Prediction of functional outcome by quantification of sestamibi and BMIPP after acute myocardial infarction.

Iodine-123 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) can be used to image myocardial fatty acid regional distribution and utilisation with single-photon emission tomography (SPET). By visual analysis, a mismatching with regional uptake of BMIPP less than that of a perfusion tracer has been shown to predict myocardial viability and functional improvement after restoration of flow in patients with myocardial infarction. The current study aimed to evaluate a newly developed quantitative method of analysis of sestamibi and BMIPP uptake for the prediction of functional recovery after revascularization in patients with acute infarction. BMIPP and gated sestamibi SPET studies at rest were obtained before and >3 months after revascularization in 18 patients with recent infarction. A colour-coded polar map was generated from the comparison of sestamibi and BMIPP uptake. Depending on the relative distribution of the two tracers, different patterns of uptake were identified and their extent expressed as percentages of the surface of the whole left ventricle and of the three main coronary artery territories. At follow-up, recovery was defined as a > or =5% increase in ejection fraction compared with baseline. Receiver-operating characteristic curve analysis was performed to analyse the data. At baseline, significant correlations were found between ejection fraction and the % surface with decreased sestamibi or BMIPP uptake (r=-0.68, P= 0.001, and r=-0.72, P<0.0001, respectively). When combining both tracers, ejection fraction was significantly associated with the extent of myocardium showing decreased sestamibi uptake with lower BMIPP uptake (mismatching; r=-0.68, P=0.001). At follow-up, significant functional recovery was found in 13/18 patients. By ROC curve analysis, the optimal pattern of distribution predicting recovery was a mismatching with uptake of sestamibi <70% and uptake of BMIPP at least 10% lower. For this parameter, optimal cut-off of extent was 10% of the whole left ventricle surface (sensitivity 69%, specificity 80%, accuracy 72%) and 25% of the infarct-related arterial territory (sensitivity 77%, specificity 80%, accuracy 78%). The areas under the curve were 79% for the left ventricle surface and 72% for the individual arterial territories. These results suggest that in patients with acute infarction, quantitative analysis of sestamibi and BMIPP could offer an objective and reproducible method for estimating the severity of cardiac dysfunction and predicting the evolution of ejection fraction after revascularization.

Fatty Acids↗

Validation of the cerebellum as a reference region for SPECT quantification in patients suffering from dementia of the Alzheimer type.

In longitudinal brain studies of dementia of the Alzheimer type (DAT), the cerebellum is often used as a reference region for single photon emission computed tomography (SPECT) quantification, which assumes no significant regional influence of physiological fluctuations or pathology. With the use of absolute quantification in DAT patients, reproducibility of cerebellar uptake of technetium-99m-d,l-hexamethylpropyleneamine oxime (HMPAO) was tested and compared with the mean absolute cerebellar tracer uptake value in DAT patients and healthy control subjects. In 13 DAT patients SPECT studies were repeated within 2 weeks to assess reproducibility of cerebellar regional brain uptake (rBU). With calibrated point sources as scaling factors, cerebellar activity was expressed as rBU of HMPAO per cm3 brain tissue in percent of the injected lipophilic dose of 740 MBq (20 mCi). Also, mean cerebellar rBU in patients suffering from DAT was calculated and compared with a previously established database obtained in healthy volunteers. Repeated SPECT studies within a 2-week interval in clinically stable patients resulted in a mean rBU increase of 6.8 +/- 10.3% in the second SPECT study as compared with the first. A similar shift was previously reported in healthy volunteers. Mean cortical cerebellar rBU values in DAT patients and in the healthy reference population concurred, after cumulative corrections for body surface and for a mean brain volume of 1350 ml (obtained in healthy control subjects), showing respective mean values of 53.9 +/- 7.4 and of 52.0 +/- 7.3 x 10(-6) of the injected lipophilic dose 740 MBq (20 mCi) of HMPAO per cm3 of brain tissue. A unidirectional shift in mean absolute cerebellar uptake values occurs between repeat SPECT examinations in DAT patients similar to previous findings in a group of healthy volunteers. The origin of this phenomenon remains elusive but deserves further study with regard to SPECT (semi)quantification in DAT patients. Most interestingly, the presented findings suggest that with the use of HMPAO SPECT in DAT patients the cerebellum remains scintigraphically uninvolved.

Aged↗

Bone marrow content measured in radioimmune bone marrow scintigraphy: intra- and inter-observer variability.

The aim of this study was to assess the possible quantification of vertebral residual bone marrow content relative to the bone marrow content of a non-irradiated vertebra. This method is based on the vertebral count activity, measured using radioimmune bone marrow scintigraphy. First, however, we had to evaluate intra- and inter-observer variability. In three patients who underwent radioimmune bone marrow scintigraphy, two independent observers measured the count density in 51 (15 lumbar and 36 thoracic) vertebrae using a manually drawn region of interest. To evaluate intra- and inter-observer variability, we calculated the means and standard deviations of the differences between measurements. Bland-Altman plots were drawn for all vertebrae as well as for three subgroups of vertebrae (the upper thoracic spine, D1-D6; the lower thoracic spine, D7-D12; and the lumber spine, L1-L5). For all vertebrae, the mean (+/- S.D.) difference, expressed as a percentage of the overall mean, was -0.44 +/- 3.3% for observer 1 and -0.3 +/- 2.1% for observer 2 for intra-observer variability; inter-observer variability varied from 0.55 +/- 3.9% to 1.28 +/- 3.7%. On the Bland-Altman plots, the data points were evenly distributed above and below the 0-line and the linear regression equations matched the line of equality almost perfectly. This pattern was observed for all the vertebrae as well as for the subgroups of vertebrae. In conclusion, our results show that the intra- and inter-observer variabilities are not great, confirming that this technique is simple and robust and can be used for further quantification of bone marrow content in the axial skeleton.

Adult↗

Quantification of 99Tcm-sestamibi and 123I-BMIPP uptake for predicting functional outcome in chronically ischaemic dysfunctional myocardium.

Little is known about the usefulness of free fatty acid scintigraphy for assessing viability in chronic ischaemic heart disease. To investigate this, we quantified the uptake of 99Tcm-sestamibi and 123I-BMIPP at rest twice within 6 months in 20 patients with chronic ischaemic left ventricular dysfunction and infarction. Four patterns of the relative distribution of both tracers were observed and classified as normal, mismatched, matched and scar. The proportion of the left ventricular surface corresponding to each pattern was expressed as the percentage of the total surface using a polar map. Between the two studies, the patients either underwent revascularization or were treated conservatively. The quantitative results were compared with those of dobutamine stress echocardiography (DSE) in arterial territories with resting contractile dysfunction and correlated with the evolution of regional and global function at follow-up. At baseline, 25 arterial territories were analysed. Using sestamibi, on average one-third of their surface was considered to be normally perfused. No clear association was found between the percent normally perfused surface and the DSE findings. Adding BMIPP and using a value of > 7% of the arterial surface with BMIPP lower than sestamibi (mismatch) as the cut-off for the significance of viability, 14 of 18 mismatched regions were considered viable by DSE, and six of seven with < 7% mismatched surface or matching were not. Fifteen patients were viable, of whom 13 were revascularized (16 territories). At follow-up, global function improved in 11 of the 15 viable patients, all in the revascularized group. Regional improvement was noted in 11 of 16 revascularized territories, and was associated with a significant increase in sestamibi and BMIPP uptake and in the percent normally perfused myocardial surface. In the five patients without significant viability, no functional deterioration or changes in the quantitative parameters were observed during treatment. The results suggest that quantitative analysis of the uptake of sestamibi and BMIPP is a reliable method to objectively assess the presence of myocardial viability in chronic ischaemic heart disease and to predict functional improvement after revascularization.

Aged↗

Normative data for the Boston naming test in native Dutch-speaking Belgian elderly.

A normative study of the 60-item version of the Boston Naming Test (BNT) was performed in a group of 200 native Dutch-speaking Flemish elderly. Analysis of test results revealed that BNT performance in Dutch is significantly affected by age, years of education, and gender. Error analysis disclosed verbal semantic paraphasias to occur as the most frequent error type (1/3 errors). "Don't know responses," verbal semantic paraphasias, and adequate circumlocutions were found on at least 30 different BNT items and constituted the most diffusely distributed error types. Following a careful review of other normative BNT studies, group characteristics rather than cultural differences were found to account for the difference in the overall mean scores. Our study surprisingly revealed that, as far as American-English, Australian-English and Dutch-speaking elderly are concerned, linguistics do not have an impact on the overall mean BNT score. A linguistic impact, however, clearly holds on the qualitative levels of performance, reflected by fundamental differences in the error distribution in different languages. Language-related BNT characteristics therefore stress the need for specific adaptations of norms.

Aged↗

Can we rely on 99Tcm-sestamibi gated tomographic myocardial perfusion imaging to quantify left ventricular function? A comparative study with classical isotopic techniques for the measurement of ejection fraction.

The assessment of left ventricular ejection fraction is an important element in the evaluation of cardiac performance, and one of the most commonly performed tests in nuclear cardiology. The aim of this study was to evaluate the accuracy and reliability of ejection fraction values calculated from ECG-gated myocardial perfusion single photon emission tomography (GSPET) in comparison with standard scintigraphic methods. Eight-frame gated SPET was recorded 60-90 min after the injection of 99Tcm-sestamibi at rest. The ejection fraction was calculated using a semi-automatic edge-detection technique based upon a threshold-searching method and compared with values obtained from first-pass (FPRNA) or equilibrium radionuclide angiography (ERNA) in 60 and 40 patients respectively with a broad range of ejection fraction values. Very good reproducibility was noted, with an inter- and intra-observer variability of -0.2 +/- 3.5% (range -7.6 to 6.9%, r = 0.97) and -0.2 +/- 2.2% (range -5.9 to 3.5%, r = 0.99) respectively. Similarly, a high concordance was found between GSPET and FPRNA and between GSPET and ERNA over the range of ejection fraction values (13 to 77%), the mean (+/-S.D.) difference being 0.8 +/- 3.8% (r = 0.97, P = N.S.) and 0.03 +/- 5.3% (r = 0.94, P = N.S.) respectively. Applying the Bland-Altman plot, no systematic bias of one method related to the other was observed, even at extreme ejection fraction values. Gated myocardial perfusion SPET with a 99Tcm tracer thus offers a unique opportunity to quantify cardiac performance and perfusion simultaneously and non-invasively.

Adult↗

Discriminative use of SPECT in frontal lobe-type dementia versus (senile) dementia of the Alzheimer's type.

UNLABELLED: Dementia of the Alzheimer's type [(S)DAT] and dementia with frontal features (FLD) are nosological entities with different prognoses and presumed pathophysiology. There is a need for noninvasive differential diagnostic tools. To evaluate whether SPECT perfusion imaging could discriminate between these neurodegenerative disorders, we performed a comparative study. METHODS: SPECT scans using 99mTc-hexamethylpropylene amine oxime (99mTc-HMPAO) of 21 patients with FLD were compared with those obtained in a group of 19 age- and severity-matched patients suffering from (S)DAT. Brain SPECT perfusion deficits were scored by visual qualitative analysis with respect to location, lateralization and severity. A total severity score of cerebral hypoperfusion (maximal value = 18) was calculated by adding all severity scores (scored between 0 and 3; 0 = no perfusion deficit; 1 = 13%-30% hypoperfusion; 2 = 30%-50%, hypoperfusion and 3 = > 50% hypoperfusion including breaching of the cortex) for right and left frontal, parietal and temporal lobes. Moreover, bifrontal hypoperfusion (Fa) was scored, yielding a value between 0 and 6 by adding the two frontal severity scores. RESULTS: No significant correlation was found between MMSE scores and total severity scores on SPECT. A statistically significant correlation was found between the Middelheim frontality score and frontal severity score. Statistically more significant bilateral hypoperfusion of the parietal lobes was found in the (S)DAT group. Conversely, bifrontal hypoperfusion was found more in the FLD group. Stepwise logistic regression analysis identified the severity of bifrontal hypoperfusion as the most significant contributing parameter to correctly classifying (S)DAT versus FLD on SPECT. The probability of predicting (S)DAT based on the SPECT scan is calculated with the following formula: [equation: see text] Using this equation, a value above 0.5 was predictive for (S)DAT and a calculated value under 0.5 was predictive for FLD. Using this model, 81% of the FLD group and 74% of the (S)DAT were correctly classified. CONCLUSION: Technetium-99m-HMPAO SPECT may help in discriminating FLD from (S)DAT. Bifrontal hypoperfusion was found to be the most powerful predictor of clinical classification. Further validation of the presented logistic regression model is warranted.

Aged↗

240 degrees: why not?

Single photon emission tomographic imaging of myocardial perfusion with 99Tcm-labelled agents is usually performed with single-detector gamma camera systems and 180 degrees anterior data collection. With multi-detector systems, reconstruction over 180 degrees and 360 degrees has been reported. We used a data set of normal subjects to compare both reconstruction methods. In addition, we tested an alternative approach, reconstructing data from 240 degrees acquisitions, excluding the right posterior views, which provide little myocardial information and which are responsible for a reduced signal-to-noise ratio. On the transverse slices, the known apical distortion with the 180 degrees reconstruction was not noted with the 360 degrees or 240 degrees reconstructions. Using semi-quantitative analysis of apical, mid-ventricular and basal short-axis slices, almost complete overlap was observed between the 240 degrees and 360 degrees circumferential profiles of our 20 normal volunteers, except in the inferior wall where a reduction in activity was noted. However, this finding was less pronounced with the 240 degrees than with the 180 degrees reconstruction. The frequent reduction in activity in the anterior wall was more prominent with the 180 degrees than with the 240 degrees and 360 degrees reconstructions. A 240 degrees acquisition represents a useful compromise between 180 degrees and 360 degrees imaging protocols when a single-detector device is used, allowing more homogeneous tracer distribution and a reduction in the apical distortion without material change of contrast or doubling of the acquisition time.

Adult↗

Technetium-99m HMPAO SPET in acute supratentorial ischaemic infarction, expressing deficits as millilitre of zero perfusion.

A comparative interim analysis was performed of clinical parameters, computed tomographic (CT) scan results and technetium-99m hexamethylpropylene amine oxime single-photon emission tomography (SPET) findings obtained within 12 h of acute supratentorial ischaemic infarction. First, the applicability for SPET semiquantification in this study of the "method of Mountz", simultaneously accounting for extent and degrees of hypoperfusion by expressing deficits as millilitre of zero perfusion, was considered. Next, the relative contributions of perfusion SPET and CT scan in the acute stage of ischaemic infarction were compared in 27 patients (mean age 68.8 years). Finally, the correlation of SPET lesions with clinical parameters at onset was evaluated. The method of Mountz represents a workable, accurate virtual parameter, with the assumption that the contralateral brain region remains uninvolved. Interobserver reproducibility in 12 SPET studies, with lesions varying between 6 and 369 cc, showed a correlation coefficient r of 0.99. In practice, because of inconstant distribution of activities in the brain, the method can only be applied slice by slice and not on the total global volume. While the mean delay since the onset of symptomatology was approximately 7 h for both SPET and CT scan, SPET showed lesions concordant with the clinical neurological findings in 100% and CT scan in only 48%. One could hypothesize that SPET examinations performed later would show larger functional defects, because of the development of additional functional changes secondary to biochemical alterations. However, in this regard no statistically significant differences were found between two subproups, taking the median of delay before SPET examination as cut-off.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Failure to label red blood cells adequately in daily practice using an in vivo method: methodological and clinical considerations.

This study was conducted to evaluate the frequency and possible causes of poor red blood cell (RBC) labelling when performing equilibrium gated blood pool (GBP) radionuclide angiography at rest with an in vivo method. The influence of the mode of administration on tagging efficiency was studied by investigating the image quality in 160 patients referred for evaluation of left ventricular (LV) function prior to or after coronary angiography, while using a roughly standardized administration protocol. The patients were subclassified into four groups according to the way both molecules involved in the tagging procedure were administered. When poor image quality was found (in 9.4% of the patients), the labelling efficiency was quantified and the frequency of failed tagging in each group was calculated. A significant association was found between poor labelling and the use of a Teflon catheter or butterfly needle for the injection of the stannous agent. In another 737 patients, in order to avoid the problems observed in the first group, a strict administration protocol was applied to analyse the frequency of poor tagging and its possible causes. Suboptimal image quality was present in 88 patients (11.9%). Quantitatively confirmed poor tagging was present in 36 of the 88 (40.9%, or 4.9% of the whole group); the remaining 52 patients showed borderline normal labelling (> 80% bound fraction). Drug interference was studied by comparing the medications used by the 36 patients showing poor binding with those used by 44 control patients. A significant relationship was found between the use of heparin or chemotherapy and the tagging. The influence of several clinical factors on the labelling was also investigated.(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors↗

Parameters influencing SPET regional brain uptake of technetium-99m hexamethylpropylene amine oxine measured by calibrated point sources as an external standard.

Using calibrated point sources as an external standard to convert single-photon emission tomography (SPET) brain counts into absolute values of regional brain uptake (rBU) of technetium-99m hexamethylpropylene amine oxime (HMPAO), the relative contribution of different parameters to interindividual variability of cerebellar rBU was examined in 33 healthy volunteers. Stepwise regression analysis identified body surface as the most important factor underlying interindividual variability (P < 0.001), when compared with brain volume. In the normal volunteer population presented, age decrement of rBU corrected for body surface and brain volume equalled 60.5-0.20 x age. Based on the data of eight normal volunteers, including four test-retest studies with heart rate (HR) differences greater than 5 units and four test-stress studies with doubling of heart rate after bicycle exercise, influence of heart rate may be expressed by the equation delta rBU = 0.35 delta HR. Clinically, estimation of the relative influence of different factors allows normalization and extension of the applicability of the rBU quantification method used from longitudinal studies to group comparisons. Interestingly, results of the Daily Stress Inventory Scale and a subjective rating scale suggest the absence of a significant influence of minor stress on rBU. When using one vial per patient, chromatography may be omitted in clinical routine practice and lipophilicity may be estimated as 90% of the injected dose, if administered within 10 min after preparation. Finally, sensitivity of the quantification method was tested in eight volunteers using acetazolamide brain activation and showed a mean increase in cerebellar rBU of 30.2%, varying between 14.1% and 75.9%.

Acetazolamide↗

Sensitivity and specificity of 99Tcm-HMPAO single-headed SPECT in dementia.

The sensitivity and specificity of 99Tcm-hexamethylpropyleneamine oxime (HMPAO) single-headed single photon emission computed tomography (SPECT) in dementia were evaluated in elderly patients with a mean age of 84 years suffering from dementia (n = 59) and compared to an age- and sex-matched control group with normal cognitive function (n = 14). The demented patients were classified as suffering from primary degenerative dementia (PDD, n = 51) based on DSM-III-R criteria. Moreover, PDD patients were divided into three subgroups of severity of cognitive impairment, according to their Folstein score. Multi-infarct dementia (MID, n = 8) was diagnosed based on clinical features, computed tomographic findings and Hachinski ischaemic score. Images were assessed qualitatively by visual interpretation of shades of colour in cortical regions. A SPECT defect confined to the frontal, parietal, temporal or (parieto) occipital lobe was defined as one lesion. The mean number of SPECT lesions was 1.4 (range 0-4) in the control group, 2.4 (range 0-8) in the PDD group and 2.9 (range 2-5) in the MID group and showed a significant difference (P < 0.02) between groups. To obtain an acceptable level of specificity of 64.3%, a cut-off value of three lesions had to be chosen. In the PDD group, sensitivity was then 25% for the mildly, 43.8% for the moderately and 46.7% for the severely affected PDD subgroup. In the MID group sensitivity was then 75%. Interestingly, in this elderly patient population the location of lesions was homogenously distributed in all groups, including the control group.

Aged↗

Involvement of the renal parenchyma in acute urinary tract infection: the contribution of 99mTc dimercaptosuccinic acid scan.

We performed 99mTc dimercaptosuccinic acid (DMSA) scan and ultrasonography in 146 children during the acute phase of a proven urinary tract infection (UTI). In 99 a micturating cysto-urethrography and in 83 an intravenous urography was also done. The occurrence of fever and increased WBC count, CRP and ESR were also studied. It appeared from this retrospective study that 47% of the kidneys had a cortical or patchy pattern of decreased uptake of 99mTc DMSA, as compared to 23% with abnormal findings on US. Vesico-ureteral reflux was present in 38% of the kidneys with parenchymal involvement on 99mTc DMSA scan. Although fever, leucocytosis and elevated CRP and ESR were significantly correlated with abnormal 99mTc DMSA scan, they were also observed in children without renal parenchymal involvement. Our results suggest that 99mTc DMSA scan is a sensitive method for the detection of parenchymal involvement during acute UTI. The exact nature of these lesions and their relation with scars need, however, to be defined.

Acute Disease↗

Improvement in the efficacy of exercise first-pass radionuclide angiocardiography in detecting coronary artery disease and the effect of patient age.

The most widely used criterion of normality during exercise radionuclide angiocardiography (a five EF units increase in left ventricular ejection fraction from rest to exercise) has been established in young, healthy volunteers resulting in a relatively low specificity when applied to older, less fit patients or in women. In a group of 57 patients ranging in age from 22 to 79 years with a low likelihood of coronary artery disease, the age of the patient was the only independent variable predicting left ventricular ejection fraction change during exercise. The efficacy of a new age-based criterion for the diagnosis of coronary artery disease was then evaluated in 115 patients with chest pain undergoing both exercise first-pass radionuclide angiocardiography and coronary arteriography. Compared to the classic five EF unit criterion, the age-based criterion had a higher specificity (73.2% vs 34.1% P less than 0.001) without significant loss in sensitivity (85.1% vs 92.6%; P = NS).

Adult↗

Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction.

BACKGROUND: The diagnostic value and incremental contribution of different noninvasive tests to the identification of coronary artery disease in 128 patients from a general population with intermediate pretest likelihood (48.0%) were determined by ordered logistic regression analysis and receiver-operating characteristic (ROC) curves. METHODS AND RESULTS: Patients referred for suspicion of coronary heart disease were submitted to bicycle exercise testing under clinical and electrocardiographic control. AT peak exercise, first-pass radionuclide angiography was performed after injection of 99mTc-labeled sestamibi, followed by single-photon emission computed tomographic (SPECT) acquisition. A comparative rest study was obtained within 1 week, and qualitative and quantitative analysis was applied to assess the presence and extent of disease. With coronary angiography and 50% stenosis used as a standard, the discriminative accuracy of each test was calculated. The accuracies to diagnose coronary heart disease were 71.3% +/- 4.7% for the bicycle test, 66.7% +/- 5.3% for radionuclide angiography, and 81.6% +/- 3.9% for the SPECT data. By ROC curves, the optimal criteria for positivity were determined for the visual and quantitative analysis for both presence and extent of coronary artery disease. Results of visual and quantitative SPECT were compared in terms of area under the ROC curves. The diagnostic performances showed no significant difference, ranging from 74.3% to 81.6%. The first-pass radionuclide angiographic and SPECT data were added progressively to the stress testing to evaluate their incremental diagnostic contribution. Only the addition of SPECT results significantly increased the accuracy to 85.6% +/- 3.3% (p < 0.0001). CONCLUSION: Exercise electrocardiography and first-pass radionuclide angiography showed comparable accuracy to detect coronary artery disease. However, the combination of exercise testing and visual SPECT analytic data sufficed to ensure diagnostic accuracy, without significant benefit from the addition of other tests or the application of quantification.