PubMed Health⌕ Search

Biomedical subjects

Abdil Ozdemir

Publications and source records attributed to Abdil Ozdemir.

6 recordsLinked to original sources

Chemometric determination of naproxen sodium and pseudoephedrine hydrochloride in tablets by HPLC.

A new chemometric determination by high-performance liquid chromatography (HPLC) with photodiode array (PDA) detection was implemented for the simultaneous determination of naproxen sodium and pseudoephedrine hydrochloride in tablets. Three chemometric calibration techniques, classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS) were applied to the peak area at multiwavelength PDA detector responses. The combinations of HPLC with chemometric calibration techniques were called HPLC-CLS, HPLC-PCR and HPLC-PLS. For comparison purposes the HPLC method called the classic HPLC method was used to confirm the results obtained from combined HPLC-chemometric calibration techniques. A good chromatographic separation between two drugs with losartan potassium as an internal standard was achieved using a Waters Symmetry C18 Column 5 microm 4.6+/-250 mm and a mobile phase containing 0.2 M acetate buffer and acetonitrile (v/v, 40:60). The multiwavelength PDA detection was measured at five different wavelengths. The chromatograms were recorded as a training set in the mobile phase. Three HPLC-chemometric calibrations and the classic-HPLC method were used to test the synthetic mixtures of naproxen sodium and pseudoephedrine hydrochloride in the presence of the internal standard. The HPLC-chemometric approaches were applied to real samples containing drugs of interest. The experimental results obtained from HPLC-chemometric calibrations were compared with those obtained by a classic HPLC method.

Anti-Inflammatory Agents, Non-Steroidal↗

UVRR spectroscopic studies of valinomycin complex formation in different solvents.

We investigated the complexation of valinomycin (VM) in different solvent environments with the aid of the UVRR spectroscopy. By probing the 206.5 and 229 nm excited Raman spectra, we showed that new bands are observed around 1700 and 1290 cm(-1). We assigned the 1700 cm(-1) band to the hydrogen bonded ester carbonyl stretching vibration. In a polar solvent, VM-K(+) complexation shows significant intensity changes in amide and ester carbonyl stretching region. Because of the small amount of conformational interconversion, complexation has a negligible effect on other band intensities including, the amide III, C(alpha)H, and amide II. We also showed the effects of the solvent polarity on the solution conformation of VM.

Deuterium↗

Mathematical algorithms applied to the multi-linear regression functions for the multicomponent determination of pharmaceutical dosage form containing three-component mixtures.

In the presence of closely overlapping spectra, the quantitative multiresolution of ternary mixtures of three active compounds paracetamol (PAR), caffeine (CAF) and acetylsalycilic acid (ASP) in tablets, without using pretreatment such as separation step and graphical procedure of spectra was accomplished by the multivariate spectral calibration models, tri-linear regression calibration (TLRC), multi-linear regression calibration (MLRC) and Cramer's rule solution (CRS) of three linear equation functions in the matrix form. In the first two models, TLRC and MLRC are based on the use of the linear regression functions at selected wavelength sets in the spectral region of 210-300 nm. In the case of CRS model, A1(1) (1%, 1 cm) were used to obtain three linear equation functions and this linear equation system was resolved by the Cramer's rule for the prediction of PAR, CAF and ASP in samples. In the TLRC and CRS models, the selection of the appropriate wavelength set was performed by the Kaiser's technique. The algorithms of these mathematical calibration models were briefly described. The validation of TLRC, MLRC and CRS models was carried out by analyzing various synthetic ternary mixtures and by using the standard addition technique. These three calibration approaches were applied to the analysis of the real pharmaceutical tablets containing PAR, CAF and ASP. The obtained results were statistically compared with each other by using experimental and statistical tests. In the comparison of TLRC and MLRC models to the classical approach, CRS technique, the successful assay results were observed for the quantitative multiresolution of ternary mixture of the subject active compounds.

Acetaminophen↗

Comparative study of the continuous wavelet transform, derivative and partial least squares methods applied to the overlapping spectra for the simultaneous quantitative resolution of ascorbic acid and acetylsalicylic acid in effervescent tablets.

The simultaneous spectrophotometric determination of ascorbic acid (AA) and acetylsalicylic acid (ASA) in effervescent tablets in the presence of the overlapping spectra was accomplished by the continuous wavelet transform (CWT), derivative spectrophotometry (DS) and partial least squares (PLS) approaches without using any chemical pre-treatment. CWT and DS calibration equations for AA and ASA were obtained by measuring the CWT and DS amplitudes corresponding to zero-crossing points of spectra obtained by plotting continuous wavelet coefficients and first-derivative absorbance values versus the wavelengths, respectively. The PLS calibration was constructed by using the concentration set and its full absorbance data consisting of 850 points from 220 to 305 nm in the range of 210-310 nm. These three methods were tested by analyzing the synthetic mixtures of the above drugs and they were applied to the real samples containing two commercial pharmaceutical preparations of subjected drugs. A comparative study was carried out by using the experimental results obtained from three analytical methodologies and precise and accurate results were obtained.

Ascorbic Acid↗

Comparison between UV Raman and circular dichroism detection of short alpha helices in bombolitin III.

We have used UV resonance Raman (UVRR) and circular dichroism (CD) spectroscopies to examine the dilute solution-phase secondary structure of the 17 amino acid peptide Bombolitin III (BIII). Both UVRR and CD clearly observe the alpha-helix structure induced by the addition of trifluoroethanol (TFE) to BIII. In contrast, only UVRR is able to detect the single alpha-helical turn induced by increasing the pH of BIII from pH 1.8 to 6.4. This alpha-helical turn is formed because of a stabilizing salt bridge formed between Lys(2) and Asp(5). Further increases in the alpha-helix content occur as the pH is raised further. We compare the relative sensitivity of UVRR and CD to short alpha helices and find, as expected, that the CD cannot detect short alpha helices. This study demonstrates that UV Raman measurements can detect the formation of single alpha-helical turns which cannot be detected by CD measurements.

Amino Acid Sequence↗

Linear regression analysis and its application to multivariate chromatographic calibration for the quantitative analysis of two-component mixtures.

Multivariate chromatographic calibration technique was developed for the quantitative analysis of binary mixtures enalapril maleate (EA) and hydrochlorothiazide (HCT) in tablets in the presence of losartan potassium (LST). The mathematical algorithm of multivariate chromatographic calibration technique is based on the use of the linear regression equations constructed using relationship between concentration and peak area at the five-wavelength set. The algorithm of this mathematical calibration model having a simple mathematical content was briefly described. This approach is a powerful mathematical tool for an optimum chromatographic multivariate calibration and elimination of fluctuations coming from instrumental and experimental conditions. This multivariate chromatographic calibration contains reduction of multivariate linear regression functions to univariate data set. The validation of model was carried out by analyzing various synthetic binary mixtures and using the standard addition technique. Developed calibration technique was applied to the analysis of the real pharmaceutical tablets containing EA and HCT. The obtained results were compared with those obtained by classical HPLC method. It was observed that the proposed multivariate chromatographic calibration gives better results than classical HPLC.

Calibration↗