PubMed Health⌕ Search

Biomedical subjects

A Stengel

Publications and source records attributed to A Stengel.

3 recordsLinked to original sources

Anti-ghrelin Spiegelmer NOX-B11 inhibits neurostimulatory and orexigenic effects of peripheral ghrelin in rats.

BACKGROUND AND AIMS: Ghrelin, the natural ligand of the growth hormone secretagogue receptor 1a, is the most powerful peripherally active orexigenic agent known. In rodents, ghrelin administration stimulates growth hormone release, food intake, and adiposity. Because of these effects, blocking of ghrelin has been widely discussed as a potential treatment for obesity. Spiegelmer NOX-B11 is a synthetic l-oligonucleotide, which was previously shown to bind ghrelin. We examined the effects of NOX-B11 on ghrelin induced neuronal activation and food intake in non-fasted rats. METHODS: Animals received various doses of NOX-B11, inactive control Spiegelmer, or vehicle intravenously. Ghrelin or vehicle was administered intraperitoneally 12 hours later and food intake was measured over four hours. Neuronal activation was assessed as c-Fos-like immunoreactivity in the arcuate nucleus. RESULTS: Treatment with NOX-B11 30 nmol suppressed ghrelin induced c-Fos-like immunoreactivity in the arcuate nucleus and blocked the ghrelin induced increase in food intake within the first half hour after ghrelin injection (mean 1.13 (SEM 0.59) g/kg body weight; 4.94 (0.63) g/kg body weight versus 0.58 (0.58) g/kg body weight; p<0.0001). Treatment with NOX-B11 1 nmol or control Spiegelmer had no effect whereas treatment with NOX-B11 10 nmol showed an intermediate effect on ghrelin induced food intake. CONCLUSIONS: Spiegelmer NOX-B11 suppresses ghrelin induced food intake and c-Fos induction in the arcuate nucleus in rats. The use of an anti-ghrelin Spiegelmer could be an innovative new approach to inhibit the biological action of circulating ghrelin. This may be of particular relevance to conditions associated with elevated plasma ghrelin, such as the Prader-Willi syndrome.

Animals↗

EDI helps PHOs meet information needs.

While the organizational structures of physician-hospital organizations (PHOs) may differ from region to region, financial management of all PHOs requires that comparable information about the type and volume of patient services provided under each contract must be available so that the profitability of different contracts can be analyzed. However, comparable information often is not readily available. Obtaining these data is a challenge facing all PHOs. One Midwest healthcare system has designed and implemented an inexpensive electronic network that connects most of the participants in its PHO. This network has enabled the PHO to obtain information about the care provided under its contracts, information that would not be available otherwise.

Computer Communication Networks↗

Diagnostic accuracy of ultrasound and computed tomography in the staging of Hodgkin's disease. Verification by laparotomy in 100 cases.

BACKGROUND: A staging laparotomy still is considered the gold standard to detect occult abdominal involvement in Hodgkin's disease. Computed tomography and ultrasound are routinely available for diagnostic imaging. To the authors' knowledge, the exact contribution of ultrasound for the staging of Hodgkin's disease has not been reported in a large series of patients before this study. METHODS: The diagnostic accuracy of abdominal ultrasound was compared with that of computed tomography and laparotomy in 100 patients with biopsy-proven Hodgkin's disease. Liver, spleen, paraaortic, and iliac lymph nodes were evaluated separately. RESULTS: Seventeen patients had a higher disease stage after surgery (17%). Considering only patients without known abdominal disease (supradiaphragmatic involvement), 14/79 (18%) had a positive staging laparotomy. Ultrasound had superior sensitivity for detecting splenic involvement with Hodgkin's disease (sensitivity, 63% compared with 37% for computed tomography). The specificity of both methods for detecting splenic disease was identical (99% vs. 96%). Inhomogeneities of structure or small nodular infiltrates were detected preferentially by ultrasound. Hepatic involvement also was visualized better by ultrasound than by computed tomography. Lymph nodes at the splenic hilus were recognized by both methods with identical sensitivity (64% vs. 62%). Paraaortic and iliac lymph nodes were recognized with greater sensitivity by computed tomography than by ultrasound (sensitivity, 93% and 100% vs. 77% and 67%, respectively). CONCLUSIONS: These results indicate that ultrasound and computed tomography each have their weaknesses and strengths and therefore should be combined, if possible. Ultrasound is the fastest and least invasive method and has particular accuracy for detecting splenic involvement, whereas computed tomography is more accurate in detecting involvement of paraaortic or iliac lymph node. If cost is important in the staging of Hodgkin's disease and if computed tomography is considered the standard, patients whose results are negative by computed tomography should be examined by ultrasound, focusing on splenic texture and size. Even in the era of combined modality treatment, surgical staging may be necessary to detect occult abdominal disease in a certain number of cases.

Abdominal Neoplasms↗