PubMed Health⌕ Search

Biomedical subjects

Aaron T Timperman

Publications and source records attributed to Aaron T Timperman.

10 recordsLinked to original sources

Identification of hnRNPs K, L and A2/B1 as candidate proteins involved in the nutritional regulation of mRNA splicing.

Nutrient regulation of glucose-6-phosphate dehydrogenase (G6PD) expression occurs through changes in the rate of splicing of G6PD pre-mRNA. This posttranscriptional mechanism accounts for the 12- to 15-fold increase in G6PD expression in livers of mice that were starved and then refed a high-carbohydrate diet. Regulation of G6PD pre-mRNA splicing requires a cis-acting element in exon 12 of the pre-mRNA. Using RNA probes to exon 12 and nuclear extracts from livers of mice that were starved or refed, proteins of 60 kDa and 37 kDa were detected bound to nucleotides 65-79 of exon 12 and this binding was decreased by 50% with nuclear extracts from refed mice. The proteins were identified as hnRNPs K, L, and A2/B1 by LC-MS/MS. The decrease in binding of these proteins to exon 12 during refeeding was not accompanied by a decrease in the total amount of these proteins in total nuclear extract. HnRNPs K, L and A2/B1 have known roles in the regulation of mRNA splicing. The decrease in binding of these proteins during treatments that increase G6PD expression is consistent with a role for these proteins in the inhibition of G6PD mRNA splicing.

Animals↗

ESI-MS compatible permanent coating of glass surfaces using poly(ethylene glycol)-terminated alkoxysilanes for capillary zone electrophoretic protein separations.

Thin poly(ethylene glycol) silane (PEG-silane) coatings formed from N-(triethoxysilyl propyl)-O-poly(ethylene oxide) urethane with different chain lengths of poly(ethylene glycol) (MW 750 and 4000-5000) are used to modify glass microfluidic channels and fused-silica capillaries for electrophoretic separations of proteins. These coatings combine three important properties, which make them favorable for proteomic analyses including reduction of protein adsorption, compatibility with mass spectrometry due to their stability, and the ability to control the magnitude of electroosmotic flow (EOF). The coatings have been successfully used in microfluidic chips and fused-silica capillaries for separation of protein sample mixtures under low EOF conditions. The long-chain and mixed PEG-silane coatings suppress electroosmotic flow by more than 90%, whereas the short-chain PEG silane suppresses EOF by 65-75% at pH values of 3-9. The long-chain and mixed PEG-silane coatings are suitable for low EOF applications or for cases where negative effects of EOF are to be minimized. Efficient separations of unlabeled basic proteins at low pH and FITC-labeled proteins at high pH were achieved, as well as excellent stability for at least 200 electrophoretic runs. Additionally, these covalent coatings produce no detectable background ions in ESI-MS, making them compatible with on-line mass spectrometry.

Electrophoresis, Capillary↗

Interfacing microchip capillary electrophoresis with electrospray ionization mass spectrometry.

Microfluidic devices are a unique enabling technology for chemical separations, modification, and synthesis that are ideally suited for the manipulation of low volume samples on the order of a few nanoliters in volume. Complex patterns of capillary-sized channels with zero dead volume connections are the distinguishing features of many microfluidic devices. Concurrently, mass spectrometry has undergone further development, and is now arguably the method of choice for structural characterization of mass- and volume-limited samples. The production of ions in the gas phase from the solution phase is critical for direct coupling of fluidic devices with the mass spectrometer, and the electrospray ionization (ESI) sources are well suited for this application. Micro- and nanoflow ESI interfaces are ideal for these applications as they cover flow rate ranges from the hundreds to a few nanoliters per minute, which are the same as the flow rates used by most microfluidic devices. Herein, the assembly and operation of a simple ESI interface for coupling a microfluidic device and mass spectrometer is described.

Electrophoresis, Microchip↗

An electrokinetic/hydrodynamic flow microfluidic CE-ESI-MS interface utilizing a hydrodynamic flow restrictor for delivery of samples under low EOF conditions.

A hydrodynamic flow restrictor (HDR) that is used to combine electrokinetic and hydrodynamic flow streams has been fabricated in a microfluidic channel by laser micromachining. Combining electrokinetic and hydrodynamic flow streams is challenging in microfluidic devices, because the hydrodynamic flow often overpowers the electrokinetic flow, making it more difficult to use low electroosmotic flow in the electrokinetic portion of the system. The HDR has been incorporated into a capillary electrophoresis-mass spectrometry interface that provides continuous introduction of a make-up solution and negates the hydrodynamic backpressure in the capillary electrophoresis channel to the extent that low EOF can be utilized. Moreover, the hydrodynamic backpressure is sufficiently minimized to allow coatings that minimize EOF to be used in the electrokinetically driven channel. Such coatings are of great importance for the analysis of proteins and other biomolecules that adsorb to charged surfaces.

Electrophoresis, Capillary↗

Isolation of naturally occurring aluminium ligands using immobilized metal affinity chromatography for analysis by ESI-MS.

Aluminium (iii) is one of the most abundant metal ions found in soil. Typically, Al(+3) is bound to minerals, but its bioavailability and toxicity toward vascular plants increases with increasing soil acidity. Ectomycorrhizal fungi, which live symbiotically on the roots of numerous woody plants, often confer Al(+3) resistance to host plants by reducing metal availability to the plant by unknown mechanisms. A potential mechanism of detoxification is binding of the Al(+3) by organic compounds that are exuded by the fungi into the surrounding soil and solution. A novel method has been developed to purify and characterize Al(+3) binding ligands from Pisolithus tinctorius exudate solutions using Al(+3) immobilized metal affinity chromatography (IMAC), reversed phase chromatography, and mass spectrometry. Fungal exudates produced by P. tinctorius exhibit a strong binding capacity for Al(+3), allowing their selective enrichment and collection using this IMAC method. Elution of the ligands requires the use of high pH. RP-HPLC separation and elemental analysis of the IMAC elutent indicates that the Al(+3) and the exudate ligands both elute from the column but are not bound in a complex. Thus, reversed phase HPLC at pH 10 is used for separation of the ligands and Al(+3) prior to MS analysis. The strongest binding IMAC fraction is analyzed by electrospray ionization mass spectrometry in positive and negative ion modes. This report provides new methods for the direct purification and analysis of naturally occurring ligands that bind hard metal ions.

Aluminum↗

Fabrication and characterization of a fritless microfabricated electroosmotic pump with reduced pH dependence.

A fritless electroosmotic pump with reduced pH dependence has been fabricated on a glass microchip and its performance characterized. The chip design consists of two 500-microm channels, one packed with anion exchange beads and the other packed with cation exchange beads, which produce convergent electroosmotic flow streams. The electroosmotically pumped solution flows away from the intersection of the two pumping channels through a field-free channel. This simple design allows for the production of a fritless electroosmotic pump and easy replacement of the ion exchange beads whose charged surfaces generate the flow. The pump was found to produce volumetric flow rates of up to 2 microL/min for an applied voltage of 3 kV at a pH of 6.8. Moreover, the electroosmotic pump can generate high flow rates over an extended pH range of at least 2-12, a significant advantage over previously fabricated electroosmotic pumps, which typically have a more limited range in which they can achieve high flow rates.

Anion Exchange Resins↗

Low-molecular-weight human serum proteome using ultrafiltration, isoelectric focusing, and mass spectrometry.

Identification of the serum proteome is a daunting analytical task due to the complex nature of the sample which has an extremely large dynamic range of protein components. This report addresses this issue by using centrifugal ultrafiltration to enrich the low-molecular-weight (LMW) serum proteome while decreasing the amount of abundant high-molecular-weight proteins. Reduction of the complex nature of the sample was achieved by fractionation of the LMW serum proteins using solution-phase isoelectric focusing (IEF). Multiple enzyme digestions are performed and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Analysis of the tandem mass spectra resulted in the identification of 262 proteins belonging to LMW serum proteome. Our results demonstrate the effectiveness of this methodology to isolate and identify LMW proteins with improved confidence in the MS data acquired. In addition, our methodology can be combined with other multidimensional chromatography techniques performed on the peptide level to increase the number of identified proteins.

Chymotrypsin↗

Proteome analysis.

Explore the source record for details and available documents.

Chromatography, High Pressure Liquid↗

Integration of nanocapillary arrays into microfluidic devices for use as analyte concentrators.

A nanocapillary array was integrated into a microfluidic device and its ability to concentrate analytes was characterized. Through the application of an electric field across the channel, large molecules were concentrated in front of the nanocapillary array, and a concentrated analyte band was ejected from the channel by reversing the polarity of the electric field. The effects of nanocapillary diameter, analyte charge, analyte concentration, analyte plug length, and analyte relative mobility were investigated. Concentration factors up to 300-fold were measured for fluorescein. By concentrating anionic FITC-labeled peptides, it was demonstrated that the magnitude of the electrophoretic mobility did not have a measurable effect on the concentration factor. Therefore, multiple analytes can be concentrated in front of the same nanocapillary array without adjusting the conditions, provided the analytes have the same net charge. In the presence of an electric field, a charge trapping effect was observed; small anionic molecules can be concentrated in front of nanocapillary array with channel diameters which are orders of magnitude above the molecular weight cut-offs for hydrodynamically driven systems. The concentrating process was found to be very efficient for fluorescein, as no leakage through the nanocapillary array or sorption of fluorescein to the nanocapillary array was observed. Due to their flexibility and efficiency, it is anticipated that nanocapillary arrays will find increased utility in electrokinetically driven microfluidic systems.

Electrophoresis↗

Reversed-phase HPLC separation of human serum employing a novel saw-tooth gradient: toward multidimensional proteome analysis.

A novel reversed-phase (RP-) HPLC gradient profile applicable to multidimensional separations of complex protein mixtures is reported. This gradient profile elutes small numbers of proteins from the RP-HPLC column in discrete intervals while minimizing the amount of band broadening between elution intervals and maintaining constant flow through the HPLC column. Eluting the proteins in discrete intervals eases the instrumental requirements necessary for performing multidimensional separations and can be used to aid in the collection of well-defined fractions. The saw-tooth gradient was applied to the successful isolation of albumin from less abundant proteins in whole human serum and provides adequate separation of proteins in a low-molecular weight (LMW) fraction of human serum with resolution comparable to that achieved using a typical linear gradient profile.

Blood Proteins↗