PubMed Health⌕ Search

Biomedical subjects

A Stensgaard

Publications and source records attributed to A Stensgaard.

11 recordsLinked to original sources

Modeling the distribution of Schistosoma mansoni and host snails in Uganda using satellite sensor data and Geographical Information Systems.

The potential value of MODIS satellite sensor data on Normalized Difference Vegetation Index (NDVI) and land surface temperatures (LST) for describing the distribution of the Schistosoma mansoni-"Biomphalaria pfeifferi"/Biomphalaria sudanica parasite-snail system in inland Uganda, were tested by developing annual and seasonal composite models, and iteratively analysing for their relationship with parasite and snail distribution. The dry season composite model predicted an endemic area that produced the best fit with the distribution of schools with > or =5% prevalence. NDVI values of 151-174, day temperatures of 26-36 degrees C, and night temperatures of 15-20 degrees C were used as criteria for the prediction model. Using the same approach with host snail data indicated that most of Uganda is suitable "B. pfeifferi"/B. sudanica habitat, except for possibly the north-eastern region of the country. The parasite, however, appears to be restricted in its distribution in both the north-eastern and the south-western regions of Uganda. The absence of disease in the south-west can not be attributed to the absence of snail hosts. Results suggest a combination of satellite sensor data on temperature and standard climate data on precipitation, as the best ecological determinants of the S. mansoni-"B. pfeifferi"/B. sudanica system. Satellite composite models and logistic regression analysis, suggest low night time temperature as one of the significant factors inhibiting S. mansoni transmission in the south-western highland areas of Uganda. The developed models are, however, unique, representing species-specific ecologic preferences of the S. mansoni-"B. Pfeifferi"/B. sudanica system in inland Uganda. Further validation studies are needed to test the value of the model in other countries in East Africa.

Animals↗

Knee extensor strength, activation, and size in very elderly people following strength training.

Muscle strength, activation, and size were studied in 11 very elderly subjects (8 women and 3 men; age range, 85-97 years) who completed 12 weeks of strength training of the knee extensor muscles. Training increased the maximum amount of weight that could be lifted once (134%; P < 0.05) and maximum voluntary isometric strength, measured as both force recorded at the ankle with the knee flexed 90 degrees (17%, ns) and as torque with the knee flexed 60 degrees (37%; P < 0.05). Anatomical lean quadriceps cross-sectional area (LCSA) measured at midthigh using magnetic resonance imaging increased from 27.5 +/- 9.6 cm2 to 30.2 +/- 10.0 cm2 (9.8%; P < 0. 05) after training. Both before and after training, isometric strength was closely related to LCSA, but training resulted in no significant change in muscle force per unit area of quadriceps muscle. Using the twitch interpolation technique, muscle activation during a maximal voluntary isometric contraction was shown to be incomplete in all subjects before training (ranging from 69% to 93%) and was not significantly increased after training. An increase in skeletal muscle mass may have important functional and metabolic benefits for very elderly people.

Aged↗

N-Acetylaspartate distribution in rat brain striatum during acute brain ischemia.

Brain N-acetylaspartate (NAA) can be quantified by in vivo proton magnetic resonance spectroscopy (1H-MRS) and is used in clinical settings as a marker of neuronal density. It is, however, uncertain whether the change in brain NAA content in acute stroke is reliably measured by 1H-MRS and how NAA is distributed within the ischemic area. Rats were exposed to middle cerebral artery occlusion. Preischemic values of [NAA] in striatum were 11 mmol/L by 1H-MRS and 8 mmol/kg by HPLC. The methods showed a comparable reduction during the 8 hours of ischemia. The interstitial level of [NAA] ([NAA]e) was determined by microdialysis using [3H]NAA to assess in vivo recovery. After induction of ischemia, [NAA]e increased linearly from 70 micromol/L to a peak level of 2 mmol/L after 2 to 3 hours before declining to 0.7 mmol/L at 7 hours. For comparison, [NAA]e was measured in striatum during global ischemia, revealing that [NAA]e increased linearly to 4 mmol/L after 3 hours and this level was maintained for the next 4 h. From the change in in vivo recovery of the interstitial space volume marker [14C]mannitol, the relative amount of NAA distributed in the interstitial space was calculated to be 0.2% of the total brain NAA during normal conditions and only 2 to 6% during ischemia. It was concluded that the majority of brain NAA is intracellularly located during ischemia despite large increases of interstitial [NAA]. Thus, MR quantification of NAA during acute ischemia reflects primarily changes in intracellular levels of NAA.

Acute Disease↗

A two-compartment phantom for VOI profile measurements in small-bore 31P MR spectroscopy.

A two-compartment gel phantom for VOI profile measurements in volume-selective 31P spectroscopy in small-bore units is presented. The phantom is cylindrical with two compartments divided by a very thin (30 microm) polyethene film. This thin film permits measurements with a minimum of susceptibility influences from the partition wall. The phantom was used for evaluation of the volume selection method ISIS (image-selected in vivo spectroscopy). The position of the phantom was fixed in the magnet during the measurements, while the volume of interest (VOI) was moved stepwise over the border. The signal from the two compartments was measured for each position and the data were evaluated following differentiation. We have found this phantom suitable for VOI profile measurements of ISIS in small-bore systems. The phantom forms a useful complement to recommended phantoms for small bore-spectroscopy.

Biophysical Phenomena↗

Visual activation in infants and young children studied by functional magnetic resonance imaging.

The purpose of this study was to determine whether visual stimulation in sleeping infants and young children can be examined by functional magnetic resonance imaging. We studied 17 children, aged 3 d to 48 mo, and three healthy adults. Visual stimulation was performed with 8-Hz flickering light through the sleeping childs' closed eyelids. Functional magnetic resonance imaging was performed with a gradient echoplanar sequence in a l.5-T magnetic resonance scanner. Six subjects were excluded because of movement artifacts; the youngest infant showed no response. In 10 children, we could demonstrate areas of signal decrease during visual stimulation in the occipital cortex (mean decrease 2.21%), contrary to the signal increase observed in the adult controls (mean increase 2.82%). This decrease may be due to a higher proportional increase in oxygen extraction compared with increase in cerebral blood flow during activation. The different response patterns in young children and adults can reflect developmental or behavioral differences. Localization of the activation seemed to be age-dependent. In the older children and the adults, it encompassed the whole length of the calcarine sulcus, whereas it was restricted to the anterior and medial part of the calcarine sulcus in the younger infants. This may reflect a different functional organization of the young child's visual cortex or the on-going retinal development.

Adult↗

Planar quadrature coil design using shielded-loop resonators.

The shielded-loop resonator is known to have a low capacitive sample loss due to a perfect balancing. In this paper, it is demonstrated that shielded-loop technology also can be used to improve design of planar quadrature coils. Both a dual-loop circuit and especially a dual-mode circuit may benefit from use of shielded-loop resonators. Observations in measurements agree with theory for both a dual-loop coil and a dual-mode coil. The coils were designed for use as transmit/receive coil for 1H imaging and spectroscopy at 4.7 T in rat brain.

Animals↗

Twelve-hour brain lithium concentration in lithium maintenance treatment of manic-depressive disorder: daily versus alternate-day dosing schedule.

The 12-h brain lithium concentration was measured by lithium-7 magnetic resonance spectroscopy in ten manic-depressive patients receiving daily or alternate-day lithium carbonate treatment. The median dose of lithium carbonate was 800 mg in the daily treatment group and 1200 mg in the alternate-day group. Median 12-h serum lithium concentration in the two groups was 0.86 mmol l-1 and 0.55 mmol l-1, respectively, while the corresponding concentration in brain was 0.67 mmol l-1 and 0.52 mmol l-1, respectively. The 12-h brain lithium concentration was independent of lithium dosing schedule (multiple linear regression), but correlated significantly with the 12-h serum lithium concentration (P = 0.003; B = 0.53, 95% c.l. 0.24-0.82; beta = 0.83). Thus at identical 12-h serum lithium concentrations the 12-h brain lithium concentration is similar with both treatment regimes. As the risk of manic-depressive relapse during alternate-day lithium treatment is in our experience 3-fold greater than with daily treatment (at similar mean 12-h serum lithium concentration), the findings suggest that the difference in the prophylactic efficacy of the two dosing schedules is unrelated to differences in the 12-h brain lithium concentration.

Adult↗

Quantitative 1D saturation profiles on chalk by NMR.

Quantitative one-dimensional saturation profiles showing the distribution of water and oil in chalk core samples are calculated from NMR measurements utilizing a 1D CSI spectroscopy pulse sequence. Saturation profiles may be acquired under conditions of fluid flow through the sample. Results reveal that strong saturation gradients exist in chalk core samples after core floods, due to capillary effects. The method is useful in analysis of corefloods, e.g., for determination of capillary pressure functions.

Calcium Carbonate↗

24-hour lithium concentration in human brain studied by Li-7 magnetic resonance spectroscopy.

Brain and serum lithium concentrations were measured every second hour during a 24-hr period following lithium intake, and again 48-hr later in two normal subjects in steady state lithium treatment receiving lithium carbonate (Priadel Synthelabo) once every evening. The brain-lithium concentration was measured by 7Li magnetic resonance spectroscopy (MRS). The brain lithium level was found to undulate in a peak-trough pattern that followed the serum lithium profile, although in an attenuated form. The brain/serum lithium concentration ratio varied considerably during the 48-hr period, ranging from 0.5 to 1.3, but the ratio was independent of the serum-lithium concentration. The median half-life for lithium was 28 hr in the brain, and 16 hr in serum. The brain lithium concentration in the morning was about 75% of the clinically relevant standard 12-hr serum lithium concentration. The finding that brain lithium undulates during the day means that MRS measurements of brain lithium can only be compared if carried out under standard conditions that include a fixed interval following lithium intake and an identical treatment regimen.

Adult↗

Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation.

A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms. The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation.

Brain↗

Accuracy and precision of MR velocity mapping in measurement of stenotic cross-sectional area, flow rate, and pressure gradient.

Reliability of magnetic resonance (MR) velocity mapping to assess severity of stenosis was assessed in vitro. Steady flow at different flow rates through five stenoses with a central orifice area ranging from 17 to 176 mm2 was measured with velocity mapping performed perpendicular to the stenotic jet. Besides determination of the stenotic cross-sectional area and flow rate, the pressure gradient was calculated with the modified Bernoulli equation and compared with manometer measurements. Cross-sectional areas were measured with an accuracy of > or = 76%, a precision of > or = 91%, and an error of < or = 19 mm2. Flow rates had an accuracy of > or = 72%, a precision of > or = 94%, and an error of < or = 1.4 L/min. The modification of the Bernoulli equation limited its reliability to stenoses with areas of 35-113 mm2. Pressure gradients were calculated with an accuracy of > or = 80%, a precision of > or = 88%, and an error of < or = 15 mm Hg. The method was applied in a single patient with aortic stenosis and gave estimates that agreed with those obtained by heart catheterization.

Aortic Valve↗