PubMed Health⌕ Search

Biomedical subjects

A V Lombardi

Publications and source records attributed to A V Lombardi.

At least 19 recordsLinked to original sources

Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty.

A series of 120 primary total hip arthroplasties with minimal 10-year follow-up, in which a cementless, proximal-to-distal, dual-tapered geometry femoral component was used, was reviewed. At a mean follow-up interval of 12.20 years, a mean Harris hip score improvement of 38 points was calculated. Three (2.5%) femoral components were revised secondary to aseptic loosening, yielding a 97.5% survivorship. Thigh pain was mild or absent in 96.6% of the cases. Distal femoral osteolysis was observed in <2% of cases. The Harris hip score improvement, low incidence of severe thigh pain, high survivorship, and low incidences of significant stress shielding and distal osteolysis suggest excellent long-term results with the use of this uncemented tapered design, adding credence to the design rationale and justifying its continued use.

Adult↗

Short-term results of the M2a-taper metal-on-metal articulation.

A polyethylene-free, metal-on-metal acetabular system (M2a-taper [Biomet, Inc., Warsaw, IN]) was designed in an effort to improve total hip arthroplasty (THA) longevity. Minimum 2-year follow-up results involving 72 polyethylene liner THAs and 78 metal liner THAs from a multicenter, randomized, controlled, investigational device exemption study are reported. Mean Harris hip scores of 95.54 (polyethylene liner group) and 95.23 (metal liner group) were reported at mean follow-up intervals of 3.29 and 3.23 years. Radiographic evaluation revealed no evidence of early failure. No acetabular components have been revised or are pending revision. No statistically significant differences in the data were calculated between liner types except for the immediate postoperative (P=.0415) and minimum 2-year follow-up (P=.0341) angles of inclination. The M2a-taper metal-on-metal articulation may represent a viable alternative for THA in younger, higher demand patients.

Adolescent↗

An algorithm for the posterior cruciate ligament in total knee arthroplasty.

The fate of the posterior cruciate ligament in primary total knee arthroplasty is controversial. An algorithmic approach is presented that is based on pathologic criteria for evaluating and treating patients with primary total knee arthroplasty that will aid in the posterior cruciate ligament decision-making process, producing more predictable procedures and outcomes. A consecutive series of the first 120 patients (171 knees) who had primary posterior cruciate-retaining arthroplasty and the first 120 patients (180 knees) who had primary posterior-stabilized arthroplasty with a minimum 5-year followup in which the Maxim Complete Total Knee System and the algorithmic approach were used were compared. No statistically significant differences in outcome between the groups were observed. Among the patients who had posterior cruciate-retaining arthroplasty, no revisions attributable to aseptic loosening have been reported at an average followup of 6.39 years. The average followup Knee Society total score was 162.16 points, with 91 (54.8%) knees having excellent outcome ratings. No revisions attributable to aseptic loosening have been reported among the patients who had posterior-stabilized arthroplasty at an average followup of 5.98 years. The average followup Knee Society total score was 158.05 points, with excellent outcome ratings reported in 96 (54.9%) knees. The use of a standardized algorithm has streamlined the treatment of patients having primary total knee arthroplasty, consistently providing excellent clinical results when either retaining or sacrificing the posterior cruciate ligament.

Adult↗

Simultaneous bilateral total knee arthroplasties: who decides?

The purpose of the current retrospective review was to compare the results of 1498 patients having 1090 simultaneous bilateral total knee arthroplasties and 958 unilateral total knee arthroplasties in a 3-year period, focusing on perioperative complications, length of hospital stay, and discharge disposition. Gender, age, diagnosis, and weight were similar between the groups. Patients undergoing simultaneous bilateral total knee arthroplasties had statistically significant higher amounts of intraoperative blood loss, with more patients requiring blood transfusion, and a higher average number of units of blood transfused compared with patients undergoing unilateral total knee arthroplasty. Overall, a significantly higher incidence of gastrointestinal complications was reported in patients who had simultaneous bilateral knee arthroplasties compared with patients who had unilateral knee arthroplasty. Comparing age subgroups within the unilateral group revealed significantly higher incidences of pulmonary, neurologic, cardiac, and genitourinary complications among patients 80 years or older versus patients younger than 80 years. Patients having simultaneous bilateral arthroplasties who were 80 years or older had significantly higher incidences of pulmonary, neurologic, and cardiac complications than patients younger than 80 years in that same group. These results suggest that age, not procedure, has a more significant role in the perioperative morbidity of total knee arthroplasty. Based on the results from the current study and previous literature documenting patient preference, patient satisfaction, efficacy, and outcomes comparable with those of patients having unilateral total knee arthroplasty, the authors continue to offer patients the option of simultaneous bilateral total knee arthroplasties.

Aged↗

An in vivo determination of total hip arthroplasty pistoning during activity.

The purpose of this study was to determine to what extent hip joint separation occurs during normal gait on a treadmill and an abduction/adduction leg-lift maneuver in patients who have undergone total hip arthroplasty (THA). Eight patients who had a total of 10 successful unconstrained THAs (Harris Hip Scores >90) performed successive gait motions on an electronically powered treadmill and an abduction/adduction leg lift while under fluoroscopy. The fluoroscopic video images were analyzed using a 3-dimensional model-fitting technique that converts 2-dimensional fluoroscopic images into 3-dimensional real-time images. Hip joint separation was determined to be present if the amount of separation was >0.75 mm, the calculated linear error. During both activities, all 10 THAs experienced femoral head/acetabular component separation. For gait, the maximum amount of separation was 2.8 mm, while the minimum amount was 0.8 mm (average, 1.2 mm). For abduction/adduction leg lift, the maximum amount of separation was 3.0 mm, while the minimal amount was 1.7 mm (average, 2.4 mm). It appears that the femoral head separates from the acetabular component but remains in contact with the superior-most tip of the component. Potential detrimental effects resulting from hip joint separation include premature polyethylene wear and component loosening. Wear may be enhanced because of the creation of multidirectional wear vectors or excessive loads resulting from eccentric femoral head pivoting. These data may be valuable in hip simulation studies to better duplicate wear patterns observed in retrieval analysis.

Acetabulum↗

Noncemented acetabular component removal in the presence of osteolysis: the affirmative.

The strategy for retention or removal of the acetabular component to address osteolytic activity is becoming an increasingly debated issue among joint replacement surgeons. It is paramount to the success of the revision surgery to eliminate the particulate debris source and thoroughly debride and graft the periacetabular regions. Visualization and complete access to all periacetabular regions require acetabular component removal. The authors present an opinion on acetabular component removal and introduce an impaction grafting method for addressing periacetabular osteolysis. The intermediate results at an average of 41 months are excellent with one patient requiring rerevision of the acetabular component at 83 months postoperative because of aseptic loosening. The outcome of revision total hip arthroplasty has been shown to be inferior to primary total hip arthroplasty, with each following revision having less probability for success equaling the preceding procedure. However, it is the authors' opinion that removing the entire acetabular component is the most prudent choice to eliminate and to avoid the introduction of adverse variables such as particulate debris and component malposition and nonconformity, which may contribute to the continuation of the osteolytic process.

Acetabulum↗

Dislocation after total hip arthroplasty using the anterolateral abductor split approach.

The three basic surgical approaches used most commonly in total hip arthroplasty are transtrochanteric, posterior, and anterolateral. Complications related to each of these surgical approaches have been reported including dislocation, trochanteric nonunion, heterotopic ossification, neurovascular damage, postoperative limp, and implant malalignment. The anterolateral abductor split approach previously has been reported to allow ease of access into the hip joint, optimum joint visualization, protection of neurovascular structures of the hip, and predictable results for postoperative hip function restoration. Reviewing a large consecutive series of primary total hip arthroplasty cases (1518), the authors report an overall dislocation rate less than 1% (12:1518; 0.79%). Stratified by preoperative diagnosis, patients undergoing total hip arthroplasty after trauma, or presenting with congenital dysplastic hip are at the highest risk for postoperative dislocation. Primary total hip arthroplasty using the anterolateral, abductor split approach can minimize the rate of postoperative dislocation in the prevailing preoperative diagnostic categories.

Adult↗

Freehand resection of the patella in total knee arthroplasty referencing the attachments of the quadriceps tendon and patellar tendon.

A freehand technique of patellar resurfacing using anatomic references was prospectively evaluated. This technique utilizes an osteotomy beginning at the inferior pole of the patella just posterior to the insertion of the patellar tendon and is carried proximally posterior to the insertion of the quadriceps tendon. Evaluation of 55 total knee arthroplasties in 41 patients showed an average restored patellar thickness within 0.1 mm. The overall patellar thickness was restored to within 1 mm of its preoperative thickness in 50 (91%) of 55 knees. Patellar tilt was equal to or less than 4 degrees in 42 (89%) of 47 arthroplasties evaluated radiographically. The patellar thickness averaged 17.9 mm, well above the critical value of 15 mm reported in the literature.

Adult↗

Particulate debris presenting as radiographic dense masses following total knee arthroplasty.

Two cases of failed total knee arthroplasty associated with significant titanium debris that created massive radiographic densities are reported. The similarities of the failed total knee arthroplasties are that both involve titanium femoral components with failed metal-backed patellar components. At the time of surgical intervention, patellar polyethylene dissociation from metal-backed patellar components was noted with excessive burnishing and wear of the remaining metal-backed patellar component and of the titanium femoral component. Wear of the tibial polyethylene was noted in both cases. The titanium-on-titanium wear couple produced significant debris, resulting in large mass formation about the total knee arthroplasty. Additionally, there were loculated, fluid-filled sacks of titanium debris. Histologic sections performed for both cases revealed significant deposits of titanium in combination with polyethylene. In both cases, radiographs revealed the presence of large, radiodense masses. These cases illustrate that when considering etiologies for radiodense masses about total joint arthroplasty, particulate titanium debris resulting in mass formation must be added to the differential diagnosis.

Aged↗

Tapered design for the cementless total hip arthroplasty femoral component.

The long-term behavior of total hip arthroplasty ultimately is determined by adaptive bone remodeling. Stress adaptation creating various degrees of metaphyseal bone atrophy has occurred with prostheses designed for tight distal fit and fill. This phenomenon has been explained as bone adaptation resolving the conflict between femoral component stiffness and bone flexibility. However, clinical observations indicate that a different premise may be operational when prostheses with tapered geometries are used. The results of four published reports (748 arthroplasties) using cementless femoral components of a tapered design were reviewed. The review found a low incidence of aseptic loosening (0.5%) and significant thigh pain (0.5%), and a radiographic incidence of proximal bone atrophy of 6%. In no case was the metaphyseal bone atrophy described as severe or extensive. These findings challenge the premise that reactive bone adaptation is related to the issues of femoral component stiffness exclusively and propose that femoral component geometry may have an influence on bone adaptation.

Arthroplasty, Replacement, Hip↗

Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use.

Between 1984 and 1986, 177 nonconsecutive, primary total hip arthroplasties were performed in 150 patients using the Mallory-Head Porous femoral component (Biomet, Warsaw, IN) inserted without cement. Average time to follow-up evaluation for the entire population (including all early revisions) was 76 months (6.3 years). There were 10 revisions (6%) with an average time to revision of 50 months (4.2 years). Two revisions were for component undersizing; three revisions were for aseptic loosening; four revisions were for acetabular component failure and one revision was due to a femoral fracture secondary to trauma. At the most recent follow-up visit, the average Harris hip score for all hips increased from 41.5 before surgery to 86.8 (P < .001). Radiographic assessments yielded an average Engh fixation score of 20.7. The Kaplan-Meier survival estimate for the average time to follow-up evaluation was 0.98. Based on our patient selection criteria and excellent intermediate clinical and radiographic results, the initial design strategies of the Mallory-Head Porous femoral prosthesis have been confirmed.

Adolescent↗

Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty.

In an attempt to study the incidence of intraoperative femoral intercondylar fractures, two large series of posterior-stabilized total knee arthroplasty (TKA) systems were reviewed. Eight hundred ninety-eight nonconsecutive primary posterior-stabilized TKAs were compared with a second nonconsecutive series of 532 posterior-stabilized TKAs. Unique to the secondary TKA system is an intercondylar sizing guide to aid in verification of the intercondylar resection size. In the initial series, 40 distal femoral intercondylar fractures were noted (rate = 1:22; nondisplaced, 35; displaced, 5). In the secondary series, one displaced distal femoral intercondylar fracture occurred (rate = 1;532). The difference in the rate of fracture between the two populations was statistically significant (P<.001). Intraoperative distal femoral intercondylar fracture represents a potential complication of TKA and can be avoided with careful resection technique and size verification. No change in the postoperative rehabilitation program is required, however, for those patients identified with nondisplaced and intraoperative-stabilized displaced distal femoral intercondylar fractures.

Aged↗

Failure of intraoperatively customized non-porous femoral components inserted without cement in total hip arthroplasty.

Seventy-four primary total hip arthroplasties were performed in sixty-eight patients between August 1990 and September 1991. Clinical assessments were made with use of the Harris hip score and, specifically, the pain component of that score. The preoperative radiographs were digitally quantified for calculation of the so-called canal-to-calcar ratio and the so-called cortical index. The postoperative radiographs were evaluated for the percentage of the cross-sectional area of the femoral canal that was occupied by the prosthesis; subsidence of the prosthesis; and adaptive osseous changes, including hypertrophic cortical remodeling, osteolysis, formation of sclerotic radiolucent lines around the prosthesis, and formation of a pedestal at the tip of the prosthesis. The indication for the arthroplasty was osteoarthrosis in fifty hips (68 per cent), avascular necrosis in fourteen (19 per cent), congenital dysplasia in six (8 per cent), and another diagnosis in four (5 per cent). The average duration of follow-up was thirty-one months (range, eleven to forty-six months). The average Harris hip score (and standard deviation) was 75 +/- 16.8 points (range, 29 to 100 points), and the average score for the pain component was 37 +/- 7.5 points (range, 0 to 44 points). The average canal-to-calcar ratio of the hips was 0.44 (range, 0.32 to 0.74), and the average cortical index was 0.54 (range, 0.33 to 0.66). The average subsidence of the component was 0.6 centimeter (range, 0.0 to 2.3 centimeters). The average fill of the canal was 100 per cent proximally, 97 per cent at the middle of the stem, and 92 per cent distally as measured on the anteroposterior radiographs made immediately postoperatively and 100, 95, and 90 per cent, respectively, as measured on the lateral radiographs. A failure occurred in twenty-one hips (28 per cent) in twenty-one patients, with an average time to failure of 21 +/- 13 months (range, one to forty-four months). The Kaplan-Meier survival estimate (and standard error) for this population was 0.45 +/- 0.11 (confidence interval, 0.67 to 0.23) at forty-four months. The average subsidence of the components that failed was 0.7 centimeter (range, 0.1 to 2.3 centimeters). There was no significant relationship between failure of the component and the age or sex of the patient, the diagnosis, or the side of the operation. Postoperative severity of pain (p = 0.09) or subsidence (p = 0.08) alone did not reach significance for predicting outcome. The Harris hip score alone (p = 0.05), the Harris hip score in combination with subsidence of the femoral component (p = 0.01), and the pain component of the Harris hip score in combination with subsidence of the femoral component (p = 0.01) were all significant for predicting outcome. No other measured radiographic variable was predictive of failure. Despite optimization of the fit of the component within the femoral canal and the percentage of the cross-sectional area of the femoral canal occupied by the component, the clinical results indicated a high rate of failure. Thus, these criteria are not the only requisites for stabilization of these femoral components without cement. On the basis of these data, we have discontinued the use of these intraoperatively customized, non-porous, smooth femoral prosthesis.

Activities of Daily Living↗

Dislocation following primary posterior-stabilized total knee arthroplasty.

From 1981 through 1991, 3,032 primary total knee arthroplasties were performed using the Insall-Burstein Posterior Stabilized Condylar Prosthesis (IB-I, IB-II, and IB-II modified) (Zimmer, Warsaw, IN). Fifteen posterior dislocations occurred: 4 with the IB-I system occurring 2 or more years after surgery, 10 with the IB-II system (8 occurring 6 months after surgery and 2 occurring 2-3 years after surgery), and 1 with the IB-II modified system occurring 9 months after surgery. Statistically significant differences for the rate of dislocation between both the IB-I and IB-II modified arthroplasties versus the IB-II arthroplasties were found (P < .001). In an attempt to identify a cause for these dislocations, the authors retrospectively assessed the 15 dislocated cases with respect to sex, age, weight, height, preoperative and postoperative Hospital for Special Surgery scores, preoperative and postoperative alignment, preoperative versus postoperative reconstruction dimensions, patellar thickness and height, and postoperative flexion and compared the results with those patients who did not experience dislocation. Possible etiologies and mechanisms of dislocation were sought. There were no significant differences between the control and study groups for any variable assessed, with the exception of postoperative flexion, which averaged 118 degrees for the study group and 105 degrees for the control group (P < .001). Conservative management was successful in 11 cases. In September 1988 the IB-II system was introduced; modification of the tibial insert was made in January 1990.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗