Larger diameter bearings reduce wear in metal-on-metal hip implants.

Metal-on-metal hip arthroplasty has the longest clinical history of all total arthroplasties. We asked whether large diameter femoral heads would result in less wear than those with small diameters. We also asked if there is a threshold diameter that ensures good wear behavior. We tested three batches of cast high-carbon cobalt-chromium-molybdenum hip implants (28 mm, 36 mm, and 54 mm diameters) in a hip simulator for 5 million cycles. We used bovine serum as lubricant and weighed the samples at regular intervals during testing. The 28-mm configuration had almost twice the wear of the 54-mm configuration, but we observed no difference between the 36-mm and the 54-mm configurations. The similarity in the wear performances of the larger configurations supports the presence of a threshold diameter that ensures good wear behavior.

Femur Head↗

Determination of crystallinity and crystal structure of Hylamer polyethylene after in vivo wear.

Hylamer polyethylene is a crystalline form of polyethylene of 70% crystallinity whereas conventional polyethylene (PE) has 50% crystallinity. Crystallinity is the percentage by weight of the crystalline phase present in the whole polymer, which comprises both amorphous and crystalline phases. Clinical experience has shown that Hylamer components used in joint prostheses, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which leads to osteolysis. The authors have analyzed the crystallinity of polyethylene liners removed from seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening, using Raman spectroscopy coupled with partial least squares (PLS) analysis. The results have been compared to those of two controls who had received Hylamer polyethylene implants sterilized by gamma irradiation in a nitrogen atmosphere. The crystal structure of wear particles released into the tissues from the Hylamer liners sterilized by gamma rays in air is also studied. The materials undergoing two different types of sterilization methods show different crystallinity values (71.50 vs. 69.43), but the crystallinity do not change according to wear (worn and unworn liner region). Both monoclinic and orthorhombic phases are present in the liner, while in wear debris prevalently monoclinic crystals are found in both types of sterilized liners. Different crystallinity rates can explain different wear rates observed in vivo.

Aged↗

Advanced nanocomposite materials for orthopaedic applications. I. A long-term in vitro wear study of zirconia-toughened alumina.

The use of ceramic-on-ceramic (alumina- and zirconia-based) couplings in hip joint prostheses has been reported to produce lower wear rates than other combinations (i.e., metal-on-polyethylene and ceramic-on-polyethylene). The addition of zirconia into an alumina matrix (zirconia-toughened alumina, ZTA) has been reported to result in an enhancement of flexural strength, fracture toughness, and fatigue resistance. The development of new processing routes in nonaqueous media has allowed to obtain high-density ZTA nanocomposites with a very homogeneous microstructure and a significantly smaller and narrower particle-size distribution of zirconia than conventional powder mixing methods. The aim of the present study was to set up and validate a new ZTA nanocomposite by testing its biocompatibility and wear behavior in a hip-joint simulator in comparison with commercial alumina and experimental alumina specimens. The primary osteoblast proliferation onto ZTA nanocomposite samples was found to be not significantly different from that onto commercial alumina samples. After 7 million cycles, no significant differences were observed between the wear behaviors of the three sets of cups. In this light, it can be affirmed that ZTA nanocomposite materials can offer the option of improving the lifetime and reliability of ceramic joint prostheses.

Aluminum Oxide↗

A case report of fracture of ceramic head in total hip arthroplasty: histological and biochemical features of perimplant tissues.

The authors analyzed the case of a patient with a non-cemented hip prosthesis with a ceramic-ceramic coupling. As a consequence of trauma the head fractured. Although the patient could feel the joint grinding, there was no pain and he continued daily living activities for nearly six months, which led to marked wearing of the ceramic head. SEM analysis with microprobe showed 'planed' surfaces on the ceramic head, suggesting repeated movements between the fractured components. Inside the cone of the head, signs of TiAlV, which is an alloy of the prosthetic stem, could be seen. Periprosthetic tissues were packed with ceramic wear particles of sizes ranging between 0.2 and 10 microns, according to the harvest site. Metal and mixed particles were also found. IL1, IL6, IL8 and IL10 assays in the synovial liquid confirmed the inflammatory state and a modest induction of bone resorption, which was less than that observed in patients with loosened metal-polyethylene couplings. The humoral picture was compatible with the radiological aspect, which did not show marked signs of bone resorption. In revision surgery both ceramic components were replaced by a metal head and polyethylene liner. The clinical outcome after 12 months was very good.

Alloys↗

The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints.

Various studies report a weak correlation between the average surface roughness R(a) of metallic ballheads and the observed wear rate of the polyethylene cups coupled to them. The aim of this study is to verify, with controlled in vitro experiments, whether other parameters such as the total roughness R(t), and the skewness R(sk) are better predictors of the polyethylene wear when the metallic heads present a surface conditioning that varies substantially from specimen to specimen, as is usually the case with retrieved specimens. Twelve CoCrMo (cobalt-chromium-molybdenum) ballheads were intentionally damaged in order to reproduce a wide spectrum of surface conditioning and were then subjected to the standard wear test against polyethylene cups, using a hip joint wear simulator. After 2 x 10(6) cycles the weight lost by the cups was assessed with a gravimetric procedure, and the surface roughness of the metallic ballheads was qualified in terms of R(a), R(t), and R(sk). The various parameters were correlated to the weight loss using a linear regression analysis. The skewness R(sk) showed a coefficient linear regression R2 = 0.80, while the average roughness R(a), used in most previous studies, presented an R2 = 0.56. It was concluded that when specimens with substantially different surface conditioning are compared, as in retrievals analysis, it is also important to report the skewness R(sk) so that qualify the surface roughness of the specimens can be qualified.

Coated Materials, Biocompatible↗

Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques.

Hylamer polyethylene was introduced in the 1990s as an alternative to conventional polyethylene. Its chemical and physical properties, and especially its high crystallinity, were claimed to improve resistance to wear. Initially Hylamer devices were sterilized by gamma radiation in air, then the technique was changed and gamma radiation was performed in the absence of oxygen. Clinical experience has shown the early loosening of some devices made from Hylamer. The aim of this study was to ascertain whether early wear and consequent osteolysis was linked to the sterilization method. We retrospectively compared 31 patients with hip prostheses with Hylamer liners sterilized by gamma radiation in air (group 1) with 30 patients with the same prosthesis, but sterilized in the absence of oxygen (group 2). The groups were similar for sex, age, disease, head diameter and material. Mean follow-up was 84 months and no clinical signs of failure were present. Radiographic measurement revealed that wear of group 1 was significantly greater than that of group 2 (0.23 mm/year vs 0.09 mm/year, p=0.001). Periacetabular and femoral osteolysis in group 1 was significantly greater than group 2. In conclusion, the method of sterilization might have influenced the outcome of Hylamer polyethylene liners.

Arthroplasty, Replacement, Hip↗

Device to measure intra-operatively the primary stability of cementless hip stems.

The primary stability of cementless prostheses is critical for the long-term outcome of the operation. Surgeons are currently driven only by their experience in evaluating the extent of stem stability achieved. The aim of the present work was to develop a new device that enables the stability of a cementless stem to be quantitatively assessed intraoperatively. The angle of the stem/femur rotation under torsion and the torque are acquired and compared in real-time to a pre-set threshold inferred from the literature. The device indicates whether the stem is stable or not. It was extensively tested and finally validated in vitro on cadaveric and composite femurs hosting different sizes of the same kind of prostheses, implanted with different levels of press-fitting. The overall accuracy (23%) takes into account not only the overall measurement error but also the variability due to differences in bone quality and stem press-fitting. This error was deemed sufficient to discriminate between stable and unstable implants.

Arthroplasty, Replacement, Hip↗

Structural allograft and primary press-fit cup for severe acetabular deficiency. A minimum 6-year follow-up study.

Between October 1992 and December 1996, 23 patients with pelvic bone stock deficiency involving major columns underwent revision surgery with a cementless press-fit cup and a structural bone graft. Twenty cases were followed up for a minimum of 6 (average 7.6, range 6-11) years. Three cups were revised: one for aseptic loosening, one for septic loosening, and one for recurrent dislocation. At latest follow-up, the average Merle d'Aubigne hip score improved from 10.9 to 16.2; four hips were rated excellent, seven very good, three good, two fair, and one poor. All cups were stable; the grafts were integrated and anatomy was restored. The Kaplan-Meier cumulative probability of not having revision for loosening at 11 years, predicted a survival rate of 84.4%. We are confident that these results are satisfactory for a very demanding procedure.

Adult↗

Evaluation of achievable registration accuracy of the femur during minimally invasive total hip replacement.

The aim of the paper was to investigate whether accurate, point-based registration of the intra-operative femur will be achieved within the context of minimally invasive surgery for total hip replacement. Computer tomography images, collected for pre-operative planning purposes, were used to simulate the intra-operative registration procedure using algorithms for various levels of measurement noise, different small areas of the femur available to the surgeon, and a limited number of collected data points (20-60). This helped with the choice of design variables to perform in vitro registration on a plastic bone model to validate the procedure, which included a multistart algorithm developed for intra-operative registration. The algorithm minimised the distance between the measured and image-derived surfaces and was able to cope with the presence of multiple local minima given sufficient computational effort, even with realistically large measurement noise. It was found that, if a small patch of the femur was used, accessible by a needle that could at times penetrate thin layers of soft tissue, errors in the order of 1.0 mm in translation and 0.5 degrees in rotation were achievable.

Algorithms↗

Isolation and characterization of wear debris generated in patients wearing polyethylene Hylamer inserts, gamma irradiated in air.

Hylamer polyethylene was used in the early 1990s to make hip-joint components. Clinical experience has shown that these components, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which then leads to osteolysis. The authors analyzed polyethylene wear particles in seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening. The results were compared to those of six controls, who had received traditional polyethylene implants, sterilized by the same method. The frequency distribution of globular and fibrillar particles was similar in both groups (38.5% in Hylamer, 45.2% in controls). The globular particles in the Hylamer samples had a mean area of 0.12 microm2, which was significantly lesser than that of the controls (0.30 microm2). The width of fibrillar particles in the Hylamer samples was significantly lesser than that of the controls. Therefore, the two materials, despite undergoing the same type of sterilization, produced different types of wear, due to their different properties. In conclusion, the difference in the morphology of Hylamer polyethylene wear particles in comparison with PCA might have caused a more intensive biological response, early and massive osteolysis, and therefore, early loosening.

Aged↗

Modelling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods.

The long-term fixation of cemented femoral components may be jeopardised by the presence of a fibrous tissue layer at the bone-cement interface. This study used both experimental and finite element (FE) methods to investigate the load transfer characteristics of two types of cemented hip replacements (Lubinus SPII and Müller-Curved) with a fibrous tissue layer. The experimental part investigated six stems of each type, where these were implanted in composite femurs with a specially selected silicone elastomer modelling the soft interfacial layer. Two fibrous tissue conditions were examined: a layer covering the full cement mantle, representing a revision condition; and a layer covering the proximal portion of the cement mantle, representing a non-revised implant with partial debonding and fibrous tissue formation. The FE method was used to model the full fibrous tissue layer condition, for both implants. The layer was modelled as a homogeneous, linearly isotropic material. A cross-comparison was performed of the experimental and FE findings. Agreement between experimental and FE models was verified to be within 15%. Varying the stiffness parameter of the FE soft tissue layer had little influence on the cortical bone strains, though had considerable effect on the cement strains. Stress shielding occurred for both stems under both fibrous tissue conditions, with the greatest reduction around the calcar. However, the cortical bone strains were generally larger than those for the equivalent well-fixed stems. The fibrous tissue layer was not found to increase the general strain pattern of the cement mantle, though localised regions of high stress were detected.

Arthroplasty, Replacement, Hip↗

Sodium-azide versus ProClin 300: influence on the morphology of UHMWPE particles generated in laboratory tests.

Ultra-high molecular-weight polyethylene (UHMWPE) has been used in total joint replacement for the last three decades and is currently the best polymer available for this use. Nevertheless, the wear of UHMWPE remains a serious clinical problem. Polyethylene wear debris has been identified as a cause of osteolysis and a major factor reducing the life of the total hip arthroplasty. Debris generated at the articular surfaces enters the periprostethic tissue where it is phagocyted by macrophages. Studies have shown that particles in the 0.1-10microm size range are particularly important in causing adverse cellular reactions resulting in osteolysis. The morphology, size, mass, and number of wear particles produced in a hip joint simulator are influenced by the tribological conditions used during the experiment. This paper shows that the morphology of the UHMWPE particles generated in vitro is influenced by the type of lubricant used. This study compared, quantitatively and qualitatively, particles generated in vitro using bovine calf serum as lubricant with two different preservatives: sodium azide and ProClin 300. No significant difference was observed with regards to wear between the two types of lubricant used. Quantitative analysis of the wear particles showed that particles generated in serum with sodium azide were not [corrected] morphologically different from those produced in serum with ProClin 300 [corrected]

Animals↗

An easy technique to digest and isolate UHMWPE wear particles from a hip joint simulator.

The size and morphology of polyethylene wear particles isolated from in vitro tests were analysed in this study. There are some major controversies emerging in the literature that will only be resolved by careful particles analysis. Since it is difficult to identify the factors that affect size and morphology of the wear particles, the goal of this study was to compare four different polymer wear debris isolation techniques (base method and acid treatment) under identical conditions in a hip joint simulator to obtain polyethylene wear particles. We investigated achieving particulate isolation by using a different approach to the one reported in the literature that involved an easier and streamline method of particle debris isolation. The new method, compared to the previous one, used a strong base, normal centrifugation, and filtration to digest the serum constituents thus isolating the polyethylene particle debris from lubricant. In all four methods the isolation involved some or all of the following steps: density gradient separation, centrifugation or ultracentrifugation, and washing. However, a requirement for all these techniques was that the lubricant had to be devoid of organic compounds in order to effectively image and count the particle debris. The results from these studies clearly show that this new method of particle isolation is easier and more streamlined than the three methods analysed and reported in literature because it did not involve ultracentrifugation and is quicker.

Arthroplasty, Replacement, Hip↗

The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols.

Ultra-high molecular-weight polyethylene (UHMWPE) has been used in total joint replacement for the last three decades. Despite the recent advancements in prosthesis design, the wear of UHMWPE remains a serious clinical problem; the release of wear debris may induce osteolysis and implant loosening. Controlling the quality of the polyethylene is essential to improve its wear resistance and any potential adverse effect caused by processing, manufacturing or sterilisation should be avoided. To evaluate the influence of the sterilisation method (gamma-irradiation and ethylene oxide (EtO)-treatment) and third-body particles, gamma- and EtO-sterilised UHMWPE acetabular cups were tested against CoCrMo femoral heads in a hip joint simulator run for 2.5million cycles in bovine calf serum in the presence of third-body polymethylmethacrylate (PMMA) particles. A method not requiring ultra-centrifugation has been proposed for the isolation of polyethylene wear debris from the serum lubricant. SEM analysis allowed debris shape and morphology to be determined, and the wear mechanism operating in this study to be hypothesised. The morphological features of the wear debris were in agreement with clinical findings, enabling the hip simulator function to be validated. Micro-Raman spectroscopy coupled to PLS analysis showed that the mechanical friction during in vitro tests induced significant crystallinity changes in all the cups. The most significant changes were observed for the EtO-sterilised cups, which showed the highest weight loss.

Animals↗

Experimental investigation of bone remodelling using composite femurs.

OBJECTIVE: To determine the load transfer patterns of femurs in the intact, immediate post-operative and long-term (remodelled) post-operative implanted conditions for Lubinus SPII and Müller-Curved cemented hip prostheses, and to examine to what extent remodelling may influence the long-term outcome. DESIGN: Experimental and finite element (FE) methods were applied to composite femurs under loads representing the heel-strike phase of gait, determining cortical bone and cement strains for the different femur conditions. BACKGROUND: The authors previously developed protocols to measure bone and cement strains, and to produce remodelled femur specimens, yet these have not been applied together to compare strain patterns of different femur conditions. The Lubinus SPII is clinically more successful than the Müller-Curved stem, with failure mainly due to aseptic loosening. METHODS: Cortical bone strains were determined in intact femurs. Six femurs each were implanted with the two stem types and cortical bone and cement strains were measured. Bone remodelling was recreated using a validated CAD-CAM procedure to remove a layer of proximal cortical bone, replicating a typical scenario found in stable clinical retrievals. Strains were remeasured. FE methods were used to compliment the experiments. RESULTS: Stress shielding was reduced with remodelling, though bone strains did not return to their intact values, particularly around the calcar. Cement strains increased with remodelling. Differences occurred between the two stems; the Müller-Curved produced a more severe strain transition. CONCLUSIONS: Procedures were successfully combined together to investigate in vitro the performance of two cemented stems, in immediate and long-term post-operative conditions. The increase of cement strains with remodelling is a potential indicator for in vivo cement failure. RELEVANCE: The consequences of femoral bone remodelling on the long-term success of joint replacements are not well understood, where remodelling may lead to increased bone and cement stresses.

Bone Remodeling↗

CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning.

The present study is aimed to compare accuracy and the repeatability in planning total hip replacements with the conventional templates on radiographs to that attainable on the same clinical cases when using CT-based planning software. The sizes of the cementless components planned with new computer aided preoperative planning system called Hip-Op and with standard templates were compared to those effectively implanted. The study group intentionally included only difficult clinical cases. The most common aetiology was congenital dysplasia of hip (65.6%). The Hip-Op planning system allowed the surgeons to obtain a preoperative planning more accurate than with templates, especially for the socket. Assuming correct a size planned one calliper above or below that implanted the accuracy increased from 83% for the stem and 69% for the socket when using templates to 86% for the stem and 93% for the socket when using the Hip-Op system. The repeatability of the Hip-Op system was found comparable to that of the template procedure, which is much more familiar to the surgeons. Furthermore, the repeatability of the preoperative planning with the Hip-Op system was consistent between surgeons, independently from their major or minor experience. The study clearly shows the advantages of a three-dimensional computer-based preoperative planning over the traditional template planning, especially when deformed anatomies are involved. The surgical planning performed with the Hip-Op system is accurate and repeatable, especially for the socket and for less experienced surgeons.

Arthroplasty, Replacement, Hip↗

The muscle standardized femur: a step forward in the replication of numerical studies in biomechanics.

The standardized femur is the computer aided design (CAD) solid model of a synthetic human femur, commonly used in experiments in vitro, available in the public domain through the International Society of Biomechanics Finite Element Mesh Repository. Currently used by hundreds of researchers, it was made available to simplify the experimental cross-validation of numerical studies as well as their replication by other researchers. One aspect that the standardized femur left uncovered is the definition of muscles and ligaments. In particular, for a variety of simulations it would be extremely useful to map on to the femoral surface the insertion of the principal muscles. The aim of the present study was to create a new solid model, called the muscle standardized femur, where the femoral insertion of each muscle is mapped on to the surface of the femur. Published data on muscle insertion morphometry were registered to the model by applying an affine scaling defined on bone landmarks. Good agreement was found with another similar study in which only the insertion centres were defined. The new model will be made available in the public domain for no-profit uses. When combined with published data on the direction and intensity of muscular forces this model is expected to make a useful contribution to the steadily growing library of models and data sets made available to the biomechanical community.

Anatomy, Cross-Sectional↗

Mechanical strength of a femoral reconstruction in paediatric oncology: a finite element study.

In 1997 the proximal femur of a four-year-old child affected by a Ewing sarcoma was reconstructed using a massive bone allograft in conjunction with a vascularized fibula autograft. During the first three years of follow-up the reconstruction underwent important morphological changes. The aim of the present study was to evaluate the risk of fracture of the reconstructed proximal femur, once the physiological loads are restored, associated with a short, slow but unprotected level walk. Subject-specific finite element models of the operated femur, and of the intact contralateral one, were generated from a computed tomography exam, taken for routine clinical monitoring at month 33 of follow-up. The material properties were mapped on to the mesh and a loading condition comprising the hip joint reaction and the abductor muscle force was simulated. The risk of fracture was locally estimated, for the operated and intact femur, using the ratio between the bone tissue strength and the predicted Von Mises equivalent stress, taking into account the different behaviours of the bone tissue in tension or compression. The results showed that although the fibula grew dramatically during follow-up, the reconstructed femur had not recovered the whole mechanical strength of a normal femur. The reconstructed femoral neck seemed to be weaker than the contralateral one and hence at a higher fracture risk. However, no region reached the failure limit, so the model predicted no fracture of the femur if a short, slow but unprotected walk were allowed. The model predictions found an indirect clinical validation when the child was allowed to perform short unprotected walks and did not experience any fracture.

Bone Transplantation↗