Shape selectivity in the assembly of lithographically designed colloidal particles.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Abraham D Stroock.
Explore the source record for details and available documents.
Conventional wound dressings-gauze, plastic films, foams, and gels-do not allow for spatial and temporal control of the soluble chemistry within the wound bed, and are thus limited to a passive role in wound healing. Here, we present an active wound dressing (AWD) designed to control convective mass transfer with the wound bed; this mass transfer provides a means to tailor and monitor the chemical state of a wound and, potentially, to aid the healing process. We form this AWD as a bilayer of porous poly(hydroxyethyl methacrylate) (pHEMA) and silicone; the pHEMA acts as the interface with the wound bed, and a layer of silicone provides a vapor barrier and a support for connecting to external reservoirs and pumps. We measure the convective permeability of the pHEMA sponge, and use this value to design a device with a spatially uniform flow profile. We quantify the global coefficient of mass transfer of the AWD on a dissolvable synthetic surface, and compare it to existing theories of mass transfer in porous media. We also operate the AWD on model wound beds made of calcium alginate gel to demonstrate extraction and delivery of low molecular weight solutes and a model protein. Using this system, we demonstrate both uniform mass transfer over the entire wound bed and patterned mass transfer in three spatially distinct regions. Finally, we discuss opportunities and challenges for the clinical application of this design of an AWD.
Compaction of a nascent polypeptide chain inside the ribosomal exit tunnel, before it leaves the ribosome, has been proposed to accelerate the folding of newly synthesized proteins following their release from the ribosome. Thus, we used Kinetic Monte Carlo simulations of a minimalist on-lattice model to explore the effect that polypeptide translocation through a variety of channels has on protein folding kinetics. Our results demonstrate that tunnel confinement promotes faster folding of a well-designed protein relative to its folding in free space by displacing the unfolded state towards more compact structures that are closer to the transition state. Since the tunnel only forbids rarely visited, extended configurations, it has little effect on a "poorly designed" protein whose unfolded state is largely composed of low-energy, compact, misfolded configurations. The beneficial effect of the tunnel depends on its width; for example, a too-narrow tunnel enforces unfolded states with limited or no access to the transition state, while a too-wide tunnel has no effect on the unfolded state entropy. We speculate that such effects are likely to play an important role in the folding of some proteins or protein domains in the cellular environment and might dictate whether a protein folds co-translationally or post-translationally.
We report on the incorporation of microfluidic structure within a high-water-content hydrogel [4% (w/v) calcium alginate]. We used the microfluidic network to control the chemical environment within the hydrogel and demonstrated higher rates of delivery and extraction of solutes than was achievable by diffusion alone.
This report outlines a general method for the fabrication of immobilized gradients of biomolecules on surfaces. This method utilizes a microfluidic network that generates a gradient of avidin in solution and immobilizes this protein on the surface of glass or poly(dimethylsiloxane) by physical adsorption. The immobilized gradient of avidin is then translated into gradients of biotinylated ligands (e.g., small molecules, oligomers of DNA, polysaccharides) using the specific interaction between biotin and avidin. This method can also generate immobilized gradients of certain proteins and artificial polymers by a direct transfer of gradients from solution onto the surface. The major advantage of this method is that almost any type of molecule can, in principle, be immobilized in a well-defined surface gradient of arbitrary shape with dimensions of a few micrometers to a few centimeters. It is possible to tailor the precise shapes of gradients on surfaces from gradients in solution, either kinetically or competitively. Kinetic methods rely on controlling the time that the surface is exposed to the gradient in solution: when a single protein adsorbs from solution, the amount that adsorbs depends both on its concentration in solution and on the time allowed for adsorption. Competitive methods rely on exposure of the surface to a complementary gradient of two proteins in solution (In these experiments, the sum of the concentrations of the proteins in solution is independent of positions although the concentration of each, individually, depends on the position. In this procedure, the relative amount of each protein, at saturation on the surface, depends only on its concentration.).
Explore the source record for details and available documents.
An analytical model is presented for the three-dimensional flow in the recently introduced staggered herringbone mixer for microchannels. In this model, the flow in the cross-section of the channel is treated as a lid-driven cavity flow. The model is shown to reproduce the advection patterns that were observed experimentally in the staggered herringbone mixer. The model is then used to study the quality of mixing in this flow as a function of geometry. Analysis is performed with Poincaré maps, mixing simulations, and residence time distributions. A range of optimal geometries is identified.
This paper describes a microfluidic immunoassay that is applicable to the parallel determination of multiple analytes and that requires only a few microliters of sample. This assay relies on a microchannel network that achieves serial dilution of analytes; this network replaces manual dilutions employed in traditional immunoassays and enables the analysis of multiple analytes simultaneously. The immunoassay was demonstrated by an analysis of concentrations of antibodies against the HIV viral proteins gp120 and gp41 in human serum.
This Account reviews two procedures for controlling the flow of fluids in microchannels. The first procedure involves patterning the density of charge on the inner surfaces of a channel. These patterns generate recirculating electroosmotic flows in the presence of a steady electric field. The second procedure involves patterning topography on an inner surface of a channel. These patterns generate recirculation in the cross-section of steady, pressure-driven flows. This Account summarizes applications of these flow to mixing and to controlling dispersion (band broadening).
This paper describes the design and characterization of a small, membraneless redox fuel cell. The smallest channel dimensions of the cell were 2 mm x 50 mum or x 200 mum; the cell was fabricated in poly(dimethylsiloxane) using soft lithography. This all-vanadium fuel cell took advantage of laminar flow to obviate the need for a membrane to separate the solutions of oxidizing and reducing components.
Through a simple analytical description we quantify how pressure-driven flows over grooved surfaces develop transverse components, which, for shallow grooves, can be modeled with simple anisotropic effective boundary conditions. Helical recirculation results in channels or capillaries with grooved walls. An experimental validation of our model is presented. Our analysis provides a workable guide for the design of 3D flows with simple patterns of grooved regions, e.g., to control the position of streams in the cross section of a channel or to promote mixing. Potential applications in microfluidics are outlined.
A solid-object printer was used to produce masters for the fabrication of microfluidic devices in poly(dimethylsiloxane) (PDMS). The printer provides an alternative to photolithography for applications where features of > 250 microm are needed. Solid-object printing is capable of delivering objects that have dimensions as large as 250 x 190 x 200 mm (x, y, z) with feature sizes that can range from 10 cm to 250 microm. The user designs a device in 3-D in a CAD program, and the CAD file is used by the printer to fabricate a master directly without the need for a mask. The printer can produce complex structures, including multilevel features, in one unattended printing. The masters are robust and inexpensive and can be fabricated rapidly. Once a master was obtained, a PDMS replica was fabricated by molding against it and used to fabricate a microfluidic device. The capabilities of this method are demonstrated by fabricating devices that contain multilevel and tall features, devices that cover a large area (approximately 150 cm2), and devices that contain nonintersecting, crossing channels.
It is difficult to mix solutions in microchannels. Under typical operating conditions, flows in these channels are laminar-the spontaneous fluctuations of velocity that tend to homogenize fluids in turbulent flows are absent, and molecular diffusion across the channels is slow. We present a passive method for mixing streams of steady pressure-driven flows in microchannels at low Reynolds number. Using this method, the length of the channel required for mixing grows only logarithmically with the Péclet number, and hydrodynamic dispersion along the channel is reduced relative to that in a simple, smooth channel. This method uses bas-relief structures on the floor of the channel that are easily fabricated with commonly used methods of planar lithography.
This review describes the design and fabrication of microfluidic systems in poly(dimethylsiloxane) (PDMS). PDMS is a soft polymer with attractive physical and chemical properties: elasticity, optical transparency, flexible surface chemistry, low permeability to water, and low electrical conductivity. Soft lithography makes fabrication of microfluidic systems in PDMS particularly easy. Integration of components, and interfacing of devices with the user, is also convenient and simpler in PDMS than in systems made in hard materials. Fabrication of both single and multilayer microfluidic systems is straightforward in PDMS. Several components are described in detail: a passive chaotic mixer, pneumatically actuated switches and valves, a magnetic filter, functional membranes, and optical components.