PubMed Health⌕ Search

Biomedical subjects

A W Schoenenberger

Publications and source records attributed to A W Schoenenberger.

13 recordsLinked to original sources

[Nasal polyps and osteolyses].

A 38-year-old man presented with a 2-month history of progressive leg pain. An x-ray film of both tibial bones showed multiple osteolysis. At the same time, nasal polyps were present. A biopsy of the tibial bone remained unclear. A carcinoma was not found. A biopsy of the nasal polyps revealed a Rosai-Dorfman-Destombes disease.

Adult↗

MR guidance of laser disc decompression: preliminary in vivo experience.

The purpose of this study was to perform percutaneous laser disc decompression (PLDD) under MR guidance in an open configuration 0. 5-T MR system. Following failed conservative treatment for 6 months, eight patients with contained disc herniations were enrolled in the study. Following MR guided introduction of the laser fiber into the targeted disc space, the laser-induced temperature distribution was visualized using a color-coded subtraction technique based on a T1-weighted GRE sequence. In seven patients PLDD could be performed. In all cases laser effects were depicted by MR. In this regard the color-coded technique was found to be superior to conventional magnitude images. Whereas no apparent decrease in the extent of herniation was discovered immediately following PLDD, T2-weighted FSE images showed signal intensity alterations in two of the seven patients. Clinical evaluation, obtained 3-4 months after PLDD, revealed a fair (n = 2) or good (n = 4) response to the treatment. One patient showed no change in symptoms. MR guidance and monitoring of PLDD is feasible within an open 0.5-T system and seems to render PLDD more safe and controllable.

Adult↗

Contrast-enhanced three-dimensional magnetic resonance angiography of the splanchnic vasculature before and after caloric stimulation. Original investigation.

RATIONALE AND OBJECTIVES: To develop a comprehensive noninvasive magnetic resonance angiography (MRA) strategy for the morphologic and functional assessment of the splanchnic arteries, based on a combination of breath-held contrast-enhanced 3D MRA and segmented k-space 2D phase-contrast acquisitions acquired before and after caloric stimulation. METHODS: Ten healthy volunteers were examined twice: once in the fasting state (6 hours with no food intake) and a second time following caloric stimulation with a standard 475-kcal meal. Flow in the superior mesenteric artery (SMA) and vein (SMV) was quantitated using a 2D breath-held, segmented k-space phase-contrast (PC) acquisition in a plane perpendicular to the axis of the vessels, while vascular morphology was displayed with a contrast-enhanced 3D MRA acquisition consisting of 44 contiguous 2-mm sections, acquired in apnea (28 seconds). For comparative analysis, the splanchnic vasculature was divided into 11 segments and evaluated on a 2-point scale (cannot exclude pathology, can exclude pathology). RESULTS: Flow volume in the SMA increased from 2.3 ml/min/kg (+/- 0.9 ml/min kg) to 7.3 ml/min kg (+/- 4.7 ml/min kg) following caloric stimulation (P < 0.05). Flow in the SMV exceeded flow in the SMA and increased from 3.4 ml/min/kg (+/- 0.3 ml/min kg) to 9.1 ml/min/kg (+/- 4.8 ml/min/kg) following stimulation. Flow volume of SMV correlated better with SMA flow after stimulation. Caloric stimulation significantly improved visualization of the splanchnic arterial vasculature (P < 0.05). Only 5 of 110 evaluated arterial segments (4.5%) remained inadequately seen to exclude vascular pathology. CONCLUSION: Magnetic resonance imaging offers a comprehensive assessment of the splanchnic arterial vasculature based on 3D display of vessel morphology and analysis of flow function. While the most relevant proximal vessel segments are visible even under fasting conditions, caloric stimulation enhances visualization of small vessels.

Adult↗

Dynamic MR defecography with a superconducting, open-configuration MR system.

PURPOSE: To evaluate dynamic magnetic resonance (MR) defecography performed with a superconducting, open-configuration system in diagnosis of defecation disorders. MATERIALS AND METHODS: Five healthy volunteers and 15 patients with defecation disorders were studied with MR defecography performed with a superconducting, open-configuration system; the patients also underwent fluoroscopic defecography. Before MR imaging, the rectum was filled with 300 mL of mashed potatoes mixed with 1.5 mL of gadopentetate dimeglumine. T1-weighted gradient-echo images were acquired every 2 seconds in the midsagittal plane with the patient at rest, at maximal contraction of the anal sphincter, during straining, and during defecation. RESULTS: MR defecography permitted analysis of the anorectal angle, anal canal, puborectal muscle, and descent of the pelvic floor. Owing to the high signal intensity of the intraluminal contrast material, the rectal walls were well demonstrated on the MR images, permitting visualization of intussusception and rectocele. Concomitant demonstration of structures surrounding the anorectal canal was helpful in assessment of spastic pelvic floor syndrome and descending perineum syndrome. MR defecography was superior to fluoroscopic defecography and allowed detection of all clinically relevant pathologic conditions except for one. CONCLUSION: Dynamic MR defecography is an attractive alternative for evaluation of defecation disorders.

Aged↗

Imaging temperature changes in an interventional 0.5 T magnet: in-vitro results.

BACKGROUND AND OBJECTIVE: To evaluate the ability of monitoring laser induced temperature changes in an open, interventional 0.5 T magnet, adopting fast T1-weighted sequences. MATERIALS AND METHODS: A fast gradient echo- (FGRE) and a fast spoiled gradient echo-sequence (FSPGR), both enabling an image update every 2.5 s, were investigated for their ability to visualize laser tissue effects at 5 Watt. Laser induced temperature was fluorooptically measured and correlated with signal intensity (SI) changes depicted by magnetic resonance imaging (MRI). MRI-lesions were compared with macroscopic findings. RESULTS: SI changes on FGRE images appeared as early as 15 s following the onset of laser application and were significantly more pronounced than those seen on FSPGR images (p < .0001). A correlation of r = 0.94 (FGRE) and r = 0.92 (FSPGR) between temperature and SI loss was established. Owing to a steeper slope, the FGRE sequence was considered more sensitive to temperature changes. The areas of macroscopic tissue change correlated with those of SI loss, but lesion size was generally underestimated by MRI. CONCLUSION: Laser monitoring is possible with rapid image updates in a midfield (0.5 T) interventional MRI environment using fast gradient echo sequence designs.

Animals↗

Virtual colonoscopy with magnetic resonance imaging: in vitro evaluation of a new concept.

BACKGROUND & AIMS: Screening for colonic polyps is desirable. A new concept based on cross-sectional and endoscopic analysis of a magnetic resonance (MR) data set is presented. METHODS: Ex vivo autopsy colonic specimens, containing artificially placed polyps, were obtained and filled with a gadolinium-containing solution. Forty-four thin-section MR images were obtained in a 1.5-T MR scanner in 28 seconds. A three-dimensional endoscopic fly-through of these images was rendered. Fly-throughs and two-dimensional cross-sectional images were analyzed by two observers for the presence of polyps. RESULTS: The average sensitivity and specificity for the detection of polyps based on three-dimensional endoscopic MR colon imaging were 87% and 96%, respectively. Analysis of cross-sectional images showed an overall sensitivity and specificity of merely 57% and 84%, respectively. The difference in the interpretation of three-dimensional MR colonoscopy and two-dimensional cross-sections was statistically significant (P < 0.001). With three-dimensional MR colonoscopy, overall sensitivity for detection of polyps measuring < or =5 mm in length and diameter was 70%; for larger polyps, it increased to 95% (P < 0.01). CONCLUSIONS: The feasibility of an MR-based endoluminal assessment of the colon is shown. Minimal invasiveness, lack of radiation exposure, and high in vitro diagnostic accuracy warrant further investigation of this novel concept.

Colonic Polyps↗

Real-time monitoring of laser diskectomies with a superconducting, open-configuration MR system.

OBJECTIVE: The objective of our study was to assess the ability of a 0.5-T superconducting, open-configuration MR system to guide laser diskectomies. The study was performed ex vivo on six human cadavers as well as in vivo on three patients. CONCLUSION: The macroscopic size of necrosis correlated well with the monitored temperature spread (r2 = .76-.85). After MR-guided introduction of the laser fiber into the targeted disk space, temperature spread was visualized in all subjects.

Adolescent↗

[Check-up at 40 years of age].

A chest radiograph performed on a 40-year-old patient revealed a smoothly contoured right posterosuperior opacity. CT scans demonstrated a sharply defined homogeneous mass without enhancement. In a transbronchial FNA specimen, ciliated cells were found. Transesophageal ultrasound showed a hypoechoic structure, distinct from the esophagus. The patient underwent surgical excision. The postoperative finding confirmed the diagnosis of a bronchogenic cyst.

Adult↗

[Puncture with an open-sided, interventional MRI system. Illustration with a case report].

INTRODUCTION AND METHODS: A 0.5 T open-configuration MR system allows free access to the patient via a 58-cm-wide opening on both sides of the machine. A newly developed system for needle guidance enables the examiner to perform biopsies in combination with real-time imaging and to position laser fibers in the human body. For imaging, a 2D gradient echo sequence is used (TR 19 ms, TE 9 ms, flip angle 30 degrees FOV 24 x 24 cm, slice thickness 10 mm matrix 256 x 128). The acquired images are displayed on two LCD screens localized within the MR system, thus allowing an interactive needle guidance. This procedure is illustrated by a case report. DISCUSSION: The handling of the system for needle guidance was simple, mainly due to a real-time adaption of the scan plane to the needle direction. The possibility of multi-angulated approaches makes biopsies of hardly accessible anatomic regions feasible. CONCLUSION: We think that MR-guided needle positioning will play an important role in combination with thermosensitive therapies. Thermosensitivity of MR imaging allows extensive monitoring of such interventions.

Adult↗

[Influence of respiration and pulsatility on the accuracy of MR-phase contrast flow measurements: "in vitro" evaluation].

PURPOSE: Determination of the influence of pulsatility of blood flow and respiration-induced vascular motion on the accuracy of MR phase contrast flow measurements. MATERIAL AND METHODS: Flow measurements in phantoms were performed with the phase contrast technique in a 1.5 Tesla MRI system using different flow volumes, varying degrees of flow pulsatility and a varying number of image phases. To determine the influence of respiratory motion on flow measurement accuracy, flow data was collected during motion of the whole phantom. RESULTS: Flow measurements based on 6 and 16 image phases were significantly more accurate (p < 0.05) than those based on one phase. An increase in the degree of pulsatility resulted in a widening of the error range. Hence, increasing pulsatility demands an increase in the number of acquired phases to maintain sufficient measurement accuracy. Simulated respiratory motion with an excursion depth of only 5 mm resulted in a significant overestimation of true flow ranging between 22.9 and 42.1%. Measurements without simulated respiratory motion were more accurate (p < 0.001). An excursion depth of 15 mm led to a vast increase in the apparent vessel size in excess of 100%. Flow volume measurements increased accordingly to 1126 ml/min (true flow = 720 ml/min). CONCLUSION: Accurate phase-contrast based flow measurements require an adjustment of acquisition parameters to correspond to the physiology of the vessel under consideration. Flow data in vessels subject to respiratory motion should only be collected in apnoea.

Blood Flow Velocity↗

[Interactive stereotaxic interventions in superconducting, open 0.5-Tesla MRI tomography].

PURPOSE: Evaluation of an interactive, stereotactic biopsy device integrated in an open superconductive 0.5 tesla MR-scanner with a vertical gap. MATERIAL AND METHODS: In addition to "in-vitro" experiments performed on a plexiglas phantom with holes of varying diameters (5-20 mm) biopsies on eleven patients (7 women, 4 men; average age 55 years) were performed in the interventional MR-system. Lesions in the abdomen (n = 6), muscle (n = 1), thyroid (n = 3) and breast (n = 1) were targeted with 18-20 G aspiration biopsy needles of 5-15 cm length. The intervention was interactively guided by a fast T1-weighted 2-D gradient echo sequence. RESULTS: All of the 15 and 20 mm holes of the phantom, but only 83% of the 10 and 5 mm holes were hit. No complications occurred during the MR-guided patient procedures. All lesions (mean size 3.5 cm, distance from the skin 2 cm to 10 cm) were biopsied successfully. The fast image acquisition in combination with the stereotactic technique enables interactive control of the needle. CONCLUSIONS: Stereotactic, interactively controlled biopsies in the interventional MR are technical feasible. However, the range of meaningful indications for MR-guided biopsies is limited.

Abdominal Neoplasms↗

MR defecography: depiction of anorectal anatomy and pathology.

With the advent of open-configuration MR systems, enabling image acquisition in a vertical patient position, MR defecography has become possible. MR defecography permits analyses of the anorectal angle, opening of the anal canal, functioning of the puborectal muscle, and descent of the pelvic floor during defecation. The rectal walls are well delineated on the GRE images, permitting visualization of intussusceptions and rectoceles. The concomitant depiction of structures surrounding the anorectal canal is helpful in the assessment of a spastic pelvic floor and the descending perineum syndrome and in permitting visualization of enteroceles. Dynamic MR defecography is an attractive alternative in the evaluation of defecation disorders.

Adult↗