benefits, and the clinical applications of this delivery system. The technical specifications of the LINAC and mMLC were tested, and all the specifications were met. The 80% to 20% penumbral width for each mMLC leaf is approximately 3 mm and is nearly independent of the off-axis positions of a leaf. The maximum interleaf leakage is 1.4% (1.1% on average) and the maximum intra-leaf leakage is 1.0% (0.9% on average). The leaf position precision is better than 0.5 mm for all the leaves. The integration of the SRS/SRT treatment planning system, mMLC, and LINAC has been evaluated successfully for transferring the patient treatment data file through radiotherapy treatment planning system to the patient information and treatment record-and-verify server and the mMLC controller. Subsequently, the auto-sequential treatment delivery for SRS, CSRS/CSRT, and the step-and-shoot intensity-modulated radiotherapy has also been tested successfully. The accuracy of dose delivery was evaluated for a 2-cm spherical target in a Radiological Physics Center SRS head phantom with GAFChromic films and TLD. Five non-coplanar arcs, using a 2-cm diameter circular collimator, were used for this simulation treatment. The accuracy to aim the center of the spherical target was within 0.5 mm and the deviation of dose delivery to the isocenter of the target was within 2% of the calculated dose. For the irregularly shaped tumor, a tissue-equivalent head phantom was used to evaluate the accuracy of dose delivery for using either geometric conformal treatment or IMRT. The accuracy of dose delivery to the isocenter was within 2% and 3% of the calculated dose, respectively. From October 26, 1999 to September 30, 2002, we treated over 400 SRS patients and 70 SRT patients. Four representative cases are presented to illustrate the capabilities of this dedicated unit in performing conventional SRS, CSRS, and CSRT. For all the cases, the geometric conformal-plan dose distributions showed a high degree of conformity to the target shape. The degree of conformity can be evaluated using the target-volume-ratio (TVR). Our preferred TVR values for highly conformed dose distributions range from 1.6 to 2.0. The patient setup reproducibility for the Gill-Thomas-Cosman (GTC) noninvasive head frame ranges from 0.5 to 1 mm, and the head and neck noninvasive frame is within 2 mm. The integrated treatment delivery system offers excellent conformation for complicated planning target volumes with the stereotactic setup approach, ensuring that dose delivery can be achieved within the specified accuracy. In addition, the treatment time is comparable with that of single isocenter multiple-arc treatments.

Brain Neoplasms↗

Evaluating psychosocial nursing interventions for cardiac clients and their caregivers: a case study of the community rehabilitation network in Hong Kong.

AIM OF THE STUDY: The purpose of this exploratory study was to describe the type and nature of psychosocial nursing interventions provided for cardiac clients in Hong Kong's Community Rehabilitation Centres (CRNs). DESIGN/METHODS: Using a two-phase case study design data were collected from nurses, cardiac clients and their caregivers. The initial phase focused on identifying the types of psychosocial interventions provided. These data were obtained by observing nursing activities and the keeping of daily journals by the nurses. The second phase acquired data from structured telephone interviews, that reviewed clients' perceptions of the psychosocial interventions provided by the nurses and face-to-face interviews with clients and their caregivers. FINDINGS: These findings revealed that the nurses' interpersonal skills of information giving, social support and counselling were highly valued by cardiac clients and their caregivers. Both clients and caregivers outlined a concern about the lack of individual care and this was reflected in the focus of the CRN on group processes. CONCLUSION: Recommendations for psychosocial cardiac care are made for public health nurses and nurses working in community settings.

Aged↗

A pencil-beam photon dose algorithm for stereotactic radiosurgery using a miniature multileaf collimator.

A computer-controlled miniature multileaf collimator (MMLC) with 4 mm leaf width and a maximum field size of 6 cm X 6 cm has been designed as a tertiary beam-shaping device for linac-based stereotactic radiosurgery. The purpose of this study is to develop an accurate and efficient dose calculation model for use with the MMLC. A pencil-beam based algorithm using a sum of three Gaussian kernels was developed to model the off-axis ratio of MMLC fields. Because the kernel integration over a rectangular field can be solved in closed form, dose to any point from an arbitrary MMLC field can be calculated efficiently by summing dose contribution from a set of rectangular apertures and transmission blocks that model individual leaf openings or leaf transmissions. The model uses an effective rectangular field and equivalent square method for determination of depth dose and dose output. Results showed that the calculated percentage depth dose was within 1% and output factor was within 1.5% of measured data. The parameters of the pencil beam kernels were extracted by fitting measured off-axis profiles for a few field sizes at a few depths. The accuracy of the calculated off-axis ratio was tested by comparison with measured data for a number of MMLC fields. The algorithm was shown to be accurate to within 1.5% or 1 mm for off-axis ratios. The algorithm computes at a speed of 34,600 data points per second on a DEC Alpha server model 2000/433 (Digital Equipment Corp., Maynard, MA), which is about 15 times faster than a Clarkson-type summation method.

Algorithms↗

Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID).

A procedure has been developed using an electronic portal imaging device (EPID) to verify that the center of a patient's lesion is aligned with the center of a treatment cone prior to treatment in a linac-based stereotactic radiosurgery procedure. The coordinates of the lesion center are set on the Brown-Roberts-Wells phantom base using a target simulator. A 3 mm tungsten ball, mounted on the target simulator, is used as the reference point for the planned isocenter. The target simulator is then attached to an adapter mounted on the linac couch, and an EPID image of the simulated target is acquired. The center of the circular-shaped radiation field is calculated from the centroid of the segmented EPID image, and the center of the tungsten ball is identified by an automated computer search algorithm. A summation filter is used to find the position of the lowest radiation intensity coincident with the center of the ball. The alignment error is defined as the difference between the center of the radiation field and the center of the ball. The accuracy of this method was tested and found to be within 0.2 mm. The advantage of the EPID-based procedure is that it can give quantitative offset values quickly for immediate readjustment. We have found that the method is also a convenient tool for testing room laser alignment and the accuracy of the treatment cones.

Algorithms↗

An evaluation of the effectiveness of public health nursing: a case study of the maternal and child health centres in Hong Kong.

The aim of this study was to evaluate the effectiveness of public health nursing in Hong Kong using the maternal and child health centres as a case study. The case study design, employing both qualitative and quantitative methods of data collection, focused on clients' and nurses' perceptions of the effectiveness of care. The data analysis identified three important factors influencing the effectiveness of care: the need for a health needs data base, the organisation of care and service provision. From these findings the authors suggest that a health needs data base plays an essential role in measuring the effectiveness of care in public health nursing.

Attitude of Health Personnel↗

Surgery versus radiosurgery in the treatment of brain metastasis.

Surgery and radiosurgery are effective treatment modalities for brain metastasis. To compare the results of these treatment modalities, the authors followed 13 patients treated by radiosurgery and 62 patients treated by surgery who were retrospectively matched. Patients were matched according to the following criteria: histological characteristics of the primary tumor, extent of systemic disease, preoperative Karnofsky Performance Scale score, time to brain metastasis, number of brain metastases, and patient age and sex. For patients treated by radiosurgery, the median size of the treated lesion was 1.96 cm3 (range 0.41-8.25 cm3) and the median dose was 20 Gy (range 12-22 Gy). The median survival was 7.5 months for patients treated by radiosurgery and 16.4 months for those treated by surgery; this difference was found to be statistically significant using both univariate (p = 0.0018) and multivariate (p = 0.0009) analyses. The difference in survival was due to a higher rate of mortality from brain metastasis in the radiosurgery group than in the surgery group (p < 0.0001) and not due to a difference in the rate of death from systemic disease (p = 0.28). Log-rank analysis showed that the higher mortality rate found in the radiosurgery group was due to a greater progression rate of the radiosurgically treated lesions (p = 0.0001) and not due to the development of new brain metastasis (p = 0.75). On the basis of their data, the authors conclude that surgery is superior to radiosurgery in the treatment of brain metastasis. Patients who undergo surgical treatment survive longer and have a better local control. The data lead the authors to suggest that the indications for radiosurgery should be limited to surgically inaccessible metastatic tumors or patients in poor medical condition. Surgery should remain the treatment of choice whenever possible.

Adult↗

Soldering index for minimal coverage retainers.

The soldering index serves to record the precise alignment of the separate parts of a fixed partial prosthesis as positioned on the abutments. The use of an all-acrylic resin index is not as accurate as a plaster index. When impression plaster is used alone, it is difficult to place minimal coverage retainers such as inlays back into the index. This article describes a simple method that may overcome the difficulty without sacrificing the dimensional accuracy inherent in a plaster index.

Acrylic Resins↗

Colposcopically directed conization for frozen-section examination in the management of cervical intraepithelial neoplasia.

We found colposcopically directed conization for frozen-section (F/S) examination to be 100% accurate in ruling out the presence of invasive cervical carcinoma. Therefore, the definitive treatment for cervical intraepithelial neoplasia (CIN)--hysterectomy in women who do not want more children--could be performed while the patient was still under the anesthetic used during procurement of the conization specimen. This technique reduces the risk of using anesthesia a second time and also reduces the costs of CIN treatment. Colposcopically directed conization should be done by experienced colposcopists only.

Adult↗