PubMed Health⌕ Search

Biomedical subjects

A Y Cho

Publications and source records attributed to A Y Cho.

9 recordsLinked to original sources

Near-perfect correlation of the resistance components of mesoscopic samples at the quantum Hall regime.

We study the four-terminal resistance fluctuations of mesoscopic samples near the transition between the nu=2 and the nu=1 quantum Hall states. We observe near-perfect correlations between the fluctuations of the longitudinal and Hall components of the resistance. These correlated fluctuations appear in a magnetic-field range for which the two-terminal resistance of the samples is quantized. We discuss these findings in light of edge-state transport models of the quantum Hall effect. We also show that our results lead to an ambiguity in the determination of the width of quantum Hall transitions.

Journal Article↗

Internally excited acoustic resonator for photoacoustic trace detection.

The quantum-cascade laser can be used as an infrared source for a small portable photoacoustic trace gas detector. The device that we describe uses a quantum-cascade laser without collimating optics mounted inside an acoustic resonator. The laser is positioned in the center of a longitudinal resonator at a pressure antinode and emits radiation along the length of the resonator exciting an axially symmetric longitudinal acoustic mode of an open-ended cylindrical resonator. Experiments are reported with an 8-microm, quasi-cw-modulated, room-temperature laser used to detect N2O.

Journal Article↗

Observation of a quantized hall resistivity in the presence of mesoscopic fluctuations.

We present an experimental study of mesoscopic, two-dimensional electronic systems at high magnetic fields. Our samples, prepared from a low-mobility InGaAs/InAlAs wafer, exhibit reproducible, sample specific, resistance fluctuations. Focusing on the lowest Landau level, we find that, while the diagonal resistivity displays strong fluctuations, the Hall resistivity is free of fluctuations and remains quantized at its nu=1 value, h/e(2). This is true also in the insulating phase that terminates the quantum Hall series. These results extend the validity of the semicircle law of conductivity in the quantum Hall effect to the mesoscopic regime.

Journal Article↗

Detection of biogenic CO production above vascular cell cultures using a near-room-temperature QC-DFB laser.

We report the first application of pulsed, near-room-temperature quantum cascade laser technology to the continuous detection of biogenic CO production rates above viable cultures of vascular smooth muscle cells. A computer-controlled sequence of measurements over a 9-h period was obtained, resulting in a minimum detectable CO production of 20 ppb in a 1-m optical path above a standard cell-culture flask. Data-processing procedures for real-time monitoring of both biogenic and ambient atmospheric CO concentrations are described.

Air Conditioning↗

Spectroscopic detection of biological NO with a quantum cascade laser.

Two configurations of a continuous wave quantum cascade distributed feedback laser-based gas sensor for the detection of NO at a parts per billion (ppb) concentration level, typical of biomedical applications, have been investigated. The laser was operated at liquid nitrogen temperature near lambda = 5.2 microns. In the first configuration, a 100 m optical path length multi-pass cell was employed to enhance the NO absorption. In the second configuration, a technique based on cavity-enhanced spectroscopy (CES) was utilized, with an effective path length of 670 m. Both sensors enabled simultaneous analysis of NO and CO2 concentrations in exhaled air. The minimum detectable NO concentration was found to be 3 ppb with a multi-pass cell and 16 ppb when using CES. The two techniques are compared, and potential future developments are discussed.

Breath Tests↗

Absorption spectroscopy with quantum cascade lasers.

Novel pulsed and cw quantum cascade distributed feedback (QC-DFB) lasers operating near lambda=8 micrometers were used for detection and quantification of trace gases in ambient air by means of sensitive absorption spectroscopy. N2O, 12CH4, 13CH4, and different isotopic species of H2O were detected. Also, a highly selective detection of ethanol vapor in air with a sensitivity of 125 parts per billion by volume (ppb) was demonstrated.

Air Pollution, Indoor↗

Self-mode-locking of quantum cascade lasers with giant ultrafast optical nonlinearities.

We report on the generation of picosecond self-mode-locked pulses from midinfrared quantum cascade lasers, at wavelengths within the important molecular fingerprint region. These devices are based on intersubband electron transitions in semiconductor nanostructures, which are characterized by some of the largest optical nonlinearities observed in nature and by picosecond relaxation lifetimes. Our results are interpreted with a model in which one of these nonlinearities, the intensity-dependent refractive index of the lasing transition, creates a nonlinear waveguide where the optical losses decrease with increasing intensity. This favors the generation of ultrashort pulses, because of their larger instantaneous intensity relative to continuous-wave emission.

Journal Article↗

Effective utilization of quantum-cascade distributed-feedback lasers in absorption spectroscopy.

A variable duty cycle quasi-cw frequency scanning technique was applied to reduce thermal effects resulting from the high heat dissipation of type I quantum-cascade lasers. This technique was combined with a 100-m path-length multipass cell and a zero-air background-subtraction technique to enhance detection sensitivity to a parts-in-10(9) (ppb) concentration level for spectroscopic trace-gas detection of CH4, N2O, H2O, and C2H5OH in ambient air at 7.9 micrometers. A new technique for analysis of dense high resolution absorption spectra was applied to detection of ethanol in ambient air, yielding a 125-ppb detection limit.

Air Pollution, Indoor↗

Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser.

A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

Atmosphere↗