PubMed HealthSearch

Biomedical subjects

A Swami

Publications and source records attributed to A Swami.

11 recordsLinked to original sources

Flow characteristics of long spinal needles.

A 120 mm, 27-gauge needle has recently been introduced for subarachnoid anaesthesia when using a single-space, combined spinal-extradural technique. The flow characteristics of this needle were compared with those of a 120 mm, 26-gauge needle using a pressure monitor infusion pump. Surprisingly, the resistance to fluid flow of the 26-gauge needle was twice that of the 27-gauge needle. The results of this experiment were confirmed by the findings of a clinical study undertaken in 100 obstetric patients who required regional anaesthesia. The time taken from dural puncture to appearance of cerebrospinal fluid at the hub of the needle was on average three times greater with the 26-gauge needle.

Adult

Posture and the spread of hyperbaric bupivacaine in parturients using the combined spinal epidural technique.

This study was undertaken to analyze the effect of posture on the spread of hyperbaric bupivacaine in pregnant women using a combined spinal extradural technique, and to assess the quality of analgesia provided by 10 mg bupivacaine when using this technique. Fifty parturients undergoing elective Caesarean section under regional anaesthesia were randomly allocated to receive 2.0 ml hyperbaric bupivacaine 0.5% in either the sitting or left lateral position. Spinal injection was performed with a 27 gauge, 120 mm long spinal needle using a single space combined spinal extradural technique. The onset time to analgesia at T4, and grade 3 motor block was on average 7.7 min and 6.9 min respectively in the lateral group, compared with 10.8 min (P < 0.05) and 9.4 min (P < 0.05) in the sitting group. Nine women in the sitting group and one woman (P < 0.05) in the lateral group required epidural supplementation. Hypotension occurred in 48% of the parturients in the lateral group and in 13% (P < 0.05) of the parturients in the sitting group. Nausea was noted in 61% of the parturients in the lateral group and in 22% (P < 0.05) of the parturients in the sitting group. There was no difference between the two groups in neonatal outcome. Overall, the position of the patient during induction of spinal anaesthesia does influence the rate of onset of analgesia and motor blockade. Injection of 10 mg hyperbaric bupivacaine in the sitting position would not provide adequate analgesia for Caesarean section when using a single space combined spinal extradural technique.

Adult

A comparison of the effects of captopril and flosequinan in patients with severe heart failure.

Angiotensin converting enzyme inhibitors have greatly improved the treatment of patients with chronic heart failure but they are not effective in all patients, and their use may be limited by side effects. There is, therefore, a need to investigate new drugs and to compare their efficacy with angiotensin converting enzyme inhibitors. Flosequinan is a new direct-acting vasodilator that has been shown to be effective in placebo-controlled studies. Patients with chronic heart failure in NYHA classes II or III who remained symptomatic despite at least 80 mg of frusemide daily were recruited from two centers. Following a single-blind placebo run-in period, the patients were randomized double blind to either the addition of captopril or flosequinan for 6 weeks. Following a further 2-week placebo washout period, they were then given the alternative treatment. Symptom-limited treadmill exercise times, scores of perceived exertion, and corridor walk tests were measured at two weekly intervals during the study. Twenty-five patients entered the study, 16 of whom completed without a change in diuretic dose. Five patients were withdrawn while taking captopril and two while taking flosequinan; two were withdrawn during the placebo washout period. For those patients who completed the study, flosequinan increased treadmill exercise tolerance from a mean (SEM) placebo time of 11.5 (1.0) minutes by 2.4 (0.6) (p = 0.0002) and captopril from 12.0 (0.8) minutes by 1.2 (0.6) minutes (p = 0.08). Comparison of the other measures of efficacy revealed no difference between the groups. In this short-term study flosequinan appeared to be equal in efficacy to captopril.

Aged

The pulmonary physician and critical care. 2. The injured lung: conventional and novel respiratory therapy.

Several alternatives to conventional ventilation in acute lung injury are now available and have been investigated to a varying degree. The assessment of all such techniques is limited by difficulties in designing proper comparative studies and by the time needed to recruit a large number of appropriate patients with acute lung injury. A common theme of lung volume maintenance combined with strategies designed to limit the extent of ventilator induced lung damage has emerged and should encourage reassessment of the conventional approach. The results of several large prospective comparative studies are eagerly awaited. Meanwhile we may reasonably suggest that improvements in respiratory support, together with advances in microbiological and pharmacological treatment, have the potential for improving the persistently disappointing survival rate in acute lung injury.

Acute Disease

The transmission of signals by auditory-nerve fiber discharge patterns.

Recent developments in the theory of point processes are used to analyze the accuracy by which signals are conveyed by the discharges of single auditory-nerve fibers. It is shown that the only spike trains which can convey a signal without distortion are those well-described by a Poisson process model. Theoretical predictions are made of the distortion present in the transmission of signals by auditory-nerve fiber discharge patterns. Absolute refractory effects are shown to result in more distortion than relative refractory ones. Procedures are developed to compensate for these distortions. The procedures designed to compensate for absolute refractory effects operate on the PST histogram. Computer simulations are used to confirm the theoretical predictions and to assess the accuracy of the compensation techniques.

Animals