PubMed Health⌕ Search

Biomedical subjects

A T Elliott

Publications and source records attributed to A T Elliott.

66 records · Page 4Linked to original sources

Mobile gamma cameras and 99mTc-labelled phosphates in acute myocardial infarction.

99mTc-labelled phosphates (PyP, IDP and MDP) were compared for their usefulness for the diagnosis of myocardial infarction. The results indicated the superiority of 99mTc-labelled imidodiphosphonate over the other 99mTc-labelled phosphates. At the same time, two mobile gamma cameras were compared with respect to their instrumental characteristics and clinical versalitity and their advantages and disadvantages are reported.

Diphosphates↗

Detection of a false left ventricular aneurysm by first-pass radionuclide ventriculography.

A false left ventricular aneurysm complicating an inferior myocardial infarction was successfully identified by computerized first-pass radionuclide ventriculography using a multicrystal gamma camera. The aneurysmal chamber exhibited paradoxical systolic expansion, a pattern of contraction confirmed by contrast cineangiography. Because of the propensity of false aneurysms to rupture, early noninvasive firm diagnosis is desirable and may be accomplished by first-pass radionuclide angiography.

Cineangiography↗

99mTc-imidodiphosphonate: a superior radio-pharmaceutical for in vivo positive myocardial infarct imaging. I: Experimental data.

99mTc-Imidodiphosphonate (99mTc-IDP) was investigated as an agent for nuclear medicine imaging of acute myocardial infarctions. For this purpose a suitable animal model was found. After coronary artery ligation reproducible myocardial infarcts were obtained with 80% of surviving animals. Scans of the myocardial infarcts were recorded with a high resolution gamma camera and good quality images were obtained. 99mTc-IDP ratios for normal and infarcted tissue were calculated and compared with similar data available from other 99mTc-labelled phosphates. With an infarct/normal ratio of 21:1, 99mTc-IDP is so far the best radiopharmaceutical for nuclear medicine imaging of necrosed heart muscle. Images of the myocardial infarcts have been recorded as early as 6 hours after infarction.

Animals↗

99mTc-imidodiphosphonate: a superior radio-pharmaceutical for in vivo positive myocardial infarct imaging. II: Clinical data.

99mTc-Imidodiphosphonate was investigated as a new myocardial infarct imaging agent. In the acute phase, 50 patients admitted to the coronary care unit were serially scanned over a period of 7 days. A mobile gamma camera linked on line to a remote data processor was used. Because of higher uptake in infarcted myocardium and faster blood clearance, superior images than those recorded with 99mTc-pyrophosphate were obtained. Its ease of preparation, low cost, and favourable dosimetry (because of its label with conventional 99mTc) transforms this agent into the present radiopharmaceutical of choice for acute infarct imaging in particular if sizing and follow-up is intended versus time and type of treatment. In this series, no false positive cases were seen. The sensitivity of the method in the detection of full thickness myocardial infarction was 95%. It dropped to 70% in the detection of subendocardial infarction. However, some of these apparent false negative cases may reflect severe ischaemia without infarction. It is postulated that this discrimination may not always be realistic.

Diphosphonates↗

High-quality, high-throughput, early whole-body bone scanning.

99mTc-IDP allows for high-quality, high-throughput and early whole-body bone scanning. Whole-body bone scans obtained at 30 min after intravenous administration of the tracer were compared with the standard and delayed 180 min p.i images. A subtraction technique allowed for the anlysis of the 30 min scans and it was found that in both types of investigation the same clinical information was present. This procedure will therefore increase considerably the throughput of whole-body bone scans in a busy department of nuclear medicine. It is however inadequate for detailed analysis of the skeleton (evaluation of benign bone disease).

Adult↗

Comparison of repeatability of the multifocal electroretinogram and Humphrey perimeter.

Functional mapping of the retina by multifocal electroretinographic recordings is now possible. We compared the normal range, repeatability and response topography of this new technique with conventional static Humphrey perimetry to assess its suitability in clinical practice. The multifocal technique was performed on 60 age-matched controls. Measures of repeatability and reproducibility were obtained. Results were then compared with those obtained from a customized perimetry test. In both tests the coefficients of repeatability were found to decrease with eccentricity. The inherent measurement variation between techniques was comparable. Overall system variation indicates that the technique could be a useful tool at the clinical level.

Computer Graphics↗

The effect of filter bandwidth on the multifocal electroretinogram.

The effect of filter bandwith on the multifocal electroretinogram was assessed by means of theoretical calculation, electronic simulation and real multifocal electroretinogram recordings. Waveform distortion by high-pass filtering on simulated square waves, normal electroretinogram waveforms and negative electroretinogram waveforms was demonstrated. The theory of the effect of differentiation on electroretinogram waveform shape by electronic filtering indicates that little effect would be observed by changing the input filter cut-off for normal electroretinographic waveform shapes. However, negative electroretinogram waveforms are differentiated when the high-pass filter setting is increased. The differentiation effect artificially recreates a positive component that could be mistaken as a b-wave component. To eliminate this effect when recording multifocal electroretinograms, a high-pass filter setting of less than 1 Hz should be used to preserve the true electroretinographic waveform shape.

Computer Simulation↗

Recanalization of arteries by laser radiation.

Following the success of balloon angioplasty as a non-operative technique for the recanalization of stenosed arteries, particularly those of the heart itself, work is being carried out to determine whether it would be possible to use laser radiation for this purpose. Both Nd:YAG and argon radiation have been shown to be capable of destroying atheromatous plaque, the major problem in vivo being perforation of the artery wall. The technique shows promise but much experimental work remains to be done.

Animals↗