PubMed Health⌕ Search

Biomedical subjects

A T Barker

Publications and source records attributed to A T Barker.

At least 37 records · Page 2Linked to original sources

Magnetic stimulation of the human brain and peripheral nervous system: an introduction and the results of an initial clinical evaluation.

This report describes a novel method of stimulating the motor cortex and deep peripheral nerves in humans. The technique, developed in the Department of Medical Physics of Sheffield University, uses a large pulse of magnetic field to induce currents within the body and is painless. The basic principles of magnetic stimulation are described, and the technique is compared with conventional electrical stimulation. Safety aspects are discussed with reference to established clinical electrical and magnetic procedures. The results of the first clinical study using magnetic stimulation are described and show clear central motor pathway slowing in multiple sclerosis patients.

Adult↗

Pulsed magnetic field therapy for tibial non-union. Interim results of a double-blind trial.

Patients with tibial fractures which had remained un-united for at least 52 weeks were randomly allocated to either active or dummy pulsed magnetic field stimulators and treated in full leg plasters for 24 weeks with a non-weightbearing conservative regimen, as is usual with such techniques. Fractures in 5 of the 9 patients with working machines united and fractures in 5 of the 7 patients with dummy machines also united. These early results of this double-blind trial are compatible with a difference in success rate at 24 weeks on active treatment of + 33% to -61% (95% confidence limits) compared with the success rate on the dummy stimulators. The high proportion of fractures uniting in the control group suggests that conservative management of non-union is effective and this may explain much of the success attributed to pulsed magnetic field therapy.

Adult↗

The effects of pulsed magnetic fields of the type used in the stimulation of bone fracture healing.

The main impression received by us whilst writing this review is the scarcity of technical data in the clinical studies and the total absence of controlled trials. The spatial patterns of the stimulus have not been measured, and no experiments have proved that there is an effect from the magnetic field itself. Control experiments using dummy stimulators must be done, since the orthopaedic management of the stimulated patients is different from conventional management and this may have significant and beneficial clinical effects. There is no clinical study at present which shows a direct therapeutic benefit due solely to the application of the magnetic field component of the overall treatment regime. The in vivo animal experiments suggest that there may be effects due to the magnetic fields used but results are very scarce compared with the accumulated data from direct current stimulation. In vitro studies are far removed from the clinical situation, but could nonetheless prove useful if the opportunity of controlling the stimulus can be taken. In the majority of experiments, approximately spatially uniform magnetic fields have been applied, but temporal changes in the magnetic field and both spatial and temporal variation in electric field lead to non-uniform stimulation. Little attempt has been made to assess or control the induced fields by defining the system geometry. Hence it is still unknown whether effects are due to the magnetic field, the induced extracellular electric field or to fields induced at cellular level by regions of different conductivity. In conclusion, we believe that, unlike steady current work, the pulsed magnetic field treatment of fractures has not been sufficiently well investigated and, although some of the animal experiments suggest significant effects, the benefit of using magnetic fields in the clinical management of non-union and delayed union has still to be proven. Double blind trials are essential and, if these do prove that there is a definite effect of the fields, the mechanisms must then be studied using a combination of theoretical, in vivo and in vitro techniques.

Animals↗

Human skin battery potentials and their possible role in wound healing.

Measurements of transcutaneous voltage have been made on seventeen normal volunteers. The results show the presence of 'skin battery' voltages comparable in size to those previously reported for amphibian and mammalian skin. No correlation was found between battery voltage and age or sex in the group studied, but consistent anatomical variations were observed. The possible role of these voltages in the natural wound healing process is discussed.

Adult↗

A study of the effects of glutaraldehyde and formaldehyde on the mechanical behaviour of bovine pericardium.

The inherent variability in the mechanical behavior of bovine pericardium causes difficulties in establishing the effects of treatment procedures used in the manufacture of bioprosthetic cardiac valves. A new experimental technique has been developed in which the specimen acts as its own control, obviating the need to perform large numbers of experiments to obtain statistically significant results. The procedure used is described in detail as is the equipment employed. The technique was used to assess the effect of glutaraldehyde and formaldehyde on the stress/strain response of bovine pericardium. The results show that the fixing process in glutaraldehyde is virtually complete within two hours and causes significant changes in the mechanical behaviour of the tissue. The tissue becomes progressively stiffer as the treatment period is extended, which is especially pronounced at low levels of stress. Formaldehyde storage subsequent to fixing in glutaraldehyde was found to have no effect on the stress/strain response of the bovine pericardium.

Aldehydes↗

The glabrous epidermis of cavies contains a powerful battery.

Voltages across various glabrous (and gland-free) regions of cavy skin range from 30 to 100 mV, inside positive; across hairy ones, 0 to 10 mV. (moreover, hairy areas also tend to maintain lower transcutaneous voltages in man.) When an incision is made through the glabrous epidermis of the cavy, a microampere flows through each millimeter of the cut's edge. These wound currents generate lateral, intraepidermal voltage gradients or fields of about 100-200 mV/mm near the cut; fields which decline with distance from the cut with a space constant of 0.3-0.4 mm. It is deduced from these data that the epidermis near a cut drives up to 300 microA/cm2 across itself; moreover, these currents and potentials can be grossly, rapidly, and (to some extent) reversibly reduced by amiloride. It is concluded that the hair and gland-free skin of cavies has a battery comparable in power and character to that of frogs; but it is suggested that this mammalian battery may primarily subserve epidermal wound healing rather than salt uptake.

Animals↗

The design of a clinical electromagnetic bone stimulator.

The design and construction of an air-cored electromagnetic bone stimulator is described. The magnetic field waveform chosen has been based on that used for in vitro studies and is the one most commonly found in clinical practice. Detailed information on the circuitry involved, the waveforms and field strengths produced and the design of coils is presented. This should enable the stimulator to be constructed either for clinical use or to generate fields for laboratory evaluation.

Bone and Bones↗

The mechanical properties of human dura mater and the effects of storage media.

Data are presented on the tensile strength and ultimate extensibility of human dura mater. Experiments were performed, prior to, and after, storage in glycerol. The results indicate that storage in glycerol has a small effect on the measured mechanical properties, but this was not statistically significant. In addition, storage in saline after glycerol preservation for up to thirty days was found to have no effect on the mechanical properties of dura mater, as long as the tissue had previously been sterilised and sterility was maintained. However, the considerable variability found in the mechanical properties of human dura prevented this being established beyond doubt. The implications of this variability for tissue selection is discussed.

Adult↗