Writing subwavelength-sized structures into aluminium films by thermo-chemical aperture-less near-field optical microscopy.

An optical near-field at the tip of an atomic force microscope probe is utilised to pattern aluminium thin films on glass substrates by photo-thermally induced corrosion in water. Aluminium forms a thin passivating oxide layer when immersed into neutral water at room temperature. Owing to the high energy density of the near-field, the metal below the probe tip can be heated to 100 degrees C due to absorption of the light, which then provokes breakdown of the passivation and metal corrosion. The localised near-field is generated by tip-induced enhancement of an evanescent field originating from a laser beam, that is totally internally reflected at the glass-aluminium-water interface. The process is governed by surface plasmons excited in the aluminium film by the evanescent waves and the field enhancement of the probe tip. Holes of 40 nm diameter and lines below 100 nm width have been written into a 20-nm-thick aluminium film. Applications of the scanning probe lithography process may include the one-step fabrication of point contacts or contact masks for near-field optical lithography and reactive ion etching.

Journal Article↗

Fast contact-mode atomic force microscopy on biological specimen by model-based control.

The dynamic behavior of the piezoelectric tube scanner limits the imaging rate in atomic force microscopy (AFM). In order to compensate for the lateral dynamics of the scanning piezo a model based open-loop controller is implemented into a commercial AFM system. Additionally, our new control strategy employing a model-based two-degrees-of-freedom controller improves the performance in the vertical direction, which is important for high-speed topographical imaging. The combination of both controllers in lateral and vertical direction compensates the three-dimensional dynamics of the AFM system and reduces artifacts that are induced by the systems dynamic behavior at high scan rates. We demonstrate this improvement by comparing the performance of the model-based controlled AFM to the uncompensated and standard PI-controlled system when imaging pUC 18 plasmid DNA in air as well as in a liquid environment.

DNA, Bacterial↗

Fabrication of near-field optical apertures in aluminium by a highly selective corrosion process in the evanescent field.

A simple, one-step process to fabricate high-quality apertures for scanning near-field optical microscope probes based on aluminium-coated silicon nitride cantilevers is presented. A thin evanescent optical field at a glass-water interface was used to heat the aluminium at the tip apex due to light absorption. The heat induced a breakdown of the passivating oxide layer and local corrosion of the metal, which selectively exposed the front-most part of the probe tip from the aluminium. Apertures with a protruding silicon nitride tip up to 72 nm in height were fabricated. The height of the protrusion was controlled by the extent of the evanescent field, whereas the diameter depended on the geometry of the probe substrate. The corrosion process proved to be self-terminating, yielding highly reproducible tip heights. Near-field optical resolution in a transmission mode of 85 nm was demonstrated.

Aluminum↗

Investigation of the morphology of the lacunocanalicular system of cortical bone using atomic force microscopy.

Mechanical loading has been implicated as a powerful driving mechanism for interstitial fluid flow through bone. However, little information is available with regard to the morphology of bone fluid spaces, e.g., the canalicular wall, which would be expected to dictate the type of flow regime developing in the lacunocanalicular system under mechanical loads. The purpose of this study was to examine the fine structure of the lacunocanalicular system in cortical bone using atomic force microscopy (AFM), resin casting methods, and selective etching of the specimen surface. A resin-cast replica of the canalicular wall was produced and surface morphology and dimensions were observed using AFM in tapping mode. Material contrast was obtained using surface potential measurements. A striped pattern perpendicular to the canaliculus long axis with a periodicity of 125 nm dominated the structure of the canalicular wall; it is likely that this was caused by the imprint of collagen fibrils arranged in parallel, lining the canaliculus wall. The largest dimension measured for canalicular diameter was on the order of 500 nm. The regular dips and ridges caused by the collagen that lines the wall are a source of roughness which may influence shear stresses imparted by the fluid on the cell surface as well as mixing of solutes within the lacunocanalicular system. In addition, the lacunocanalicular wall lining is likely to affect physicochemical interactions between the fluid and bone matrix. This has important implications for modeling and understanding the microfluid mechanics and rheology of the fluid-filled lacunocanalicular network.

Animals↗

True optical resolution beyond the Rayleigh limit achieved by standing wave illumination.

During the last decade, various efforts have been undertaken to enhance the resolution of optical microscopes, mostly because of their importance in biological sciences. Herein, we describe a method to increase the resolution of fluorescence microscopy by illuminating the specimen with a mesh-like interference pattern of a laser source and electronic postprocessing of the images. We achieve 100-nm optical resolution, an improvement by a factor of more than 2 compared with standard fluorescence microscopy and of 1.5 compared with confocal scanning.

Animals↗

A hybrid scanning force and light microscope for surface imaging and three-dimensional optical sectioning in differential interference contrast.

The design of a scanned-cantilever-type force microscope is presented which is fully integrated into an inverted high-resolution video-enhanced light microscope. This set-up allows us to acquire thin optical sections in differential interference contrast (DIC) or polarization while the force microscope is in place. Such a hybrid microscope provides a unique platform to study how cell surface properties determine, or are affected by, the three-dimensional dynamic organization inside the living cell. The hybrid microscope presented in this paper has proven reliable and versatile for biological applications. It is the only instrument that can image a specimen by force microscopy and high-power DIC without having either to translate the specimen or to remove the force microscope. Adaptation of the design features could greatly enhance the suitability of other force microscopes for biological work.

Animals↗

Biological structures imaged in a hybrid scanning transmission electron microscope and scanning tunneling microscope.

A hybrid scanning transmission electron microscope (STEM) and scanning tunneling microscope (STM) is described which allows simultaneous imaging of biological structures adsorbed to electron-transparent specimen supports in both modes of scanning microscopy, as demonstrated on uncoated phage T4 polyheads. We further discuss the reproducibility and validity of height data obtained from STM topographs of biomacromolecules and present raw data from topographs of freeze-dried, metal-coated nuclear envelopes from Xenopus laevis oocytes.

Animals↗

Imaging biological macromolecules by STM: quantitative interpretation of topographs.

Methods are discussed which permit the calibration of x-, y-, z-sensitivities, non-linearities and frequency responses of the scanning device of a scanning tunneling microscope (STM) either by interferometry or directly from STM topographs. A technique is presented to measure the frequency response of the complete STM feedback unit and to derive a maximum speed in z direction which allows one to estimate the maximum scanning speed still permitting one to track surface corrugations. The signal transfer characteristics of a STM are evaluated in a direct comparison with high resolution transmission electron microscopy on an identical specimen area. The various effects of contaminants between tip and specimen and the finite tip radius receive special attention.

Cell Wall↗

Scanning tunneling and transmission electron microscopy on identical areas of biological specimens.

A methodology for tip and specimen-support manufacturing is described which allows for scanning tunneling microscopy (STM) and transmission electron microscopy (TEM) on identical areas of biological specimens, at comparable resolution. Topographs and dI/ds-maps were used to investigate tip-specimen interaction on native air-dried phage T4 polyheads where individual capsomeres and structural alterations upon repetitive scans have been observed at a tunnel current of 0.5 pA.