PubMed Health⌕ Search

Biomedical subjects

A Stortelder

Publications and source records attributed to A Stortelder.

2 recordsLinked to original sources

Liquid-core waveguide technology for coupling column liquid chromatography and Raman spectroscopy.

The on-line coupling of liquid chromatography (LC) and Raman spectroscopy (RS) via an entirely plastic liquid-core waveguide (LCW) was optimized in terms of excitation wavelength of the laser, especially in relation to the fluorescence background, and the length of the LCW. Excitation at 632.8 nm (He-Ne laser) was found to be a good compromise between a wavelength long enough to strongly reduce the fluorescence background and, on the other hand, short enough to avoid (re)-absorption of laser light and Raman signals by H2O in LCWs of considerable length. This conclusion is supported by a theoretical discussion on the optimization of LCW lengths as function of the excitation wavelength for H2O and 2H2O. When using the He-Ne laser the optimum length is approximately 50 cm for H2O; this corresponds to a detection cell volume of 19 microl for an LCW of 220 microm I.D., which is fully compatible with conventional-size LC. The influence of an organic modifier, usually necessary for reversed-phase LC, on the free spectral window was evaluated. The potential applicability of LC-LCW-RS was shown for a mixture of adenosine 5'-monophosphate (AMP), guanosine 5'-monophosphate (GMP) and uridine 5'-monophosphate (UMP), utilizing an aqueous eluent without the addition of a modifier. Improved detectability was achieved by using the stopped-flow mode and applying a large-volume-injection procedure (injection volume: 200 microl). Under these conditions, the limit of identification for AMP, GMP and UMP was in the 0.1-0.5-mg/ml range.

Adenosine Monophosphate↗

Secondary ion-molecule reactions in matrix-assisted laser desorption/ionization

Ion-molecule charge- and proton-transfer reactions in the desorption plume are considered for the case of matrix-assisted laser desorption/ionization (MALDI) with ultraviolet laser excitation, and it is proposed that they are major determinants of the observed mass spectrum. Specific MALDI phenomena which are discussed include the dominance of singly charged ions and analyte-matrix or analyte-analyte signal suppression. Should any be formed, highly charged products can be reduced by reaction with neutral matrix, yet singly charged ions cannot generally be neutralized in the same manner. Ion suppression effects can also be explained by similar reactions, which in some cases involve interconversion of dissimilar ion types. The plume is proposed often to be more under thermodynamic rather than kinetic control owing to these secondary reactions. UV/MALDI mass spectra should therefore be largely predictable, given sufficient thermodynamic information, and appropriate experimental conditions of sufficient analyte and plume density. Copyright 2000 John Wiley & Sons, Ltd.

Journal Article↗