PubMed Health⌕ Search

Biomedical subjects

A Sims

Publications and source records attributed to A Sims.

53 records · Page 3Linked to original sources

Folie à quatre.

A case of folie à quatre is described affecting a proband and his wife, sister and brother. The three family members retained their symtoms of paranoid schizophrenia. The wife was not mentally ill and her delusions disappeared in time (folie imposée). Coincidentally, there were several cases of Huntington's chorea amongst her relatives. Different categories of folie à deux are demonstrated in the various family members and relationships.

Adult↗

Anger of African American women in the south.

In this existential-phenomenological investigation middle-class African American women (n = 9) in the Southern United States were interviewed about their experience of anger in daily life. The purpose of the study was to examine what African American women's anger is about, what it means, and how it is experienced. Transcribed interviews were analyzed using a hermeneutic process. The thematic structure of African American women's anger comprises three main elements that stand out as figural: power, control, and respect. These figural elements can be understood only when seen against the ground of a racist Southern culture that produces pervasive mistrust. These findings are of importance to clinicians, who cannot deliver culturally competent interventions to African American female clients without a clear understanding of the complexity and meaning of their anger experience.

Adult↗

Evaluation of the effectiveness of following up laboratory reports of elevated blood leads in adults.

The usefulness of a statewide laboratory-based blood lead surveillance system to initiate workplace enforcement inspections was studied. In particular, the effectiveness of inspection of companies in which at least one worker had a blood lead level (BLL) 30-39 microg/dL but no greater than 39 microg/dL was considered. The surveillance system identified all individuals who had been tested for blood lead. Adults with BLLs > or =30 microg/dL were interviewed. Companies where lead exposures occurred were identified and enforcement inspections performed there. Companies were grouped into four categories: one or more employees with BLL > or =50 microg/dL; one or more employees with highest BLL of 40-49 microg/dL; one or more employees with highest BLL of 30-39 microg/dL; and companies that used lead but from which no blood lead reports were received. The number of citations and amounts of penalties, and BLLs before and after, were compared among the three blood lead groups and with a control group of no lead-using companies. A cost-benefit analysis was performed. Citations and penalties did not differ among the three blood lead groups but were markedly increased compared with the lead using but no blood lead group. Violations of specific lead standard components were similar among the three blood lead groups. Blood lead companies had increased citations and penalties as compared with nonusing lead control companies. No significant decrease in blood leads was seen postinspection. Total cost to identify lead-exposed workers at problem work sites was $125 ($53-$459) per lead-exposed worker. Followup of companies identified through the surveillance system was an effective method to target workplace inspections. It is recommended that routine inspection be instituted for all companies in which an employee is reported to have a blood lead of 30 microg/dL or greater.

Adult↗

Simultaneous liquid chromatographic determination of thiamine and riboflavin in selected foods.

A reliable, improved liquid chromatographic (LC) method has been developed for the measurement of thiamine and riboflavin in foods. The major improvement in the method is the chromatographic separation achieved. The method is also very reproducible and extremely sensitive. After autoclave extraction, samples are derivatized to form thiochrome (a highly fluorescent oxidation product of thiamine). Riboflavin is naturally fluorescent. Interferences are removed on a C18 cartridge and chromatographed by using a reversed-phase separation. The mobile phase used is 72% 0.005M NH4OAc (pH 5.0)-28% MeOH. Fluorescence detection using wavelength switching, 370-435 for thiamine and 370-520 for riboflavin, allows determination of each vitamin at its optimum wavelength for maximum sensitivity. Detection limits were 0.05 ng for both thiamine and riboflavin. The method can also be performed by using a fluorescence detector at a single wavelength, but with a sacrifice of sensitivity. Data comparisons between AOAC fluorometric and LC results were excellent for routine samples, as well as for American Association of Cereal Chemists (AACC) check samples. All LC results from AACC samples were within 2 standard deviations of the mean. Reproducibility was 1.9% for thiamine and 1.6% for riboflavin.

Chromatography, Liquid↗