HDR brachytherapy applied to cervical carcinoma with moderate lateral expansion: modified principles of treatment.

BACKGROUND AND PURPOSE: In order to meet the deficiencies of endocavitary applications, a combined technique was introduced with the aim of achieving better target coverage for improvement of loco-regional tumour control. In high dose rate (HDR) endocavitary applications with tandem and ovoids, enlargement of the distance between the ovoids, shifting of dwell times and also optimization often fail to achieve sufficient expansion of the cervical parametrial area encompassed by the reference isodose. MATERIALS AND METHODS: The Deventer method, whereby HDR endocavitary and HDR interstitial brachytherapy are applied in the same session, was applied for tumours with a lateral expansion of 25 mm or more from the axis of the cervical canal. For the addition of HDR interstitial brachytherapy, each ovoid was provided with a channel which allowed insertion of an afterloading needle into the cervix up to a fixed depth. The dose specifications and dosimetry in neighbouring organs are presented in detail. RESULTS: Seventy-six combined applications were given to 41 patients. The follow-up averaged at 23 months, with a maximum of 59 months. No severe early or persistent late complications were observed. In stage IIB tumours, the most important evaluation of the merits of this technique, the disease-free 3-year survival determined with the Kaplan-Meier method was 75% (n=20). CONCLUSIONS: The Deventer method of HDR endocavitary and HDR interstitial brachytherapy applied in the same session is a feasible method for enlargement of the reference isodose envelope in the cervical parametrial area. The 3-year disease-free survival in stage IIB patients and the low complication rates in all stages together, justify its continuation.

Adult↗

Evaluation of brachytherapy implants using the "natural" volume-dose histogram.

The "natural" volume-dose histogram as described by Anderson visualises graphically even small differences between source arrangements, making it a useful tool to compare planned and realised source configurations. In this study the histogram is applied to demonstrate that the introduction of an applicator in oral cavity implants or of iridium wire spacers used as templates in bladder implants improved the quality of the implants considerably, resulting in close agreement between the planned and the realised source configuration.

Brachytherapy↗

[Breast preserving therapy: shorter treatment duration by the peroperative introduction of iridium guide needles].

In the Deventer Radiotherapeutic Institute from January 1981 through December 1989, 359 patients who had undergone a breast-saving operation were irradiated. Since 1987, iridium guiding needles were introduced peroperatively in 79 of these patients. Subsequently, irradiation was administered. With this method the total duration of treatment was 16 days shorter on average than in patients who postoperatively were treated with iridium or external irradiation; also, the patients treated peroperatively needed only to be anaesthetized once. In addition, better positioning of the needles was possible, reducing the risk of faulty localization. The follow-up was short but the preliminary results of the treatment were good (one local recurrence after an average follow-up of 20 months) and no adverse effect on wound healing was seen.

Adolescent↗

Comparison between predicted and actual dose distribution in interstitial therapy of the oral cavity.

During the period 1985-1986, 10 patients with lesions of the floor of the mouth or of the mobile part of the tongue were treated by interstitial curietherapie with iridium-192. In the patients treated with the looping technique essential differences were found between the predicted source configuration and that actually achieved, resulting in a disagreement between precalculated and actual dose distribution. To avoid this undesirable situation, a simple oral cavity applicator was constructed which guarantees parallelism and equidistance between the implanted needles. It was found that the use of this applicator resulted in an almost complete agreement between forecast and actual dose distribution.

Brachytherapy↗

Dose determination in bladder and rectum during intracavitary irradiation of cervix carcinoma.

The radiation dosage in the base of the bladder and in the anterior wall of the rectum during intracavitary irradiation of cervix carcinoma can be determined easily by use of intracavitary transvesical and transrectal ultrasound and simultaneous radiography. In case of excessive doses to the organs at risk, the dose can be lowered by rearrangement of the vaginal gauze packing in the same sitting.