PubMed Health⌕ Search

Biomedical subjects

A Sienkiewicz

Publications and source records attributed to A Sienkiewicz.

9 recordsLinked to original sources

Ultrawide band multifrequency high-field EMR technique: A methodology for increasing spectroscopic information.

We report methodology that combines an ultrawide band multifrequency microwave system with technology of high magnetic fields for solving challenging problems in electron magnetic resonance (EMR) spectroscopy. This strategy has been made possible due to a novel EMR facility operating in an exceptionally wide range of microwave frequencies of 24 GHz to 3 THz, at magnetic fields up to 17 T, and in the temperature range of 1.6 to 330 K. The basic configuration of the multifrequency system works in a transmission mode and employs oversized cylindrical waveguides for routing the microwave power. A wide-band, low-noise, liquid helium cooled (4.2 K) InSb bolometer is used for signal detection. This approach results in an extremely wide-band performance, thus making it possible to employ a variety of solid-state millimeter and submillimeter microwave sources in combination with a far infrared laser microwave source for performing multifrequency EMR experiments. A complexity of resonant structures and related technical problems such as microphonics at high magnetic fields is virtually eliminated. The system is simple, yet sensitive, and has been revealed to be extremely advantageous while solving such problems as observation of AFMR transitions in spin-ordered systems, g-factor resolution enhancement in complex organic radicals, and resonance signal detection in EMR-silent spin systems having integer spin and large zero field splitting. A technical description of the multifrequency high-field EMR facility is presented and results of its performance tests are given. The potential utility of using the multifrequency high-field methodology in EMR studies is illustrated with selected examples of its recent applications.

Electron Spin Resonance Spectroscopy↗

Dielectric resonator-based side-access probe for muscle fiber EPR study.

We present a novel dielectric resonator (DR)-based resonant structure that accommodates aqueous sample capillaries in orientations that are either parallel (i.e., side-access) or perpendicular to the direction of an external (Zeeman) magnetic field, B(0). The resonant structure consists of two commercially available X-band DRs that are separated by a Rexolite spacer and resonate in the fundamental TE(01delta) mode. The separator between the DRs is used to tune the resonator to the desired frequency and, by appropriately drilled sample holes, to provide access for longitudinal samples, notably capillaries containing oriented, spin-labeled muscle fibers. In contrast to the topologically similar cylindrical TE(011) cavity, the DR-based structure has distinct microwave properties that favor its use for parallel orientation of lossy aqueous samples. For perpendicular orientation of a dilute (6.25 microM) aqueous solution of IASL spin label, the S/N ratio was at least one order of magnitude better for the side-access DR-based structure than for a standard TE(102) cavity. EPR spectra acquired for maleimide spin-labeled myosin filaments also revealed ca. 10 times better S/N ratio than those obtained with a standard TE(102) cavity. For the side-access DR with sample capillaries oriented either parallel or perpendicular to the external magnetic field, the Q- and filling factors are in good agreement with the theoretical estimates derived from the distribution of magnetic (H(1)) and electric (E(1)) components.

Animals↗

Dielectric resonator-based flow and stopped-flow EPR with rapid field scanning: A methodology for increasing kinetic information.

We report methodology which combines recently developed dielectric resonator-based, rapid-mix, stopped-flow EPR (appropriate for small, aqueous, lossy samples) with rapid scanning of the external (Zeeman) magnetic field where the scanning is preprogrammed to occur at selected times after the start of flow. This methodology gave spectroscopic information complementary to that obtained by stopped-flow EPR at single fields, and with low reactant usage, it yielded more graphic insight into the time evolution of radical and spin-labeled species. We first used the ascorbyl radical as a test system where rapid scans triggered after flow was stopped provided "snapshots" of simultaneously evolving and interacting radical species. We monitored ascorbyl radical populations either as brought on by biologically damaging peroxynitrite oxidant or as chemically and kinetically interacting with a spectroscopically overlapping nitroxide radical. In a different biophysical application, where a spin-label lineshape reflected rapidly changing molecular dynamics of folding spin-labeled protein, rapid scan spectra were taken during flow with different flow rates and correspondingly different times after the mixing-induced inception of protein folding. This flow/rapid scan method is a means for monitoring early immobilization of the spin probe in the course of the folding process.

Antioxidants↗

Electronic structural information from Q-band ENDOR on the type 1 and type 2 copper liganding environment in wild-type and mutant forms of copper-containing nitrite reductase.

Q-band ENDOR elucidated proton and nitrogen hyperfine features to provide spin density information at ligands of blue-green Type 1 and catalytic Type 2 copper centers in nitrite reductase. The blue-green Type 1 center of nitrite reductase has a redox, electron-transfer role, and compared to the blue center of plastocyanin, it has the following structural differences: a shortened Cu-Smet bond length, a longer Cu-Scys bond length, and altered ligand-copper-ligand bond angles (Adman, E. T., Godden, J. W., and Turley, S. (1995) J. Biol. Chem. 270, 27458-27474). The hyperfine couplings of the two Type 1 histidine (N delta) ligands showed a larger percentage difference from each other in electron spin density than previously reported for other blue Type 1 proteins, while the cysteine beta-proton hyperfine couplings, a measure of unpaired p pi spin density on the liganding cysteine sulfur, showed a smaller electron spin density. A mutation of the Type 1 center, M182T, having the copper-liganding Met182 transformed to Thr182, caused the center to revert to an optically "blue" center, raised its redox potential by approximately 100 mV, and led to the loss of activity (prior paper). Surprisingly, in M182T there was no change from native Type 1 copper either in the histidine or cysteine hyperfine couplings or in g values and Cu nuclear hyperfine couplings. The conclusion is that the optical and redox alterations due to changed Type 1 methionine ligation need not be concurrent with electron spin delocalization changes in the HOMO as reported from its essential cysteine and histidines. A detailed picture of the nitrogen couplings from the three histidine (N epsilon) ligands of the Type 2 center indicated a substantial ( approximately 200%) electronic hyperfine inequivalence of one of the histidine nitrogens from the other two within the Type 2 HOMO and thus provided evidence for electronic distortion of the Type 2 site. In the presence of the nitrite substrate, hyperfine couplings of all histidines diminished. We suggest that this nitrite-induced decreased covalency would correlate with an increased Type 2 redox potential to assist electron transfer to the Type 2 center. Dipole-coupled, angle-selected exchangeable proton features, observed over a range of g values, predicted a ligand-water proton distance of 2.80 A from copper, and these water protons were eliminated by nitrite. His287 is not a Type 2 ligand but is positioned to perturb an axial water or a nitrite of Type 2 copper. In the presence of nitrite the mutant H287E showed no evidence for the loss of water protons and no diminished ligand histidine covalency. H287E has vastly diminished activity (prior paper), and the ENDOR information is that NO2- does not bind to Type 2 copper of H287E. In summary, the electronic information from this study of native and suitably chosen mutants provided a test of the highest occupied molecular orbital (HOMO) wave function at Type 1 and Type 2 coppers and an intimate electronic insight into functional enzymatic properties.

Copper↗

Kinetics and motional dynamics of spin-labeled yeast iso-1-cytochrome c: 1. Stopped-flow electron paramagnetic resonance as a probe for protein folding/unfolding of the C-terminal helix spin-labeled at cysteine 102.

The kinetics of chemically induced folding and unfolding processes in spin-labeled yeast iso-1-cytochrome c were measured by stopped-flow electron paramagnetic resonance (EPR). Stopped-flow EPR, based on a new dielectric resonator structure [Sienkiewicz, A., Qu, K., & Scholes, C. P. (1994) Rev. Sci. Instrum. 65, 68-74], gives a new temporal component to probing nanosecond molecular tumbling motions that are modulated by macromolecular processes requiring time resolution of milliseconds to seconds. The stopped-flow EPR technique presented in this work is a kinetic technique that has not been previously used with such a time resolution on spin-labeled systems, and it has the potential for application to numerous spin-labeled sites in this and other proteins. The cysteine-specific spin-label, methanethiosulfonate spin-label (MTSSL), was attached to yeast iso-1-cytochrome c at the single naturally occurring cysteine102, and the emphasis for this work was on this disulfide-attached spin-labeled prototype. This probe has the advantage of reflecting the protein tertiary fold, as shown by recent, systematic site-directed spin labeling of T4 lysozyme [Mchaourab, H. S. Lietzow, M. A., Hideg, K., & Hubbell, W. L. (1996) Biochemistry 35, 7692-7704], and protein backbone dynamics, as also shown by model peptide studies [Todd, A. P., & Millhauser, G. L. (1991) Biochemistry 30, 5515-5523]. The C-terminal cytochrome c helix where the label is attached is thought to be critical in the initial steps of protein folding and unfolding. Stopped-flow EPR resolved the monoexponential, guanidinium-induced unfolding process at pH 6.5 with an approximately 20 ms time constant; this experiment required less than 150 microL of 80 microM spin-labeled protein. We observed an approximately 50-fold decrease of this unfolding time from the 1 s range to the 20 ms time range as the guanidinium denaturant concentration was increased from 0.6 to 2.0 M. The more complex refolding kinetics of our labeled cytochrome were studied by stopped-flow EPR at pH 5.0 and 6.5. The spin probe showed a fast kinetic process compatible with the time range over which hydrogen/deuterium amide protection indicates helix formation; this process was monoexponential at pH 5.0. At pH 6.5, there was evidence of an additional slower kinetic phase resolved by stopped-flow EPR and by heme-ligation-sensitive UV-Vis that indicated a slower folding where heme misligation may be involved. Since the disulfide-attached probe has reported folding and backbone dynamics in other systems, the implication is that our kinetic experiments were directly sensing events of the C-terminal helix formation and possibly the N- and C-terminal helical interaction. The cysteine-labeled protein was also studied under equilibrium conditions to characterize probe mobility and the effect of the probe on protein thermodynamics. The difference in spin probe mobility between folded and denatured protein was marked, and in the folded protein, the motion of the probe was anisotropically restricted. The motion of the attached nitroxide in the folded protein appears to be restricted about the carbon and sulfur bonds which tether it to the cysteine. The original point of cysteine sulfur attachment is approximately 11 A from the heme iron within the C-terminal helix near its interface with the N-terminal helix, but the low-temperature EPR spin probe line width showed that the probe lies more distant (> 15 A) from the heme iron. By all physical evidence, the protein labeled at cysteine102 folded, but the spin probe in this prototype system perturbed packing which lowered the thermal melting temperature, the free energy of folding, the guanidinium concentration at the midpoint of the unfolding transition, the m parameter of the denaturant, and the helical CD signature. This study prepares the way for study of protein folding/unfolding kinetics using EPR spectroscopy of spin-labels placed at specific cysteine-mutated sites within

Circular Dichroism↗

Double-stacked dielectric resonator for sensitive EPR measurements.

A new approximate method for predicting the resonant frequencies and for solving the field distribution problem of a cylindrical dielectric resonator (DR) is developed. The model proposed in this paper bridges the gap between rigorous and accurate finite-element or Green function-based numerical methods on the one hand and on the other hand, simple approximate solutions in which the field distribution can be described analytically, but the resulting frequency is accurate within a few percent only. In the method described here, the approximate solution for the microwave field distribution is modified by substituting different values of the radial separation constants inside and outside of the diskshaped DR. The model is generalized for the double-stacked DR structure and enables one to introduce corrections that take into account the presence of the shielding walls and of the cylindrical sample hole. Good agreement is found between experimental and calculated results for both the single and double-stacked structures that are designed around commercially available X-band DRs (9-10 GHz). For the resonant frequency of the lowest transverse-electric TEzero1 delta mode that is commonly used for EPR measurements, the accuracy of the method is better than 1%. Experimentally measured resonator filling factors are also in good agreement with those theoretically estimated. Both the theory and the experimental results suggest that the double-stacked DR structure with finite spacing between the ceramic cylinders is the most suitable for EPR measurements of long lossy samples.

Ceramics↗