PubMed Health⌕ Search

Biomedical subjects

Aaron Sin

Publications and source records attributed to Aaron Sin.

7 recordsLinked to original sources

Microfluidic diffusive filter for apheresis (leukapheresis).

Apheresis is a procedure used to fractionate whole blood into its individual components. Following fractionation, the desired component is isolated and the remaining blood in many cases is returned to the donor. Leukapheresis is one type of apheresis where leukocytes (white blood cells) are selectively removed. This procedure is commonly used for blood transfusions to remove donor leukocytes from being transferred to the recipient. Apheresis also has several therapeutic applications. In this manuscript we discuss the design, fabrication and testing of a continuous flow diffusive filter, fabricated using simple soft lithographic techniques for depletion of leukocytes. This device employs micro sieves that exploit the size and shape difference between the different cell types to obtain depletion of leukocytes from whole blood. Currently, conventional apheresis methods like centrifugation or fiber mesh filtration are commonly used. A theoretical model was developed to determine the optimal shape of the diffuser to ensure that the volumetric flow through individual sieve elements is equal. This device was designed to serve as a passive device that does not require any external manipulation. Results show that for the given device design, isolation of approximately 50% of the inlet erythrocytes (red blood cells), along with depletion of >97% of the inlet leukocytes is possible at a flow rate of 5 microl min(-1). Simple modifications to the geometry and dimensions of the sieves can be made to obtain isolation of plasma.

Blood Component Removal↗

Enrichment using antibody-coated microfluidic chambers in shear flow: model mixtures of human lymphocytes.

Isolation of phenotypically-pure cell subpopulations from heterogeneous cell mixtures such as blood is a difficult yet fundamentally important task. Current techniques such as fluorescent activated cell sorting (FACS) and magnetic-activated cell sorting (MACS) require pre-incubation with antibodies which lead to processing times of at least 15-60 min. In this study, we explored the use of antibody-coated microfluidic chambers to negative deplete undesired cell types, thus obtaining an enriched cell subpopulation at the outlet. We used human lymphocyte cell lines, MOLT-3 and Raji, as a model system to examine the dynamic cell binding behavior on antibody coated surfaces under shear flow. Shear stress ranging between 0.75 and 1.0 dyn/cm2 was found to provide most efficient separation. Cell adhesion was shown to follow pseudo-first order kinetics, and an anti-CD19 coated (Raji-depletion) device with approximately 2.6 min residence time was demonstrated to produce 100% pure MOLT-3 cells from 50-50 MOLT-3/Raji mixture. We have developed a mathematical model of the separation device based on the experimentally determined kinetic parameters that can be extended to design future separation modules for other cell mixtures. We conclude that we can design microfluidic devices that exploits the kinetics of dynamic cell adhesion to antibody coated surfaces to provide enriched cell subpopulations within minutes of total processing time.

Antibodies↗

Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers.

Phenotypically pure subpopulations of lymphocytes can provide valuable insights into the immune response to injury and disease. The isolation of these subpopulations presents unique challenges, particularly when preprocessing incubation to attach fluorescent or antibody tags is to be minimized. This paper examines the separation of T and B lymphocytes from mixtures using microfluidic chambers coated with antibodies, focusing on flow conditions and surface chemistry. The adhesion of both cell types decreases as shear stress increases irrespective of the surface chemistry. The incorporation of poly(ethylene glycol) chains along with the antibodies on the chamber surface is shown to significantly improve the reproducibility of cell adhesion and is thus an important part of the overall system design. Furthermore, this technique is shown to be an effective way of isolating highly pure subpopulations of lymphocytes from model mixtures, even when the target cell concentration is low.

Antibodies↗

Development of a microfabricated cytometry platform for characterization and sorting of individual leukocytes.

Organizing leukocytes into high-density arrays makes these cells amenable to rapid optical characterization and subsequent sorting, pointing to clinical and basic science applications. The present paper describes development of a cytometry platform for creating high-density leukocyte arrays and demonstrates retrieval of single cells from the array. Poly(ethylene glycol)(PEG) photolithography was employed to fabricate arrays of microwells composed of PEG hydrogel walls and glass attachment pads 20 microm x 20 microm and 15 microm x 15 microm in size. PEG micropatterned glass surfaces were further modified with cell-adhesive ligands, poly-L-lysine, anti-CD5 and anti-CD19 antibodies, in order to engineer specific cell-surface interactions within the individual wells. Localization of the fluorescently-labeled proteins in the glass attachment pads of PEG microwells was visualized by fluorescence microscopy. Glass slides micropatterned with PEG and cell-adhesive ligands were exposed to T-lymphocytes for 30 min. These anchorage-independent cells became selectively captured in the ligand-modified microwells forming high-density cell arrays. Cell occupancy in the microwells was found to be antibody-dependent, reaching 94.6 +/- 2.3% for microwells decorated with T-cell specific anti-CD5 antibodies. Laser capture microdissection (LCM) was investigated as a method for sorting cells from the array and retrieval of single selected cells was demonstrated.

B-Lymphocytes↗

A self-priming microfluidic diaphragm pump capable of recirculation fabricated by combining soft lithography and traditional machining.

Fluid transport is crucial in the development of microanalytical devices. While there are many micropump designs available, most are incapable of sustaining recirculation of fluid at microL/min to mL/min levels. We have designed and fabricated a positive displacement micropump by combining soft lithography with traditional bulk machining. The micropump is actuated through pneumatic pressure. The pump is self-priming and is suitable for recirculating fluid through a microfluidic device containing mammalian cell culture. By custom designing the volume of the pumping chamber, tight control of the output flow rate can be obtained by changing the actuation frequency. It can also be fabricated easily on plastic substrates without access to expensive microfabrication equipment.

Cell Culture Techniques↗

The design and fabrication of three-chamber microscale cell culture analog devices with integrated dissolved oxygen sensors.

Whole animal testing is an essential part in evaluating the toxicological and pharmacological profiles of chemicals and pharmaceuticals, but these experiments are expensive and cumbersome. A cell culture analog (CCA) system, when used in conjunction with a physiologically based pharmacokinetic (PBPK) model, provides an in vitro supplement to animal studies and the possibility of a human surrogate for predicting human response in clinical trials. A PBPK model mathematically simulates animal metabolism by modeling the absorption, distribution, metabolism, and elimination kinetics of a chemical in interconnected tissue compartments. A CCA uses mammalian cells cultured in interconnected chambers to physically represent the corresponding PBPK. These compartments are connected by recirculating tissue culture medium that acts as a blood surrogate. The purpose of this article is to describe the design and basic operation of the microscale manifestation of such a system. Microscale CCAs offer the potential for inexpensive, relatively high throughput evaluation of chemicals while minimizing demand for reagents and cells. Using microfabrication technology, a three-chamber ("lung"-"liver"-"other") microscale cell culture analog (microCCA) device was fabricated on a 1 in. (2.54 cm) square silicon chip. With a design flow rate of 1.76 microL/min, this microCCA device achieves approximate physiological liquid-to-cell ratio and hydrodynamic shear stress while replicating the liquid residence time parameters in the PBPK model. A dissolved oxygen sensor based on collision quenching of a fluorescent ruthenium complex by oxygen molecules was integrated into the system, demonstrating the potential to integrate real-time sensors into such devices.

Animals↗

Development of a microscale cell culture analog to probe naphthalene toxicity.

Prediction of human response to drugs or chemicals is difficult as a result of the complexity of living organisms. We describe an in vitro model that can realistically and inexpensively study the adsorption, distribution, metabolism, elimination, and potential toxicity (ADMET) of chemicals. A microscale cell culture analog (microCCA) is a physical replica of the physiologically based pharmacokinetics (PBPK) model. Such a microfabricated device consists of a fluidic network of channels to mimic the circulatory system and chambers containing cultured mammalian cells representing key functions of animal "organ" systems. This paper describes the application of a two-cell system, four-chamber microCCA ("lung"-"liver"-"other tissue"-"fat") device for proof-of-concept study using naphthalene as a model toxicant. Naphthalene is converted into reactive metabolites (i.e., 1,2-naphthalenediol and 1,2-naphthoquinone) in the "liver" compartment, which then circulate to the "lung" depleting glutathione (GSH) in lung cells. Such microfabricated in vitro devices are potential human surrogates for testing chemicals and pharmaceutics for toxicity and efficacy.

Animals↗