PubMed HealthSearch

Biomedical subjects

A al-Kutoubi

Publications and source records attributed to A al-Kutoubi.

At least 19 recordsLinked to original sources

Omental cake--cause?

Explore the source record for details and available documents.

Diagnosis, Differential

Retrieval of detached coating of a hydrophilic guidewire from the profunda femoris artery using an Amplatz gooseneck snare.

We present a case where during accidental puncture of the profunda femoris artery the plastic coating of a hydrophilic guidewire was stripped off against the bevel of a metal needle. This lay coiled in the profunda femoris artery. It was retrieved using an Amplatz gooseneck snare from an ipsilateral antegrade common femoral artery puncture.

Catheterization, Peripheral

Duplex scanning in the postoperative surveillance of patients undergoing total hip arthroplasty.

Color flow duplex imaging is a well-established method for the diagnosis of deep vein thrombosis in symptomatic patients; however, the sensitivity and specificity of duplex scanning compared with venography in high-risk asymptomatic patients are not known. Consecutive patients undergoing total hip arthroplasty who consented to have bilateral venography on days 8 to 12 were included in this prospective study. One hundred and fifty-one venograms were finally obtained in 78 patients. All duplex scanning was performed with the Ultramark 9 ATL (Advanced Technology Laboratories) by one investigator. In the beginning of the study, the first 44 legs, only the femoropopliteal segment was tested and the result was based on B-mode compression; the sensitivity for the duplex was 56% (5/9), and the specificity, 94% (33/35). In the next 107 legs, the addition of color to our criteria improved the sensitivity of the duplex scan from 55% to 93% (13/14) for the femoropopliteal segment and the specificity from 94% to 99% (92/93). For the calf segment, in the same 107 legs, using the color facility of the duplex, the sensitivity and specificity were 79% (15/19) and 97% (85/88), respectively. The color facility of new-generation machines makes duplex scanning reliable for the detection of proximal deep vein thrombosis, even in asymptomatic high-risk patients. For the detection of calf deep vein thrombosis, however, more experience is needed. A larger study is necessary to confirm these preliminary data.

Aged

Pulmonary artery occlusion by tuberculous mediastinal lymphadenopathy.

Two cases of tuberculous mediastinal lymphadenopathy are presented in which the clinical features mimicked those of pulmonary embolism, causing striking abnormalities on radionuclide scintigraphy. It is concluded that tuberculous mediastinal lymphadenopathy should be included in the differential diagnosis of reduced lung perfusion due to proximal pulmonary artery occlusion.

Adult

Pulmonary artery reconstruction for tuberculosis.

A 35-year-old woman underwent reconstruction of her right pulmonary artery for treatment of acquired right pulmonary artery stenosis. The stenosis was secondary to tuberculosis causing both an extrinsic and an intrinsic obstructive component. After her reconstruction, the patient made an uneventful recovery, and perfusion to the right lung was subsequently restored.

Adult

The role of common carotid artery end-diastolic velocity in near total or total internal carotid artery occlusion.

OBJECTIVES: To evaluate the role of the end-diastolic velocity (EDV) in the common carotid artery (CCA) as a marker of internal carotid artery (ICA) occlusion. DESIGN: Validation of retrospective data in a prospective clinical study. METHODS: The EDV in 94 patients with total ICA occlusion and in 24 patients with high grade (95-99%) unilateral ICA stenosis identified on extracranial carotid colour-flow Duplex imaging (CFDI) and arteriography was reviewed, and was retrospectively compared to the EDV of 176 normal individuals. Identification of patients with ICA occlusion was most accurate (99.3%) with an ipsilateral EDV > or = 12 cm/s and a DIFF > or = 10 cm/s (DIFF = contralateral EDV -- ipsilateral EDV). These values were then prospectively applied to all 886 patients (67 with high grade stenosis or occlusion) who underwent CFDI at our institution during 1994. RESULTS: The EDV > or = 12 had a 92% sensitivity, a 99.4% negative predictive value (NPV) and a 85% specificity in distinguishing between occluded and patent ICA's. In combination with a DIFF > or = 10 was 80.4% sensitive and 97.5% specific. The positive predictive value of the EDV > or = 12 in the distinction between 95-99% ICA stenosis and ICA occlusion was 78.3%, and that of the combination was 85.4%. The EDV was rarely zero and 10% of patients with normal or minimally diseased ICA's had an EDV > or = 12 and/or a DIFF > or = 10. CONCLUSIONS: The EDV < or = 12 cm/s is a sensitive marker of ICA occlusion with a high NPV and in combination with the DIFF > or = 10 cm/s, is specific. Nevertheless, EDV parameters are inaccurate in the distinction of 95-99% ICA stenosis from occlusion. Low EDV can be found in a number of patients with minor or no ICA disease, particularly in those with a stroke or silent cerebral infarct.

Adult

Imaging the spine.

This article on neuroradiology concerns the imaging of the spine. The imaging modalities are discussed, and some basic imaging strategies are outlined.

Bone Neoplasms

Draped aorta: CT sign of contained leak of aortic aneurysms.

PURPOSE: To evaluate the usefulness of a new computed tomographic (CT) sign of "draped aorta" in the diagnosis of a contained leak in an aortic aneurysm. MATERIALS AND METHODS: CT scans were retrospectively evaluated in 10 patients in whom an unidentifiable aortic wall and posterior aspect of the aorta that followed the vertebral contour were seen. CT findings were compared with those at surgery. RESULTS: Seven patients had a deficient aortic wall and a contained leak. Two patients had a deficient wall and a mycotic aneurysm. One patient had a false aneurysm at the aortic graft anastomosis. CONCLUSION: On CT images, draping of the aorta if highly indicative of deficiency of the aortic wall and a contained leak.

Aortic Aneurysm, Abdominal

Deep venous thrombosis prophylaxis with low molecular weight heparin and elastic compression in patients having total hip replacement. A randomised controlled trial.

Seventy-eight patients having elective total hip replacement were randomised into 3 groups A) control; B) low molecular weight heparin: (enoxaparin 40 mg once daily) and C) enoxaparin (40 mg once daily) plus graduated elastic compression (TEDR stockings) for 8-12 days. All patients had a preoperative perfusion lung scan and chest X-Ray and a postoperative perfusion/ventilation scan together with bilateral ascending venography on days 8-12. A blood sample was taken preoperatively, on the 1st, 3rd and 5th postoperative day and at the end of the study. The control group received placebo injections. The venograms and V/Q scans were reported blindly by an independent panel of three and one radiologists respectively. An independent panel of assessors stopped entry in the control group when a total of 45 patients were admitted according to Ethics Committee directives. The study continued with groups B and C. The incidence of DVT (including isolated asymptomatic calf thrombi) was as follows: Group A (n = 14) 93%; Group B (n = 32) 38%; Group C (n = 32) 25% (chi 2; p < 0.001 for group A versus B or C). The incidence of proximal DVT was: Group A 57%; group B 28%; group C 13% (chi 2; p = 0.057 for group A versus B and p < 0.005 for group A versus C). The incidence of silent pulmonary embolism (PE) (new defect on V/Q scan) was 28% (8 out of 29) in patients with and 5% (2 out of 43) in patients without DVT (chi 2; p < 0.02). The combination of high TAT and low anti-Xa activity on the 1st postoperative day identified a high risk group of patients who had a 56% incidence of proximal DVT on the 8th to 12th postoperative day. Further studies are needed to confirm the suggested increased efficacy in prophylaxis by the combination of LMWH and GEC as compared with LMWH alone.

Aged

V/Q defects and deep venous thrombosis following total hip replacement.

Seventy-two patients undergoing elective total hip replacement were studied with bilateral venography, pre-operative and post-operative lung scans. Twelve belonged to a control group that received placebo injections and 60 patients to treatment groups that received low molecular weight heparin. The incidence of deep venous thrombosis was 11 (92%) of 12 patients in the control group and 18 (30%) of 60 patients in the treatment group (X2: P < 0.001). The incidence of pulmonary embolism (new unmatched perfusion defects) was five (42%) of the 12 patients in the control group and five (8.3%) of the 60 patients in the treatment groups (X2: P < 0.002). The incidence of pulmonary embolism (new unmatched perfusion defects) was eight (27.5%) of 29 patients with deep venous thrombosis and two (4.6%) of 43 without deep venous thrombosis (X2: P < 0.02). Of the ten patients who had pulmonary embolism according to this study's criteria (one or more new defect on perfusion, unmatched on the ventilation scan), eight would have been classified as high probability by the Biello criteria, and only five by the PIOPED criteria, if the pre-operative scans were not available. We conclude that having a pre-operative lung scan improves ability to interpret the postoperative lung scans in high risk patients.

Elective Surgical Procedures

Thrombolysis in arterial graft thrombosis.

OBJECTIVE: to assess the impact of peripheral arterial thrombolysis for vascular graft occlusion. DESIGN: Retrospective review. SETTING: University Hospital. MATERIALS: Thirty-one patients presented with 33 episodes of graft thrombosis. CHIEF OUTCOME MEASURES: Successful thrombolysis in terms of total clearance or sufficient clearance to reveal an underlying factor responsible for graft failure. MAIN RESULTS: Thrombolysis was successful in seven of 10 suprainguinal grafts (4 of 5 rtPA; 3 of 5 SK). One patient had failed lysis requiring an ilio-femoral graft. Of the seven patients with successful lysis, one required revision of a proximal anastomosis, two required distal anastomotic revisions, and one rethrombosed. Twenty-three thrombosed infrainguinal grafts were managed initially with intraarterial thrombolysis (9rtPA, 14 SK). Of 27 patients surviving at 30 days, seven required major amputation despite aggressive intervention. CONCLUSIONS: Thrombosed suprainguinal grafts are amenable to thrombolysis and adjunctive surgery when necessary, with no major haemorrhagic complications. The majority of patients with thrombosed infrainguinal grafts require surgical intervention in order to preserve, or establish long term patency. For polytetrafluoroethylene (PTFE) grafts, thrombolysis was associated with poor success, haemorrhagic complications and a high amputation rate.

Amputation, Surgical

Peripheral transluminal angioplasty under ultrasound guidance: initial clinical experience and prevalence of lower limb lesions amenable to ultrasound-guided angioplasty.

PURPOSE: Currently, endovascular techniques require monitoring by radiographic imaging for accurate catheter placement. The aim of this study was first to determine the feasibility of angioplasty under ultrasound guidance using a special catheter system. Based on this outcome, the second goal was to investigate the prevalence of lesions amenable to ultrasound-guided angioplasty. METHODS: A balloon catheter system (Echomark) has been developed, which allows accurate catheter guidance by ultrasound imaging. An ultrasound-sensitive piezoelectric sensor positioned in the middle of the balloon portion of the angioplasty catheter is interfaced to an external duplex scanner via the catheter system. The exact position of the balloon relative to the transducer is calculated and reproduced on the screen of the duplex scanner to guide balloon positioning. In the feasibility assessment of the procedure, 16 patients with disabling claudication and rest pain were selected for balloon angioplasty under ultrasound guidance based on arteriographic and hemodynamic lesion criteria of > 50% stenosis with a peak systolic velocity ration > 2.5 in a lesion < 4 cm long that could be imaged by duplex ultrasonography. A fall in the peak systolic velocity ratio below 2.0 was selected for a procedural endpoint corresponding to < 30% residual stenosis on the completion angiogram. In the second part of the study, the prevalence of stenoses amenable to ultrasound-guided angioplasty was studied in 80 patients presenting with symptoms of peripheral arterial disease. RESULTS: In the feasibility study, 20 stenoses (5 common iliac, 6 external iliac, and 8 superficial femoral arteries and 1 graft) meeting the inclusion criteria were subjected to ultrasound-guided angioplasty with confirmation by completion angiography. The procedure was possible in 18 (90%) of the 20 stenoses. The two failures occurred in iliac arteries that could not be imaged by duplex scanning due to obesity, bowel gas, and/or vessel wall calcification. In one case, the peak systolic velocity ratio exceeded 2.5 despite a satisfactory control arteriogram; redilation was performed, and the ratio fell below 2.0. In the second part of the study, 21 (26.2%) of the 80 patients had 29 stenoses that were amenable to angioplasty according to angiographic criteria (> 50% stenosis and < 4 cm length). All these stenoses were evaluated with duplex scanning to determine their suitability for angioplasty under ultrasound guidance. Twenty-three (79%) of the 29 lesions selected for angioplasty were well visualized by duplex, and angioplasty would have been possible based on our initial clinical experience. CONCLUSIONS: Angioplasty under ultrasound control is a feasible technique for peripheral lesions. Ultrasound allows monitoring of both anatomical and hemodynamic parameters during angioplasty and thus provides a procedural endpoint that correlates to the control angiogram. A large proportion (79%) of stenoses deemed suitable for angioplasty can be well visualized by ultrasound, but obesity, vessel wall calcification, and bowel gas may limit the ability to obtain a satisfactory ultrasound image. Ultrasound-guided angioplasty is a potentially useful procedure that warrants further investigation.

Angioplasty, Balloon

Duplex controlled angioplasty.

Duplex examination was carried out to assess lesions in peripheral arteries amenable to angioplasty. With the help of a special catheter, angioplasty of these lesions was performed under Duplex control. Sixteen patients presenting with claudication were examined by Duplex and 38 lesions were identified (31 stenoses, seven occlusions) and all the findings except one (vessel E1) were confirmed by subsequent angiography. Sixteen lesions were considered amenable to angioplasty and 13 lesions (in 10 patients) were selected for Duplex controlled angioplasty. A new catheter system which has a piezo-electric transducer at the centre of the balloon and integrated to a Duplex scanner via a catheter system interface, was used for the procedure. This allows the exact position of the balloon to be represented on the screen. Thirteen lesions (seven superficial femoral artery (SFA), three external iliac, two common iliac and one graft) were subjected to angioplasty under Duplex control. In one patient, the SFA was punctured directly under ultrasound control as the profunda was diseased. The guide wire was visualised in all cases and in the majority of cases, balloon size for the angioplasty was chosen by measurement of the arterial diameter by Duplex, which was also used for haemodynamic evaluation before, during and after the procedure. Eleven lesions (85%) underwent angioplasty entirely under Duplex control and additional X-ray control was needed in only two cases. In conclusion, Duplex allows the monitoring of both anatomical and haemodynamic parameters during angioplasty. It also reduces the risk of ionising radiation. Our initial experience has been encouraging as angioplasty was performed in the majority of lesions purely under Duplex control.

Angioplasty, Balloon