Aaron J Parkinson

Publications and source records attributed to Aaron J Parkinson.

3 recordsLinked to original sources

The nucleus 24 contour cochlear implant system: adult clinical trial results.

OBJECTIVE: The purpose of this article is to present psychophysical data for 40 Nucleus 24 Contour adult patients with 1 mo of device experience and speech perception results for a group of 56 adult patients with 3 mo experience using the Nucleus 24 Contour cochlear implant system. Postoperative hearing thresholds (i.e., under headphones) in the implanted ear were also assessed in a group of 85 patients who had measurable hearing preoperatively. This was of interest because preservation of residual hearing, postoperatively, is consistent with atraumatic insertion of the electrode array. In addition, data will be presented that reflected feedback from 40 surgeons who participated in the trial. DESIGN: Participants in this study were 18 yr of age or older, with bilateral severe to profound sensorineural hearing loss with no congenital component. Preoperatively, they scored < or = 50% open-set sentence recognition (HINT sentences) in the ear to be implanted and < or = 60% in the best-aided condition. The investigation was a repeated-measures single-subject experiment and took place at 46 different North American clinical sites. Preoperative performance was compared with postoperative performance 3 mo after device activation. Clinicians were able to program patients' processors with one, two, or all three speech-processing strategies. Testing took place using the participant's preferred speech-processing strategy (SPEAK, CIS, or ACE). Preoperative unaided hearing thresholds were compared with unaided thresholds in the implanted ear measured 1 mo after device activation. Surgeons were canvassed regarding surgical use and design of the device via a questionnaire after having completed at least one Nucleus 24 Contour surgery. RESULTS: Average T- and C-levels for the Nucleus 24 Contour patients were considerably lower than those using the Nucleus 24 (CI24M). A total of 85 patients had measurable hearing preoperatively at two or more audiometric frequencies in the ear implanted. Of these patients 41 (48%) had measurable hearing at one or more frequencies and 32 (38%) had measurable hearing at two or more frequencies postoperatively. In general, surgeons found the Nucleus 24 Contour easy to insert and were pleased with the design features of the device. The downsized receiver/stimulator (of the Nucleus 24 Contour) required less drilling than the Nucleus 24, reducing surgical time, as well as making the Contour better suited for implantation in those with small skull sizes (e.g., small children and infants). After 3 mo of device use, mean open-set speech perception in quiet and in noise was significantly better than preoperative performance on all test measures. Patients using the ACE strategy had significantly better mean scores for all measures than patients using SPEAK. Only two patients preferred to use the CIS coding strategy. CONCLUSIONS The results presented in this article demonstrated that the design objectives of the Nucleus 24 Contour were met. Namely, results from this study, together with insertion studies, were consistent with perimodiolar placement using an implant design that the majority of surgeons found easy to insert with relatively minimal trauma. Reduced T- and C-levels were observed with Contour patients when compared with patients using the Nucleus 24 with the straight array, consistent with perimodiolar placement. A survey of surgeons participating in the clinical trial indicated easier, or equally easy, insertion of the Contour array, compared with previous Nucleus products as well as other manufacturers' devices, without the use of additional insertion tools or array positioners. Postoperatively, 46% of patients with preoperative residual hearing maintained some level of unaided hearing postoperatively, suggesting atraumatic insertion of the Nucleus 24 Contour electrode array. It is worth noting that all 216 patients implanted during this study had full insertions of their Contour electrode arrays. High levels of open-set speech perception in quiet and in noise were achieved and patients using the ACE strategy had significantly better mean scores for all measures than patients using SPEAK. Only two patients preferred to use the CIS coding strategy.

Acoustic Stimulation↗

Three-month results with bilateral cochlear implants.

OBJECTIVES: To evaluate possible binaural listening advantages for speech in quiet, speech in noise, and for localization in a group of postlingually deafened adults with two cochlear implants functioning independently after 3 mo experience. DESIGN: Nine postlingually deafened subjects who had received a Cochlear Corporation CI24M implant in each ear were evaluated on a number of tasks. The subjects all had audiometric or biographical (e.g., duration of deafness) differences between the ears. Word and sentence materials were presented to the subjects in quiet and in noise with the signal always in the front and the noise from the front or either side. Results are reported for each ear and for both ears with the noise on either side. This allowed evaluation of head shadow and squelch effects. Additionally, localization ability was assessed for broadband noise presented either to the right or left of center at 45 degrees azimuth. Localization was assessed for each ear and for both ears. RESULTS: Results of speech testing in quiet showed a significant advantage for the binaural condition over the better ear in four subjects. In noise, with both signal and noise in front of the subject, a significant advantage of two ears over the better ear was found for four subjects. For noise to one side of the head, when the ear opposite the noise source was added to the ear ipsilateral to the noise, a significant advantage was demonstrated for seven of seven tested subjects. When the ear ipsilateral to the noise was added to the ear contralateral to the noise, a significant advantage was shown for only one of seven (noise on right) and three of seven (noise on left) tested subjects. The localization task showed that all seven tested subjects could discriminate 45 degrees left from 45 degrees right above chance with bilateral stimulation. Three subjects could perform the discrimination above chance with only one ear. However, performance with both ears was significantly better than performance with one ear for two of these latter subjects. CONCLUSIONS: We conclude that bilateral cochlear implants can provide real advantages, particularly when it is possible to utilize the ear that is away from a noise source, thus taking advantage of the head shadow effect. In addition, localization ability was generally better with two implants than with one.

Acoustic Stimulation↗

Patients utilizing a hearing aid and a cochlear implant: speech perception and localization.

OBJECTIVE: The purpose of this pilot study was to document speech perception and localization abilities in patients who use a cochlear implant in one ear and a hearing aid in the other ear. DESIGN: We surveyed a group of 111 cochlear implant patients and asked them whether they used a hearing aid on their unimplanted ear. The first three patients who were available were tested on word and sentence recognition and localization tasks. Speech stimuli were presented from the front in quiet and in noise. In the latter conditions, noise was either from the front, the right, or the left. Localization was tested with noise bursts presented at 45 degrees from the right or left. In addition we asked the patients about their abilities to integrate the information from both devices. RESULTS: Speech perception tests in quiet showed a binaural advantage for only one of the three patients for words and none for sentences. With speech and noise both in front of the patient, two patients performed better with both devices than with either device alone. With speech in front and noise on the hearing aid side, no binaural advantage was seen, but with noise on the cochlear implant side, one patient showed a binaural advantage. Localization ability improved with both devices for two patients. The third patient had above-chance localization ability with his implant alone. CONCLUSIONS: A cochlear implant in one ear and a hearing aid in the other ear can provide binaural advantages. The patient who did not show a clear binaural advantage had the poorest hearing aid alone performance. The absolute and relative levels of performance at each ear are likely to influence the potential for binaural integration.

Cochlear Implants↗