PubMed Health⌕ Search

Biomedical subjects

A V Lakshminarayanan

Publications and source records attributed to A V Lakshminarayanan.

At least 19 recordsLinked to original sources

Automatic exposure control for a slot scanning full field digital mammography system.

Automatic exposure control (AEC) is an important feature in mammography. It enables consistently optimal image exposure despite variations in tissue density and thickness, and user skill level. Full field digital mammography systems cannot employ conventional AEC methods because digital receptors fully absorb the x-ray beam. In this paper we describe an AEC procedure for slot scanning mammography. With slot scanning detectors, our approach uses a fast low-resolution and low-exposure prescan to acquire an image of the breast. Tube potential depends on breast thickness, and the prescan histogram provides the necessary information to calculate the required tube current. We validate our approach with simulated prescan images and phantom measurements. We achieve accurate exposure tracking with thickness and density, and expect this method of AEC to reduce retakes and improve workflow.

Absorptiometry, Photon↗

An adaptable head retention and alignment device for computed tomography scanning of Macaca mulatta.

An adaptable retention device has been developed for the purpose of holding and aligning the head of a sedated primate subject during computed tomography (CT) scan procedures. The device is used to obtain a close reproduction of CT scan studies at a time before and after dental implant placement in the mandibles of nine subjects. Geometric and material properties are extracted from these studies for the purpose of developing finite elements computer models. The device is constructed of low-density acrylic and consists of a horizontal base to which lateral supports are affixed. The device is placed on the CT table and axially aligned with the scan beam. Repeatable, calibrated CT studies of primate implant subjects were possible using the head holding device.

Acrylic Resins↗

Temporomandibular joint sounds and condyle/disk relations on magnetic resonance images.

This study compared the condyle/disk relationships on magnetic resonance images (MRIs) in a group of subjects with completely silent temporomandibular joints (TMJ) when tested clinically with those in subjects with readily discernible TMJ sounds. The sounds were recorded with an accelerometer as the transducer. Selected degrees of jaw separation were electronically determined and recorded with interocclusal wafers for use with the imaging process. Of the "silent joints" 89% were found to have sounds when tested with the accelerometer. These "subclinical" sounds tended to be of shorter duration and occurred at a greater degree of vertical opening than the clinically discernable sounds. The MRIs of the group with clinically discernable sounds tended to show a change in the relationship between the head of the condyle and the intermediate zone of the disk, at the degree of jaw separation of the sound occurrence, whereas no condyle/disk change occurred in the group with "clinically silent joints." It is likely that all joints create sound during function. The different characteristics of the subclinical sounds versus the clinical sounds may indicate differing sound origins.

Adult↗

Self-masking subtraction tomosynthesis.

The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation.

Computers↗

Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms.

A new technique is proposed for the mathematical process of reconstruction of a three-dimensional object from its transmission shadowgraphs; it uses convolutions with functions defined in the real space of the object, without using Fourier transforms. The object is rotated about an axis at right angles to the direction of a parallel beam of radiation, and sections of it normal to the axis are reconstructed from data obtained by scanning the corresponding linear strips in the shadowgraphs at different angular settings. Since the formulae in the convolution method involve only summations over one variable at a time, while a two-dimensional reconstruction with the Fourier transform technique requires double summations, the convolution method is much faster (typically by a factor of 30); the relative increase in speed is larger where greater resolution is required. Tests of the convolution method with computer-simulated shadowgraphs show that it is also more accurate than the Fourier transform method. It has good potentialities for application in electron microscopy and x-radiography. A new method of reconstructing helical structures by this technique is also suggested.

Computers↗

MR imaging of the vocal tract during vowel production.

Modeling of vocal tract behavior during speech production requires accurate measurements of the entire vocal tract. To accomplish this, magnetic resonance (MR) imaging was performed on a 0.5-T system with a custom-made, double-loop, wrap-around coil. A midsagittal section of the region from the glottis to the lips was imaged during sustained production of five American English vowels. A gradient-spoiled gradient-echo sequence was used to achieve a 4-second imaging time. Images showed clear profiles of the entire vocal tract and exhibited essential articulatory features of vowel production. It was possible to measure midsagittal widths at various points along the vocal tract with 1-mm resolution. The measurements were used to construct a tube model for prediction of the acoustic output of the vocal tract. It is concluded that risk-free MR imaging promises to be an important means of acquiring data for vocal tract modeling, with applications to speech pathology, linguistics, and artificial speech.

Humans↗