Three-dimensional effects in retraction appliance design.

The clinical importance of the three-dimensional effects of the force systems supplied by appliance designs used for retraction has long been appreciated. However, quantification of these force systems is not as well known. In this work, a numerical method is used to provide quantitative insight into three-dimensional effects for typical appliance designs. One problem that occurs clinically is the axial rotation of a single rooted tooth as a result of the forces being applied by the retraction device on the tooth's buccal surface. An out-of-plane preactivated bend can be used to counteract this rotation. The proposed numerical method can accurately determine the force systems resulting from this out-of-plane preactivation as well as the in-plane force systems. It is shown that the out-of-plane effects are independent of the in-plane behaviour so that the usual forces and moment to force ratios are maintained.

Elasticity↗

Large deformation analysis of orthodontic appliances.

The deformations of orthodontic appliances used for space closure are large so that any mathematical analysis will require a nonlinear approach. Existing incremental finite element and finite difference numerical methods suffer from excessive computational effort when analyzing these problems. An accurate segmental technique is proposed to handle these difficulties in an extremely efficient fashion. The segmental technique starts by assuming that an orthodontic appliance is composed of a number of smaller segments, the ends of which undergo small relative rotation. With an appropriate choice of local coordinate system the equilibrium equations for each segment are linearized and solved in a straightforward manner. The segments are then assembled using geometric and force compatibility relations similar to the transfer matrix method. Consequently, the original nonlinear boundary value problem is solved as a sequence of linear initial value problems which converge to the required boundary conditions. As only one segment need be considered at a time, the computations can be performed accurately and efficiently on a PC type computer. Although an iterative solution is used to match the boundary conditions, the time required to solve a given problem ranges from a few seconds to a couple of minutes depending on the initial geometric complexity. The accuracy of the segmental technique is verified by comparison with an exact solution for an initially curved cantilever beam with an end load. In addition, comparisons are made with existing experimental and numerical results as well as with a new set of experimental data. In all cases the segmental technique is in excellent agreement with the results of these other studies.

Equipment Design↗

The use and abuse of the Periotest for 2-piece implant/abutment systems.

While the Periotest continues to be used in assessing the integrity of implants, there are numerous reports of its inconsistencies. To understand more precisely what the Periotest is actually measuring, a mathematical model was developed that illustrates the effect that various geometric and clinical parameters have on the Periotest value (PTV). In addition, the model was validated with an in vitro experiment. Results of the mathematical model are shown to correlate with those obtained from the experimental test The PTV is very sensitive to the position at which the Periotest impacts the abutment and to angulation of the handpiece. It was shown that a change in position of 1 mm in striking height can produce a difference in PTV of between 1 and 2. Since the angulation of the handpiece can produce a difference in striking position of 2 mm, it must be controlled as well. The model also showed that the Periotest can detect changes in bone height of 0.5 mm.

Acceleration↗