PubMed Health⌕ Search

Biomedical subjects

Abdolkarim Abbaspour

Publications and source records attributed to Abdolkarim Abbaspour.

4 recordsLinked to original sources

Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead.

A Pt wire coated with a bentonite-carbon composite in a poly(vinyl chloride) membrane was used for detection of lead. The sensor has a Nernstian slope of 29.42+/-0.50 mV per decade over a wide range of concentration, 1.0 x 10(-7) to 1.0 x 10(-3) mol L(-1) Pb(NO(3))(2). The detection limit is 5.0 x 10(-8) mol L(-1) Pb(NO(3))(2) and the electrode is applicable in the pH range 3.0-6.7. It has a response time of approximately 10 s and can be used at least for three months. The electrode has good selectivity relative to nineteen other metal ions. The practical analytical utility of the electrode is demonstrated by measurement of Pb(II) in industrial waste and river water samples.

Bentonite↗

Electrocatalytic oxidation of guanine and DNA on a carbon paste electrode modified by cobalt hexacyanoferrate films.

The electrochemical behavior of cobalt hexacyanoferrate complex adsorbed on a carbon paste electrode (CPE) and its application to the electrocatalytic oxidation of guanine and single-strand DNA (ss-DNA) in aqueous solution are investigated in this report. The modification of CPE by the adsorption of this complex results in excellent amplification of the guanine oxidation response of ss-DNA. The effects of paste composition, scan rate, DNA, and guanine concentration were studied. The detection limits of 52 and 920 ng mL(-)(1) were obtained for guanine and ss-DNA, respectively.

Calibration↗

Simultaneous determination of zirconium and molybdenum by first-derivative spectrophotometry.

A first-derivative spectrophotometric method for the simultaneous determination of Zr and Mo with Alizarin Red S is described. Measurements were made at the zero-crossing wavelengths at 490.5 nm for Zr and 446.0 nm for Mo. The calibration graphs were linear at 0.5-20 and 0.5-13.0 microg ml(-1) for Zr and Mo, respectively. The possible interfering effects of various ions were studied. Only iron was interfered in this system. The validity of the method was examined by using some mixtures of Mo and Zr. The method was applied in different matrix in both presence and absence of some foreign metal ions.

Journal Article↗

Lead(II)-selective electrode based on phenyl disulfide.

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The proposed membrane sensor revealed high selectivity for Pb2+ over a wide variety of other metal ions and could be used in the pH range of 3.5-6.3. The electrode was used as an indicator electrode in potentiometric titration of lead ions.

Journal Article↗