PubMed Health⌕ Search

Biomedical subjects

A van Hoek

Publications and source records attributed to A van Hoek.

45 records · Page 3Linked to original sources

Time-resolved fluorescence spectroscopy of lumazine protein from Photobacterium phosphoreum using synchrotron radiation.

Time-resolved fluorescence on lumazine protein from Photobacterium phosphoreum was performed with synchrotron radiation as a source of continuously tunable excitation. The experiments yielded structural and dynamic details from which two aspects became apparent. From fluorescence anisotropy decay monitoring of lumazine fluorescence with different excitation wavelengths, the average correlation times were shown to change, which must indicate the presence of anistropic motion of the protein. A similar study with 7-oxolumazine as the fluorescent ligand led to comparable results. The other remarkable observation dealt with the buildup of acceptor fluorescence, also observed with 7-oxolumazine although much less pronounced, which is caused by the finite energy transfer process between the single donor tryptophan and the energy accepting lumazine derivatives. Global analytical approaches in data analysis were used to yield realistic correlation times and reciprocal transfer rate constants. It was found that the tryptophan residue has a large motional freedom as also reported previously for this protein and for the related protein from P. leiognathi (Lee et al. 1985; Kulinski et al. 1987). The average distance between the tryptophan residue and the ligand donor-acceptor couple has been determined to be 2.7 nm for the same donor and two different acceptors.

Bacterial Proteins↗

Time-resolved tryptophan fluorescence anisotropy investigation of bacteriophage M13 coat protein in micelles and mixed bilayers.

Coat protein of bacteriophage M13 is examined in micelles and vesicles by time-resolved tryptophan fluorescence and anisotropy decay measurements and circular dichroism experiments. Circular dichroism indicates that the coat protein has alpha-helix (60%) and beta-structure (28%) in 700 mM sodium dodecyl sulfate micelles and predominantly beta-structure (94%) in mixed dimyristoylphosphatidylcholine/dimyristoylphosphatidic acid (80/20 w/w) small unilamellar vesicles. The fluorescence decay at 344 nm of the single tryptophan in the coat protein after excitation at 295 or 300 nm is a triple exponential. In the micelles the anisotropy decay is a double exponential. A short, temperature-independent correlation time of 0.5 +/- 0.2 ns reflects a rapid depolarization process within the coat protein. The overall rotation of the coat protein-detergent complex is observed in the decay as a longer correlation time of 9.8 +/- 0.5 ns (at 20 degrees C) and has a temperature dependence that satisfies the Stokes-Einstein relation. In vesicles at all lipid to protein molar ratios in the range from 20 to 410, the calculated order parameter is constant with a value of 0.7 +/- 0.1 from 10 to 40 degrees C, although the lipids undergo the gel to liquid-crystalline phase transition. The longer correlation time decreases gradually on increasing temperature. This effect probably arises from an increasing segmental mobility within the coat protein. The results are consistent with a model in which the coat protein has a beta-structure and the tryptophan indole rings do not experience the motion of the lipids in the bilayer because of protein-protein aggregation.

Circular Dichroism↗

Application of a reference convolution method to tryptophan fluorescence in proteins. A refined description of rotational dynamics.

A reference method for the deconvolution of polarized fluorescence decay data is described. Fluorescence lifetime determinations for p-terphenyl, p-bis[2-(5-phenyloxazolyl)]benzene and N-acetyltryptophanamide (AcTrpNH2) show that with this method more reliable fits of the decays can be made than with the scatterer method, which is most frequently used. Analysis of the AcTrpNH2 decay with p-terphenyl as the reference compound yields an excellent fit with lifetimes of 2.985 ns for AcTrpNH2 and 1.099 ns for p-terphenyl (20 degrees C), whereas the AcTrpNH2 decay cannot be satisfactorily fitted when the scatterer method is used. The frequency of the detected photons is varied to determine the conditions where pulse pile-up starts to affect the measured decays. At detection frequencies of 5 kHz and 15 kHz, which corresponds to 1.7% and 5% respectively of the rate of the excitation photons no effects are found. Decays measured at 30 kHz (10%) are distorted, indicating that pile-up effects play a role at this frequency. The fluorescence and fluorescence anisotropy decays of the tryptophan residues in the proteins human serum albumin, horse liver alcohol dehydrogenase and lysozyme have been reanalysed with the reference method. The single tryptophan residue of the albumin is shown to be characterized by a triple-exponential fluorescence decay. The anisotropy decay of albumin was found to be mono-exponential with a rotational correlation time of 26 ns (20 degrees C). The alcohol dehydrogenase has two different tryptophan residues to which single lifetimes are assigned. It is found that the rotational correlation time for the dehydrogenase changes with excitation wavelength (33 ns for lambda ex = 295 nm and 36 ns for lambda ex = 300 nm at 20 degrees C), indicating a nonspherical protein molecule. Lysozyme has six tryptophan residues, which give rise to a triple-exponential fluorescence decay. A single-exponential decay with a rotational correlation time of 3.8 ns is found for the anisotropy. This correlation time is significantly shorter than that arising from the overall rotation and probably originates from intramolecular, segmental motion.

Fluorescence Polarization↗

Determination of rotational correlation times from deconvoluted fluorescence anisotropy decay curves. Demonstration with 6,7-dimethyl-8-ribityllumazine and lumazine protein from Photobacterium leiognathi as fluorescent indicators.

The experimental and analytical protocols required for obtaining rotational correlation times of biological macromolecules from fluorescence anisotropy decay measurements are described. As an example, the lumazine protein from Photobacterium leiognathi was used. This stable protein (Mr 21 200) contains the noncovalently bound, natural fluorescent marker 6,7-dimethyl-8-ribityllumazine, which has in the bound state a long fluorescence lifetime (tau = 14 ns). Shortening of the fluorescence lifetime to 2.6 ns at room temperature was achieved by addition of the collisional fluorescence quencher potassium iodide. The shortening of tau had virtually no effect on the rotational correlation time of the lumazine protein (phi = 9.4 ns, 19 degrees C). The ability to measure biexponential anisotropy decay was tested by the addition of Photobacterium luciferase (Mr 80 000), which forms an equilibrium complex with lumazine protein. Under the experimental conditions used (2 degrees C) the biexponential anisotropy decay can best be described with correlation times of 20 and 60 ns, representing the uncomplexed and luciferase-associated lumazine proteins, respectively. The unbound 6,7-dimethyl-8-ribityllumazine itself (tau = 9 ns) was used as a model compound for determining correlation times in the picosecond time range. In the latter case rigorous deconvolution from the excitation profile was required to recover the correlation time, which was shorter (100-200 ps) than the measured laser excitation pulse width (500 ps).

Bacterial Proteins↗

A subnanosecond resolving spectrofluorimeter for the analysis of protein fluorescence kinetics.

A spectrofluorometer is described consisting of an excitation source, optics, detector and time resolving electronics. The excitation source consists of a mode-locked Ar ion laser, which synchronously pumps a dye laser, followed by a frequency doubling device. The repetition frequency of the U.V. pulses (FWHM some ps) has been reduced by an extra-cavity electro-optical modulator. Provisions have been made in the optical configuration to determine both time-resolved fluorescence spectra and fluorescence anisotropy decay curves. The commercially available electronics have been optimized for maximum time resolution. The spectral output of the excitation source is confined between 280 and 310 nm, which encompasses the region for eliciting protein fluorescence. The performance of the complete system has been tested with single lifetime standards like p-terphenyl in cyclohexane or with N-acetyl-L-tryptophanamide in pH 7.5 buffer. Serum albumins from human and bovine sources have been employed as examples for time resolved fluorescence spectra and for the demonstration of anisotropy decay curves. Using these methods protein dynamics in the (sub)nanosecond time region can be directly explored.

Chemical Phenomena↗

The measurement of subnanosecond fluorescence decay of flavins using time-correlated photon counting and a mode-locked Ar ion laser.

A system is described consisting of a mode-locked Ar ion laser and time-resolved photon-counting electronics. The system is capable of measuring fluorescence lifetimes in the subnanosecond time domain. The Ar ion laser is suitable for the excitation of flavins, since the available laser wavelengths encompass the first absorption band of the yellow chromophore. Due to the high radiation density and the short pulse, both the time and wavelength resolution of the fluorescence of very weakly emitting compounds can be measured. Experiments have been described for flavin models exhibiting single and multiple modes of decay. In these examples lifetimes were determined both from deconvolved decay curves and from direct analysis of the tail of the curve, where no interference of the exciting pulse is encountered. Both determinations showed very good agreement. Due to the highly polarized laser light the decay of the emission anisotropy could be measured directly after the exciting pulse. In principle, fast rotational motions might be detected. An anisotropy measurement conducted with a flavoprotein with a noncovalently attached FAD is presented.

Erythrosine↗

Effect of quinones and phenols on the triple-enzyme bioluminescent system with protease.

The study addressed the effects of redox-active compounds on trypsin activity. Series of organic oxidizers (quinones) and reducers (phenols) were chosen as model redox-active compounds. Trypsin activity was quantified by bioluminescent technique. Interactions of these compounds with trypsin were studied by fluorescent and light absorption methods. Luminescence intensity decay constants in the reduced nicotinamidadeninedinucleotide (NADH): flavinmononucleotide (FMN)-oxidoreductase (R)-luciferase (L)-trypsin (T) (R + L + T) triple-enzyme system were calculated and compared in the presence of different concentrations of quinones and phenols. The triple-enzyme system was shown to be sensitive to quinones and not sensitive to phenols. It has been found that the effects produced by quinones on the coupled enzyme system (R + L) and on the trypsin molecule (T) are not related. The conclusions were extrapolated to the properties of other proteases and antiproteases.

Endopeptidases↗

Characteristics of endogenous flavin fluorescence of Photobacterium leiognathi luciferase and Vibrio fischeri NAD(P)H:FMN-oxidoreductase.

The bioluminescent bacterial enzyme system NAD(P)H:FMN-oxidoreductase-luciferase has been used as a test system for ecological monitoring. One of the modes to quench bioluminescence is the interaction of xenobiotics with the enzymes, which inhibit their activity. The use of endogenous flavin fluorescence for investigation of the interactions of non-fluorescent compounds with the bacterial luciferase from Photobacterium leiognathi and NAD(P)H:FMN-oxidoreductase from Vibrio fischeri has been proposed. Fluorescence spectroscopy methods have been used to study characteristics of endogenous flavin fluorescence (fluorophore lifetime, the rotational correlation time). The fluorescence anisotropy behaviour of FMN has been analysed and compared to that of the enzyme-bound flavin. The fluorescence characteristics of endogenous flavin of luciferase and NAD(P)H:FMN-oxidoreductase have been shown to be applicable in studying enzymes' interactions with non-fluorescent compounds.

Aliivibrio fischeri↗