Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear accelerators offer several physical advantages over lower energy ones: the skin dose is lower, the beam is more penetrating, and the scattered dose to tissues outside the target volume is smaller. Nevertheless, the contamination of undesirable neutrons in the therapeutic beam, generated by the high-energy photons, has become an additional problem as long as patient protection and occupational doses are concerned. The treatment room walls are shielded to attenuate the primary and secondary X-ray fluence, and this shielding is generally adequate to attenuate the neutrons. However, these neutrons are scattered through the treatment room maze and may result in a radiological problem at the door entrance, a high occupancy area in a radiotherapy facility. In this article, we used MCNP Monte Carlo simulation to calculate neutron doses in the maze of radiotherapy rooms and we suggest an alternative method to the Kersey semi-empirical model of neutron dose calculation at the entrance of mazes. It was found that this new method fits better measured values found in literature, as well as our Monte Carlo simulated ones.

Body Burden↗

Neutron scattering in concrete and wood.

In this work, the energy spectra of photoneutrons, scattered by ordinary, high-density concrete and wood barriers, have been evaluated using the MCNP4B code. These spectra were calculated for different scattering angles, and for incident neutron energies varying between 0.1 and 10 MeV. The results presented are required to simulate typical photoneutron fluence, produced by medical accelerators, which is scattered by the room walls and reaches the door. It was found that the mean energy of the scattered neutrons does not depend on the scattering angle. Furthermore, it was found that the scattered neutron energies are lower in wood and baryte concrete, which indicates that these materials can be used for lining the maze walls in order to reduce neutron dose at the room door. These data will help to estimate the personal dose received by the patient and staff in radiotherapy facilities.

Air Pollution, Indoor↗

A study of neutron spectra from medical linear accelerators.

Medical accelerators with photon energies over 10 MeV generate an undesired fast neutron contamination in the therapeutic beam. In this work, the Monte Carlo code MCNP was used to simulate the transport of these photoneutrons across the head of various medical accelerators of high energy. The average and most probable neutron energies were obtained from these spectra, before and after crossing the accelerator shielding. The degradation of these spectra, when they cross concrete barriers with thickness which vary between 25 and 100 cm, was also studied.

Artifacts↗

Monte Carlo simulation of response function for a NaI(Tl) detector for gamma rays from 241Am/Be source.

The general purpose computer code MCNP4B was used to simulate the response function of a bare NaI(Tl) detector crystal for gamma rays from an 241Am/Be source capsule. The simulated spectral shape generated by the MCNP4B code was compared with the measured spectral shape obtained using a gamma-ray spectrometer with a cylindrical shape, 7.62 cm x 7.62 cm, NaI(Tl). In general, the agreement between the simulation and the experimental response function was good.

Journal Article↗

Calculation of conversion coefficients for clinical photon spectra using the MCNP code.

In this work, the MCNP4B code has been employed to calculate conversion coefficients from air kerma to the ambient dose equivalent, H*(10)/Ka, for monoenergetic photon energies from 10 keV to 50 MeV, assuming the kerma approximation. Also estimated are the H*(10)/Ka for photon beams produced by linear accelerators, such as Clinac-4 and Clinac-2500, after transmission through primary barriers of radiotherapy treatment rooms. The results for the conversion coefficients for monoenergetic photon energies, with statistical uncertainty <2%, are compared with those in ICRP publication 74 and good agreements were obtained. The conversion coefficients calculated for real clinic spectra transmitted through walls of concrete of 1, 1.5 and 2 m thick, are in the range of 1.06-1.12 Sv Gy(-1).

Computer Simulation↗