PubMed Health⌕ Search

Biomedical subjects

A Tondini

Publications and source records attributed to A Tondini.

3 recordsLinked to original sources

Ultrafast three-dimensional ultrasound: application to carotid artery imaging.

BACKGROUND AND PURPOSE: Three-dimensional (3-D) vascular ultrasound can be expected to improve qualitative evaluation of vessel pathology and to provide quantitative data on vascular morphology and function. The objective of this study was to develop an ultrafast 3-D vascular system and to validate its performance for quantitation of atherosclerosis and assessment of regional arterial distensibility. METHODS: The quantitative analysis of focal atherosclerotic lesions was validated in vitro on 27 phantoms of fibroadipous plaques of known volume (range, 100 to 600 mm3). In vivo reproducibility of plaque volume measurement was tested in 33 patients who had a total of 47 predominantly fibroadipous carotid plaques. Distensibility assessment was validated indirectly through the evaluation of age-related changes in distensibility of common carotid artery in healthy and hypertensive subjects (25 men in each group). RESULTS: The volume of plaque phantoms measured from the 3-D data set showed a very close correlation with the true volume (r=0.99; y=0.96x+12.38; P<0.01), with the mean difference between the 2 measurements being -3.12+/-15.1 mm3. High reproducibility was found for measurement of carotid plaque volume in vivo: the mean difference between measurements from 2 observers for the same data set was 0.60+/-11.2 mm3. Indexes of arterial distensibility decreased with age in healthy population, whereas this relationship was lost in hypertensive subjects. CONCLUSIONS: Ultrafast 3-D ultrasound imaging of carotid artery demonstrates good accuracy and reproducibility for atherosclerotic plaque volume measurements. The system also allows the study of age-related degenerative vascular changes.

Aged↗

Nearly real-time visualization of arbitrary two-dimensional sections from three-dimensional acquisition.

This work presents a system for the reconstruction of cross-sections with arbitrary orientations derived from three-dimensional (3D) echographic scanners. The interest for this powerful diagnostic tool has prompted us to develop a low-cost processing board that inserts easily into a stand-alone echograph. The proposed system is able to reconstruct high-resolution cross-sections at one frame per second with a time lag of about 60 s due the 3D acquisition process. The board, based on three pipelined DSP devices, has been designed to process volumetric data collected with a commercial echograph by means a rotating probe synchronized with the ECG signal. The resolution of the reconstruction algorithm implemented on the processing unit has been evaluated both with synthetic 3D data and with experimental data from a phantom.

Animals↗