PubMed HealthSearch

Biomedical subjects

A Tappe

Publications and source records attributed to A Tappe.

At least 19 recordsLinked to original sources

Change of Na+ pump current reversal potential in sheep cardiac Purkinje cells with varying free energy of ATP hydrolysis.

1. The Na(+)-K+ pump current, Ip, of cardioballs from isolated sheep cardiac Purkinje cells was measured at 30-34 degrees C by means of whole-cell recording. 2. Under physiological conditions Ip is an outward current. Experimental conditions which cause a less negative free energy of intracellular ATP hydrolysis (delta GATP) and steeper sarcolemmal gradients for the pumped Na+ and Cs+ ions evoked an Ip in the inward direction over a wide range of membrane potentials. The reversal of the Ip direction was reversible. 3. The inwardly directed Ip increased with increasingly negative membrane potentials and amounted to -0.13 +/- 0.03 microA cm-2 (mean +/- S.E.M.; n = 6) at -95 mV. 4. The reversal potential (Erev) of Ip was studied as a function of delta GATP at constant sarcolemmal gradients of the pumped cations. 5. In order to vary delta GATP the cell interior was dialysed with patch pipette solutions containing 10 mM ATP and different concentrations of ADP and inorganic phosphate. The media were composed to produce delta GATP levels of about -58, -49 and -39 kJ mol-1. 6. A less negative delta GATP shifted Erev to more positive membrane potentials. From measurements of Ip as a function of membrane potential Erev was estimated to be -195, -115 and -60 mV at delta GATP levels of approximately -58, -49 and -39 kJ mol-1, respectively. The calculated Erev amounted to -224 mV at delta GATP approximately -58 kJ mol-1, -126 mV at delta GATP approximately 49 kJ mol-1 and -24 mV at delta GATP approximately -39 kJ mol-1. 7. Possible reasons for the discrepancy between estimated and calculated Erev values are discussed. 8. Shifting delta GATP to less negative values not only altered Erev but also diminished Ip at each membrane potential tested. The maximal Ip (Ip,max), which can be activated by external Cs+ (Cs+o), decreased under these conditions, whereas [Cs+]o causing half-maximal Ip activation remained unchanged. Similarly, the voltage dependence of Ip activation by Cs+o was unaffected. 9. It is concluded that Erev of Ip varies with delta GATP at constant sarcolemmal gradients of the pumped cations. This agrees with thermodynamic considerations.

Adenosine Triphosphate

[The abrasion resistance of plastic teeth--an in-vitro study].

Resistance against abrasion of premolar plastic teeth on their chewing surfaces was determined using an in vitro test method which approximately simulated oral conditions, as well as contact between antagonists, chewing pressure, biting pressure and chewing motion. The humpy surface of commercially manufactured teeth was levelled by grinding, using the abrasion test machine itself, which resulted in two little plain surfaces. After measuring the size of these surfaces, wear due to abrasion was determined by loss of weight. The commercial products showed different resistances against abrasion, the teeth of Dens-Nobilis and Vitapan, which contain amorphous silica, appeared to be more resistant against abrasion than IPN (Artiplus) and PMMA (Keracryl-7, Planustar, SR-Orthotyp-PE) teeth. Unexpectedly, IPN teeth did not show a higher resistance against abrasion than the PMMA teeth, which were tested in this investigation. Only SR-Orthotyp-PE were significantly worse. Under the prevailing test conditions SR-Orthosit-PE teeth are very little resistant against abrasion, although they contain amorphous silica. Investigations with a raster electron microscope revealed that they are too brittle.

Bite Force

[Polymerization shrinkage of light-hardened composites].

The absolute values of polymerization shrinkage and its time-dependent course were measured for commercially available visible-light-cured composite resins and for composite still under development. About the curing rate of the composites were discussed the influences of the fillers and of the amount of the photoinitiator in the organic matrix.

Composite Resins

[The polymerization shrinkage of composites].

The absolute values of polymerization shrinkage and its time-dependent course were measured for commercially available composite resins and for composite still under development using a new method measuring the linear shrinkage. The influences of the amounts and of the recipes of the reactive monomer were determined. From the curves the working times of the investigated composite resins were evaluated.

Biomechanical Phenomena