The measurement of silicon in a lung phantom--a comparison of two nuclear reactions for in vivo activation analysis.

The amount of silica in the human lung may be estimated by measurement of silicon using in vivo neutron activation analysis. A pulsed, fast neutron beam, produced with a 2 MV Van de Graaff generator using the 2H + 2H reaction, was used to irradiate a Si-doped chest phantom in order to determine minimum detection limits (MDL). Two 'in-beam' nuclear reactions on Si were studied; prompt fast neutron inelastic scatter 28Si (n,n' gamma)28Si reaction was measured during the beam burst and the slow neutron prompt capture reaction was measured between the fast neutron bursts. Although the latter reaction appeared less favourable due to neutron cross section and measurement efficiency considerations, it yielded an MDL of 1.8 g compared with 2.3 g for the 28Si(n,n' gamma)28Si reaction. A comparison was made with a 252Cf neutron irradiation system where a Si MDL of 6.3 g was obtained using the slow neutron capture reaction. The Van de Graaff system permits 'exposed' Si lung burdens to be measured but not normal levels. Improved measurement sensitivity may be achieved by reduction of high counting-rate losses and high background radiation.

Humans↗

Determination of total body calcium by prompt gamma neutron activation analysis: absolute in vivo measurements.

Sequential TBCa measurements using the prompt gamma ray technique are firmly established and a number of patient groups are under investigation. A technique has been proposed for the absolute measurement of TBCa based upon the use of TBCl as an internal standard. Further work is needed to establish the validity of the method, but the initial results are encouraging.

Body Composition↗

Calibration and evaluation of a 252Cf-based neutron activation analysis instrument for the determination of nitrogen in vivo.

A novel clinical instrument for multi-element in vivo neutron activation analysis has been recently constructed in Swansea. The instrument is intended primarily for prompt gamma measurement of total and partial body calcium, total body nitrogen and partial body cadmium. For the measurement of nitrogen the subject is scanned both prone and supine across a vertical collimated neutron beam from a 4 GBq 252Cf source. Two shielded Nal(TI) detectors, each of volume 2760 cm3, are placed above the subject on the opposite side to that irradiated. The prompt gamma ray spectrum contains prominent peaks from hydrogen, nitrogen, chlorine and carbon. The optimisation, calibration and evaluation of the instrument for the measurement of nitrogen, by the reaction 14N(n, gamma)15N, is described. The calibration corrects the ratio of nitrogen-to-hydrogen counts measured from the subject for background gamma rays and the effects of body habitus. Body hydrogen is use as as internal standard. Repeated measurements of a homogeneous anthropomorphic phantom indicate that the ratio of nitrogen-to-hydrogen counts may be determined by a coefficient of variation of 1.6% for a neutron dose equivalent incident on the phantom of 0.45 mSv (QF = 10). The accuracy of the calibration was assessed by measuring three anthropomorphic phantoms (weight range: 41.4-110 kg) containing simulated skeletons and the major organs of the body. For these phantoms the mean discrepancy of the measured to the known nitrogen content was +4.9%. The simultaneous measurement of chlorine and carbon is discussed.

Activation Analysis↗

A clinical instrument for multi-element in vivo analysis by prompt, delayed and cyclic neutron activation using 252Cf.

The design and construction of a versatile clinical instrument for multi-element in vivo neutron activation analysis of major and minor body elements is described. A 200 micrograms (4 GBq) 252Cf neutron source is stored below ground level and pneumatically propelled to one of two irradiation ports. These deliver collimated beams of fast neutrons either to a localised volume such as the liver or kidney, or across the width of a patient for a head-to-toe scanning whole-body measurement. The source control system allows selection of either a continuous or cyclic mode of activation. The instrument is intended primarily for measurement, by the prompt-gamma technique, of total and partial body calcium, total body nitrogen and partial body cadmium. The potential of the instrument for determination of these three elements has been established. Phantom results suggest that total body calcium can be measured with a precision of +/- 2.6% (CV) for an average whole-body skin dose equivalent of 6.4 mSv; total body nitrogen with a precision of +/- 2.0% for an average whole-body skin dose equivalent of less than 0.4 mSv; and a detection limit (2 SD of the background) of 2.4 mg of cadmium in the kidney has been obtained for a radiation dose equivalent to the skin of 3 mSv (QF = 10). The suitability of this instrument for the measurement of other elements is also discussed.

Californium↗

A feasibility study for the in vivo measurement of beryllium by photonuclear activation.

Diagnosis of the beryllium-induced disease, berylliosis, is often difficult and always requires that the presence of the metal in tissue be demonstrated. The feasibility of developing an in vivo method of measurement, which exploits the uniquely low photonuclear reaction threshold of 1.67 MeV in beryllium, has been investigated. Suitable photon sources and detector systems were assessed, both experimentally by phantom studies and theoretically by use of a Monte-Carlo neutron transport code. It is concluded that by using a filtered source of 124Sb for bilateral irradiation of the chest, and an array of twenty BF3 counters, beryllium could be measured to an accuracy of 0.33 mg per lung, which corresponds to a 2 SD detection limit of 0.67 mg, for a skin dose of 50 mGy delivered within a period of 90s. Such a facility would be capable of contributing to the aetiology of the disease in a large proportion of cases, but the wider use of the method for screening exposed workers would require further improvements in detection efficiency.

Beryllium↗

An in-vivo study of renal cadmium and hypertension.

A comparative study of renal cadmium burdens in a group of thirty hypertensive patients undergoing treatment and in a group of thirty matched controls is reported, both groups being volunteers selected from a non-occupationally exposed population. The aim of this study was to investigate the possible involvement of cadmium in the aetiology of hypertension at the chronic low levels of environmental exposure. Renal cadmium levels were measured in vivo, using the technique of partial-body neutron activation analysis. The results showed that the mean renal cadmium level in the hypertensive group [3.3 mg (SD 2.3)], was not significantly different from that [4.4 mg (SD 2.7)], in the normotensive group. Whether the level in the hypertensives depends on the treatment is open to question and will be the subject of further investigation. In addition, the results confirm that kidney cadmium levels are elevated in smokers.

Cadmium↗

Measurements of total body calcium by prompt-gamma neutron activation analysis using a 252Cf source.

A clinical neutron activation instrument has been developed for in vivo elemental analysis. Utilizing the prompt-capture gamma ray technique, simultaneous total body (TB) measurements of primarily Ca, but also Cl, N, C, and H are routinely performed. This paper describes a technique for the measurement of TBCa (g) that relies on the use of TBCl as an internal standard. The method has been tested with four anthropomorphic phantoms covering a range of body habitus. The mean discrepancy between the measured and known Ca contents was 3.6%. The technique has been applied to two patient groups, and encouraging results were obtained.

Body Composition↗