PubMed Health⌕ Search

Biomedical subjects

Abdulaziz Boker

Publications and source records attributed to Abdulaziz Boker.

3 recordsLinked to original sources

Variable ventilation improves perioperative lung function in patients undergoing abdominal aortic aneurysmectomy.

BACKGROUND: Optimizing perioperative mechanical ventilation remains a significant clinical challenge. Experimental models indicate that "noisy" or variable ventilation (VV)--return of physiologic variability to respiratory rate and tidal volume--improves lung function compared with monotonous control mode ventilation (CV). VV was compared with CV in patients undergoing abdominal aortic aneurysmectomy, a patient group known to be at risk of deteriorating lung function perioperatively. METHODS: After baseline measurements under general anesthesia (CV with a tidal volume of 10 ml/kg and a respiratory rate of 10 breaths/min), patients were randomized to continue CV or switch to VV (computer control of the ventilator at the same minute ventilation but with 376 combinations of respiratory rate and tidal volume). Lung function was measured hourly for the next 6 h during surgery and recovery. RESULTS: Forty-one patients for aneurysmectomy were studied. The characteristics of the patients in the two groups were similar. Repeated-measures analysis of variance (group x time interaction) revealed greater arterial oxygen partial pressure (P = 0.011), lower arterial carbon dioxide partial pressure (P = 0.012), lower dead space ventilation (P = 0.011), increased compliance (P = 0.049), and lower mean peak inspiratory pressure (P = 0.013) with VV. CONCLUSIONS: The VV mode of ventilation significantly improved lung function over CV in patients undergoing abdominal aortic aneurysmectomy.

Aged↗

Improved arterial oxygenation with biologically variable or fractal ventilation using low tidal volumes in a porcine model of acute respiratory distress syndrome.

We compared biologically variable ventilation (V (bv); n = 9) with control mode ventilation (V (c); n = 8) at low tidal volume (VT)--initial 6 ml/kg--in a porcine model of acute respiratory distress syndrome (ARDS). Hemodynamics, respiratory gases, airway pressures, and VT data were measured. Static P-V curves were generated at 5 h. Interleukin (IL)-8 and IL-10 were measured in serum and tracheal aspirate. By 5 h, higher Pa(O(2)) (173 +/- 30 mm Hg versus 119 +/- 23 mm Hg; mean +/- SD; p < 0.0001 group x time interaction [G x T]), lower shunt fraction (6 +/- 1% versus 9 +/- 3%; p = 0.0026, G x T) at lower peak airway pressure (21 +/- 2 versus 24 +/- 1 cm H(2)O; p = 0.0342; G x T) occurred with V (bv). IL-8 concentrations in tracheal aspirate and wet:dry weight ratios were inversely related; p = 0.011. With V (c), IL-8 concentrations were 3.75-fold greater at wet:dry weight ratio of 10. IL-10 concentrations did not differ between groups. In both groups, ventilation was on the linear portion of the P-V curve. With V (bv), VT variability demonstrated an inverse power law indicating fractal behavior. In this model of ARDS, V (bv) improved Pa(O(2)) at lower peak airway pressure and IL-8 levels compared with V (c).

Analysis of Variance↗

The Amsterdam preoperative anxiety and information scale provides a simple and reliable measure of preoperative anxiety.

PURPOSE: To compare three anxiety scales; the anxiety visual analogue scale (VAS), the anxiety component of the Amsterdam preoperative anxiety and information scale (APAIS), and the state portion of the Spielburger state-trait anxiety inventory (STAI), for assessment of preoperative anxiety levels in same day admission patients. METHODS: Patients completed the three anxiety assessment scales both before and after seeing the anesthesiologist preoperatively. The scales used were the STAI, the six-question APAIS, and the VAS. APAIS was further subdivided to assess anxiety about anesthesia (sum A), anxiety about surgery (sum S) and a combined anxiety total (i.e., sum C = sum A + sum S). These scales were compared to one another. Pearson's correlation (pair-wise deletion) was used for validity testing. Cronbach's alpha analysis was used to test internal validity of the various components of the APAIS scale. A correlation co-efficient (r) > or = 0.6 and P < 0.05 were considered significant. RESULTS: Four hundred and sixty three scale sets were completed by 197 patients. There was significant and positive correlation between VAS and STAI r = 0.64, P < 0.001), VAS and APAIS r = 0.6, P < 0.001), sum C and STAI r = 0.63, P < 0.001) and between VAS and sum C r = 0.61, P < 0.001). Sum C and STAI r value were consistent with repeated administration. Cronbach's alpha-levels for the anxiety components of the APAIS (sum C) and desire for information were 0.84 and 0.77 respectively. CONCLUSION: In addition to VAS, the anxiety component of APAIS (sum C) is a promising new practical tool to assess preoperative patient anxiety levels.

Adult↗