Aaron Fenster

Publications and source records attributed to Aaron Fenster.

12 recordsLinked to original sources

Three-dimensional ultrasound imaging and its use in quantifying organ and pathology volumes.

Although ultrasonography is an important cost-effective imaging modality, technical improvements are needed before its full potential is realized for accurate and reproducible monitoring of disease progression or regression. Two-dimensional viewing of three-dimensional anatomy, using conventional ultrasonography, limits our ability to quantify and visualize pathology and is partly responsible for the reported variability in diagnosis and monitoring of disease progression. Efforts of investigators have focused on overcoming these deficiencies by developing 3D ultrasound imaging techniques that are capable of acquiring B-mode images using existing conventional ultrasound systems, reconstructing the information into 3D images, and then allowing interactive viewing of the 3D images on inexpensive desktop computers. In addition, the availability of 3D ultrasound images has allowed the development of manual and semi-automated techniques to quantify normal and abnormal anatomical volumes. In this paper we review our semi-automated 3D segmentation approaches for segmenting the surface of the carotid arteries and plaques, and segmenting the prostate. These techniques demonstrate that efficient segmentation techniques can be used with 3D ultrasound images to quantify anatomical organ volumes and morphology.

Carotid Arteries↗

MP3 compression of Doppler ultrasound signals.

The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals.

Algorithms↗

A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies.

The evaluation of new techniques for 2-D and 3-D intravascular ultrasound (US) imaging (IVUS) often requires the use of a pulsating coronary phantom. This study describes the design, construction and evaluation of a phantom simulating the pulsation of a human coronary artery for IVUS studies. Polyvinyl alcohol (PVA) cryogel was used as a tissue mimic for the coronary vessel, which was incorporated in a custom-built assembly. The phantom was programmed to pulsate under servomotor control, to model the pulsation of a normal coronary artery and 2-D IVUS images were obtained using an IVUS imaging catheter. To evaluate the performance of the phantom, the lumen area variation of the phantom was determined and compared with the programmed pulsation waveforms. Our results showed that phantom pulsation correlated well with the programmed pulsation waveform (r = 0.97). The deviation of the least squares line from the line of identity was calculated to be < 4%.

Coronary Vessels↗

Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections.

In this paper, we describe an algorithm to segment a needle from a three-dimensional (3D) ultrasound image by using two orthogonal two-dimensional (2D) image projections. Not only is the needle more conspicuous in a projected (volume-rendered) image, but its direction in 3D lies in the plane defined by the projection direction and the needle direction in the projected 2D image. Hence, using two such projections, the 3D vector describing the needle direction lies along the intersection of the two corresponding planes. Thus, the task of 3D needle segmentation is reduced to two 2D needle segmentations. For improved accuracy and robustness, we use orthogonal projection directions (both orthogonal to a given a priori estimate of the needle direction), and use volume cropping and Gaussian transfer functions to remove complex background from the 2D projection images. To evaluate our algorithm, we tested it with 3D ultrasound images of agar and turkey breast phantoms. Using a 500 MHz personal computer equipped with a commercial volume-rendering card, we found that our 3D needle segmentation algorithm performed in near real time (about 10 fps) with a root-mean-square accuracy in needle length and endpoint coordinates of better than 0.8 mm, and about 0.5 mm on average, for needles lengths in the 3D image from 4.0 mm to 36.7 mm.

Algorithms↗

Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound images.

In this paper, we report on two methods for semiautomatic three-dimensional (3-D) prostate boundary segmentation using 2-D ultrasound images. For each method, a 3-D ultrasound prostate image was sliced into the series of contiguous 2-D images, either in a parallel manner, with a uniform slice spacing of 1 mm, or in a rotational manner, about an axis approximately through the center of the prostate, with a uniform angular spacing of 5 degrees. The segmentation process was initiated by manually placing four points on the boundary of a selected slice, from which an initial prostate boundary was determined. This initial boundary was refined using the Discrete Dynamic Contour until it fit the actual prostate boundary. The remaining slices were then segmented by iteratively propagating this result to an adjacent slice and repeating the refinement, pausing the process when necessary to manually edit the boundary. The two methods were tested with six 3-D prostate images. The results showed that the parallel and rotational methods had mean editing rates of 20% and 14%, and mean (mean absolute) volume errors of -5.4% (6.5%) and -1.7% (3.1%), respectively. Based on these results, as well as the relative difficulty in editing, we conclude that the rotational segmentation method is superior.

Algorithms↗

Statistical analysis of decorrelation-based transducer tracking for three-dimensional ultrasound.

The use of speckle decorrelation techniques to calculate the displacement of a moving transducer has shown promise. We describe a technique to estimate displacement between pairs of parallel planes without assuming that plane separation in the scan is uniform. We perform theoretical and empirical analyses of the bias and uncertainty in plane spacing estimates as a function of speckle size, patch size, and the number of planes used for normalization. Practically, only the central, linear region of the autocovariance curves can be used in this decorrelation method, which implies that distance between acquired image planes should be approximately half the speckle size. In this region, the uncertainty in estimated plane spacing was less than 15% for a 8.1 mm (axial) by 9.1 mm (lateral) patch and increased to 33% for an 8.1 mm (axial) by 1.5 mm (lateral) patch. The number of planes, Nz, used to calculate the normalization factors (averages of brightness and- squared brightness) was a major source of bias. Optimum Nz was found to be five to ten planes, depending on distance between acquired image planes, with a poor choice of Nz resulting in a bias of 10% or greater. A second source of bias is brightness gradients which, although they appear very slight on intensity images, can cause a large bias is the plane spacing estimates made using linearized data.

Algorithms↗

Testing and optimization of a semiautomatic prostate boundary segmentation algorithm using virtual operators.

Image analysis tasks such as size measurement and landmark-based registration require the user to select control points in an image. The output of such algorithms depends on the choice of control points. Since the choice of points varies from one user to the next, the requirement for user input introduces variability into the output of the algorithm. In order to test and/or optimize such algorithms, it is necessary to assess the multiplicity of outputs generated by the algorithm in response to a large set of inputs; however, the input of data requires substantial time and effort from multiple users. In this paper we describe a method to automate the testing and optimization of algorithms using "virtual operators," which consist of a set of spatial distributions describing how actual users select control points in an image. In order to construct the virtual operator, multiple users must repeatedly select control points in the image on which testing is to be performed. Once virtual operators are generated, control points for initializing the algorithm can be generated from them using a random number generator. Although an initial investment of time is required from the users in order to construct the virtual operator, testing and optimization of the algorithm can be done without further user interaction. We illustrate the construction and use of virtual operators by testing and optimizing our prostate boundary segmentation algorithm. The algorithm requires the user to select four control points on the prostate as input.

Algorithms↗

Prostate boundary segmentation from 3D ultrasound images.

Segmenting, or outlining the prostate boundary is an important task in the management of patients with prostate cancer. In this paper, an algorithm is described for semiautomatic segmentation of the prostate from 3D ultrasound images. The algorithm uses model-based initialization and mesh refinement using an efficient deformable model. Initialization requires the user to select only six points from which the outline of the prostate is estimated using shape information. The estimated outline is then automatically deformed to better fit the prostate boundary. An editing tool allows the user to edit the boundary in problematic regions and then deform the model again to improve the final results. The algorithm requires less than 1 min on a Pentium III 400 MHz PC. The accuracy of the algorithm was assessed by comparing the algorithm results, obtained from both local and global analysis, to the manual segmentations on six prostates. The local difference was mapped on the surface of the algorithm boundary to produce a visual representation. Global error analysis showed that the average difference between manual and algorithm boundaries was -0.20 +/- 0.28 mm, the average absolute difference was 1.19 +/- 0.14 mm, the average maximum difference was 7.01 +/- 1.04 mm, and the average volume difference was 7.16% +/- 3.45%. Variability in manual and algorithm segmentation was also assessed: Visual representations of local variability were generated by mapping variability on the segmentation mesh. The mean variability in manual segmentation was 0.98 mm and in algorithm segmentation was 0.63 mm and the differences of about 51.5% of the points comprising the average algorithm boundary are insignificant (P < or = 0.01) to the manual average boundary.

Algorithms↗

A real-time biopsy needle segmentation technique using Hough transform.

Real-time needle segmentation and tracking is very important in image-guided surgery, biopsy, and therapy. Due to its robustness to the addition of extraneous noise, the Hough Transform is one of the most powerful line-detection techniques nowadays and has been widely used in different areas. Unfortunately, its high computation needs often prevent it from being applied in real-time applications without the help of specially designed hardware. In order to solve this problem, a variety of fast implementation algorithms have been proposed. However, none of them can be performed in a real time on an affordable computer. In this paper, we describe a fast implementation of the Hough Transform based on coarse-fine search and the determination of the optimal image resolution. Compared to conventional techniques, our approach decreases the time for needle segmentation by an order of magnitude. Experiments with agar phantom and patient breast biopsy ultrasound (US) image sequences showed that our approach can segment the biopsy needle in real time (i.e., less than 33 ms) on an affordable PC computer without the help of specially designed hardware with the angular rms error of about 1 degrees and the position rms error of about 0.5 mm.

Agar↗

Comparison of core needle breast biopsy techniques: freehand versus three-dimensional US guidance.

RATIONALE AND OBJECTIVES: No single method is generally accepted for evaluating the accuracy of breast biopsy techniques before their clinical implementation. The purpose of this study was to test a new process for evaluating biopsy techniques by using it in the evaluation of a prototype three-dimensional ultrasound (US)-guided biopsy device. MATERIALS AND METHODS: The biopsy accuracy of a new three-dimensional US-guided breast biopsy device was compared to that of the accepted clinical practice of biopsy by expert radiologists with two-dimensional freehand US guidance. Biopsies were performed in chicken tissue phantoms containing 3.2-mm lesions made of poly(vinyl alcohol) cryogel. The criterion for a successful biopsy was the presence of lesion in the sample. The equivalence limit difference tested was 10% by using a power of 90% and a two-sided test significance level, a, of 10%. RESULTS: The biopsy success rate of the three-dimensional US-guided system (96%) was equivalent to that of expert radiologists using two-dimensional freehand US guidance (94.5%) in tissue phantoms containing poly(vinyl alcohol) cryogel lesions. CONCLUSION: This evaluation procedure is a valuable precursor to clinical trials in the assessment of biopsy techniques. The three-dimensional US-guided breast biopsy system provides a suitable alternative to two-dimensional freehand US guidance for biopsy of breast cancer.

Animals↗

Theoretical and experimental quantification of carotid plaque volume measurements made by three-dimensional ultrasound using test phantoms.

An accurate technique that exhibits low variability has practical importance for the quantification of carotid plaque volume. Such a technique is necessary to monitor plaque progression or regression that may result in response to nonsurgical therapy. In this study, we investigate the accuracy and variability of plaque volume measurement by three-dimensional ultrasound using vascular plaque phantoms over a range of 68.2 mm3 to 285.5 mm3. The agar plaques maintained a consistent cylindrical geometry with variations in the height, length, and echogenicity. The volume of each plaque was determined by water displacement. The three-dimensional (3D) ultrasound (US) images were acquired with a mechanical scanning system which creates a 3D US Cartesian volume, that was manipulated and viewed in any orientation, from a collection of conventional parallel two-dimensional (2D) US images. The plaque volumes were measured by serial 2D manual planimtery. The mean accuracy in plaque volume measurement was 3.1+/-0.9%. Variability in plaque volume measurement was calculated to be 4.0+/-1.0% and 5.1+/-1.4% for intraobserver and interobserver measurements, respectively. We have also developed a theoretical description for the variance in measurement of plaque volume using manual planimetry. Root-mean-square difference between experimentally and theoretically determined values of plaque volume fractional variance was 9%.

Analysis of Variance↗

Three dimensional transrectal ultrasound imaging of the prostate: initial experience with an emerging technology.

PURPOSE: A three-dimensional ultrasound system (3-D US) was evaluated for its clinical utility in transrectal prostate imaging, in comparison with the current standard 2-dimensional transrectal ultrasound (TRUS) imaging system. METHODS AND MATERIALS: The computer program developed in our laboratory was coupled with a commercially available ultrasound transducer. Geometric validation and volumetric assessment was performed with "stretched-string" wire models and solution-containing balloons respectively. Anatomic correlation of 3-D TRUS images was performed with cadaveric prostates. Intraprostatic lesion localization by 3D-TRUS was assessed clinically by 2 observers in 11 patients prior to radical prostatectomy and the data compared with those yielded by 2-D TRUS. RESULTS: Geometric assessment by 3D TRUS in comparison with the "between strings in the phantom" model (true dimensions) had an error of up to 1.2%. Volume measurement by 3-D TRUS had an error, compared to the true volume, of 0.9%. The correlation coefficient (r) was 0.99985 for the end-firing probe and 0.978 for side firing. The 3-D images provided accurate representation of the true anatomy in the sagittal, transverse and most uniquely, the coronal plane. Two observers achieved better diagnostic accuracies with intraprostatic abnormalities using 3-D instead of standard 2-D TRUS. The negative predictive value and the specificity were improved. CONCLUSION: 3-D TRUS appears to provided accurate representation of the true anatomy with geometric and volumetric validation. Areas of potential clinical application of 3-D TRUS include treatment monitoring with volume measurements and various intervention and therapeutic procedures for both benign and malignant prostatic disorders.

Journal Article↗