PubMed Health⌕ Search

Biomedical subjects

Agustín Costa-García

Publications and source records attributed to Agustín Costa-García.

18 recordsLinked to original sources

Quantitative analysis of enzymatic assays using indoxyl-based substrates.

Hydrolysis of indoxyl-based substrates by hydrolytic enzymes is a commonly used semiquantitative detection system that generates a water-insoluble indigo dye which is difficult to quantify. This work describes the quantitative analysis and enzyme kinetics for alkaline phosphatase (AP) and 5-bromo-4-chloro-3-indoxyl phosphate (BCIP) in solution obtained by applying known solubilization methodology from the textiles industry to the enzymatic product. This proposal is based on the reduction of the tetrahalo-indigo blue dye in a basic medium with the aim of generating its aqueous-soluble parent compound termed indigo white, which gives a rich yellow color in solution and is fluorescent. A quantitative ELISA (where a soluble end product is required) is accomplished for first time using BCIP as substrate.

Alkaline Phosphatase↗

DNA single-base mismatch study with an electrochemical enzymatic genosensor.

A thorough selectivity study of DNA hybridization employing an electrochemical enzymatic genosensor is discussed here. After immobilizing on a gold film a 30-mer 3'-thiolated DNA strand, hybridization with a biotinylated complementary one takes place. Then, alkaline phosphatase is incorporated to the duplex through the interaction streptavidin-biotin. Enzymatic generation of indigo blue from 3-indoxyl phosphate and subsequent electrochemical detection was made. The influence of hybridization conditions was studied in order to better discern between fully complementary and mismatched strands. Detection of 3, 2 and 1 mismatch was possible. The type and location of the single-base mismatch, as well as the influence of the length of the strands was studied too. Mutations that suppose displacement of the reading frame were also considered. The effect of the concentration on the selectivity was tested, resulting a highly selective genosensor with an adequate sensitivity and stability.

Base Pair Mismatch↗

DNA hybridization sensor based on aurothiomalate electroactive label on glassy carbon electrodes.

In this work, a gold complex is used as electroactive label for monitoring hybridization assays on glassy carbon electrodes. Ionic gold is bound to a 30-mer sequence of the SARS (severe acute respiratory syndrome) virus, responsible for the atypical pneumonia, using sodium aurothiomalate. In order to label this single strand, a mixture of sodium aurothiomalate and the strand is prepared. Then, it is incubated for 24 h at 37 degrees C and, finally, free gold is separated from the labeled strand by a dialysis against a 0.15M NaCl solution (pH 7.5). The DNA hybridization sensor is designed immobilizing the complementary probe on the pre-treated electrode surface and, then, the hybridization reaction takes place with the gold labeled strand. The electrochemical determination is based on the catalytic effect of electrodeposited gold on the reduction of silver ions. In non-stringent experimental conditions, a limit of detection of 15 fmol (30 microL) is obtained, and discrimination between a complementary oligonucleotide and a three-based mismatch complementary oligonucleotide is achieved. For the discrimination of a single-base mismatch, is needed to use stringent conditions (50% of formamide in the hybridization buffer).

Biosensing Techniques↗

Flow screen-printed amperometric detection of p-nitrophenol in alkaline phosphatase-based assays.

p-Nitrophenyl phosphate is one of the most widely used substrates for alkaline phosphatase in ELISAs because its yellow, water-soluble product, p-nitrophenol, absorbs strongly at 405 nm. p-Nitrophenol is also electroactive; an oxidative peak at 0.97 V (vs. an Ag pseudoreference electrode) is obtained when a bare screen-printed carbon electrode is used. When an amperometric detector was coupled to a flow-injection analysis system the detection limit achieved for p-nitrophenol was 2x10(-8) mol L(-1), almost two orders of magnitude lower than that obtained by measuring the absorbance of the compound. By use of this electrochemical detection method, measurement of 7x10(-14) mol L(-1) alkaline phosphatase was achieved after incubation for 20 min. The feasibility of coupling immunoassay to screen-printed carbon electrode amperometric detection has been demonstrated by performing an ELISA for detection of pneumolysin, a toxin produced by Streptococcus pneumoniae, which causes respiratory infections. The method is simple, reproducible, and much more sensitive than traditional spectrophotometry.

Alkaline Phosphatase↗

Amperometric detector designs for capillary electrophoresis microchips.

Electrochemical (EC) detection is a sensitive and miniaturisable detection mode for capillary electrophoresis (CE) microchips. Detection cell design is very important in order to ensure electrical isolation from the high separation voltage. Amperometric detectors with different designs have been developed for coupling EC detection to CE-microchips. Different working electrode alignment: in-channel or end-channel has been tested in conjunction with several materials: gold, platinum or carbon. The end-channel detector was based on a platinum or gold wire manually aligned at the exit of the separation channel. Thick- (screen-printed carbon electrode) and thin-film (sputtered gold film) electrodes have also been employed with this configuration, but with a different design that allowed the rapid replacement of the electrode. The in-channel detector was based on a gold film within the separation channel. A gold-based dual electrode detector, which combined for the first time in- and end-channel detection, has been also tested. These amperometric detectors have been evaluated in combination to poly(methylmethacrylate) (PMMA) and Topas (thermoplastic olefin polymer of amorphous structure) CE-microchips. Topas is a new and promising cyclic olefin copolymer with high chemical resistance. Relevant parameters of the polymer microchip separation such as precision, efficiency or resolution and amperometric detection were studied with the different detector designs using p-aminophenol and L-ascorbic acid as model analytes in Tris-based buffer pH 9.0.

Carbon↗

Determination of human serum albumin using aurothiomalate as electroactive label.

A new electroactive label has been used to monitor immunoassays in the determination of human serum albumin (HSA) using glassy-carbon electrodes as supports for the immunological reactions. The label was a gold(I) complex, sodium aurothiomalate, which was bound to rabbit IgG anti-human serum albumin (anti-HSA-Au). The HSA was adsorbed on the electrode surface and the immunological reaction with gold-labelled anti-HSA was then performed for one hour by non-competitive or competitive procedures. The gold(I) bound to the anti-HSA was electrodeposited in 0.1 mol L-1 HCl at -1.00 V for 5 min then oxidised in 0.1 mol L-1 H2SO4 solution at +1.40 V for 1 min. Silver electrodeposition at -0.14 V for 1 min followed by anodic stripping voltammetry were then performed in aqueous 1.0 mol L-1 NH(3)-2.0x10(-4) mol L-1 AgNO3. For both non-competitive and competitive formats, calibration plots in the ranges 5.0x10(-10) to 1.0x10(-8) mol L-1 and 1.0x10(-10) to 1.0x10(-9) mol L-1 HSA, respectively, with estimated detection limits of 1.5x10(-10) mol L-1 (10 ng mL-1) and 1.0x10(-10) mol L-1 (7 ng mL-1), respectively, were obtained. Levels of HSA in two healthy volunteer urine samples were also evaluated, using both immunoassay formats.

Electrochemistry↗

Genosensor on gold films with enzymatic electrochemical detection of a SARS virus sequence.

A hybridisation-based genosensor was designed on a 100 nm sputtered gold film. This material worked as an immobilisation and transduction surface. A 30-mer sequence that encodes a short lysine-rich region, unique to SARS (severe acute respiratory syndrome) virus, was chosen as target. A complementary strand (probe), labelled with a thiol group at the 3'-end, was immobilised on the film. After blocking the surface, hybridisation with the biotin-conjugated SARS strand (at the 3'-end) took place. Interaction with alkaline phosphatase-labelled streptavidin permits amplified indirect electrochemical detection. The analytical signal is constituted by an electrochemical process of indigo carmine, the soluble product of the enzymatic hydrolysis of 3-indoxyl phosphate. The use of a sensitive electrochemical technique such as square wave voltammetry allowed a detection limit of 6 pM to be obtained for this DNA sequence, lower than any other found in the bibliography. The parameters affecting the methodology were studied, with special attention being placed on selectivity. Specificity was clearly enhanced when interaction time and stringency (in the form of formamide percentage) were increased. With 1h of strand interaction and employing 50% of formamide in the hybridisation buffer, a 3-base mismatch strand was perfectly distinguished from the complementary.

Biosensing Techniques↗

Amperometric PMMA-microchip with integrated gold working electrode for enzyme assays.

The use of a gold film in-channel detector combined with a poly(methyl methacrylate) (PMMA) CE microchip has been tested for alkaline phosphatase (AP) enzymatic assays. Tris-borate or Tris-Gly (pH 9.0, 50 mmol L(-1)) buffer solutions were appropriate as running buffer. Signals for three common AP products: alpha-naphthol, p-nitrophenol, and ascorbic acid, were obtained. They were reproducible (RSD 4.4% for six successive electropherograms corresponding to 5 mmol L(-1) alpha-naphthol solution) and the response was dependent on concentration (linear relationship for ascorbic acid solutions between 5 and 20 mmol L(-1) concentration). Use of an end-channel gold film electrode was also investigated. If one of the reagents (substrate or enzyme) is included in the running buffer, two different types of enzymatic assay are feasible in less than 3 min.

Electrodes↗

Amperometric detection in TMB/HRP-based assays.

3,3',5,5'-Tetramethylbenzidine (TMB) is the most commonly used chromogen for horseradish peroxidase (HRP) and so its performance as an electrochemical substrate was evaluated. Measurements of HRP activity in solution were carried out by using an amperometric detector coupled to a flow injection analysis (FIA) system. The enzymatic product was easily detected at a potential of +0.1 V (vs. Ag-pseudoreference electrode) at a bare screen-printed electrode placed in a homemade electrochemical flow cell. A high flow rate (4.3 mL min(-1)) of 0.5 M H2SO4 was used to obtain repeatable signals and a short analysis time. The detection limit achieved after 15 min of incubation was 2x10(-14) M of HRP. The applicability of the amperometric detector to ELISAs was demonstrated by using a commercially available kit for the quantification of interleukin-6 (IL-6) without modifying the kit manufacturer's protocol or the reagents for this test.

Benzidines↗

Genosensor based on a platinum(II) complex as electrocatalytic label.

Voltammetric genosensors on streptavidin-modified screen-printed carbon electrodes (SPCEs) for the detection of virulence nucleic acid determinants of pneumolysin (ply) and autolysin (lytA) genes, exclusively present on the genome of the human pathogen Streptococcus pneumoniae, were described. The oligonucleotide probes were immobilized on electrochemically pretreated SPCEs through the streptavidin/biotin reaction. After that, the hybridization reaction was carried out with labeled complementary targets on the electrode surface. The ply and lytA targets were labeled using the universal linkage system, which consists of the use of a platinum(II) complex that acts as coupling agent between targets and a, usually fluorescent, molecule label. In this case, the platinum(II) complex acts as a label itself because the analytical signal is achieved by measuring chronoamperometrically the current generated by the hydrogen evolution catalyzed by platinum. In nonstringent experimental conditions, these genosensors can detect 24.5 fmol of 20-mer oligonucleotide target and discriminate between a complementary oligo and an oligo with a three-base mismatch. In presence of 25% formamide in the hybridization buffer, a single-base mismatch on the oligonucleotide target can be detected.

Bacterial Proteins↗

Immunosensor for Mycobacterium tuberculosis on screen-printed carbon electrodes.

In this work, two methods have been compared to produce enzymatic voltammetric immunosensors for the determination of Mycobacterium tuberculosis antigens (Ag360 and Ag231), using a pre-oxidised screen-printed carbon electrode (SPCE) as a signal transduction element. The enzyme alkaline phosphatase (AP) was used in combination with the substrate 3-indoxyl phosphate (3-IP). In one design, the immune complexes between M. tuberculosis antigens and monoclonal antibodies against M. tuberculosis were formed out of the electrode surface. Then, the immune complexes were captured by biotinylated rabbit anti-M. tuberculosis antibodies, immobilised on the streptavidin modified SPCEs through the streptavidin:biotin reaction. Finally, an alkaline phosphatase (AP) labelled rabbit IgG anti-mouse immunoglobulin G was used as a detector antibody. In the other design, the M. tuberculosis antigens were captured by monoclonal antibodies against M. tuberculosis, which were immobilised on the electrode surface through the reaction with rabbit IgG passively adsorbed on the SPCEs. The biotinylated rabbit anti-M. tuberculosis antibodies were used with an alkaline phosphatase labelled streptavidin as detector antibodies. The best results for M. tuberculosis antigen determination were obtained using the immunosensor on the streptavidin modified SPCEs and the immune complexes between antigen Ag231 and monoclonal antibodies MabF184-3, with a detection limit of 1.0 ng/ml. The immunosensor was also applied to Ag231 spiked proteic matrices.

Alkaline Phosphatase↗

Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection.

A capillary electrophoresis (CE) microchip made of a new and promising polymeric material: Topas (thermoplastic olefin polymer of amorphous structure), a cyclic olefin copolymer with high chemical resistance, has been tested for the first time with analytical purposes, employing an electrochemical detection. A simple end-channel platinum amperometric detector has been designed, checked, and optimized in a poly-(methylmethacrylate) (PMMA) CE microchip. The end-channel design is based on a platinum wire manually aligned at the exit of the separation channel. This is a simple and durable detection in which the working electrode is not pretreated. H(2)O(2) was employed as model analyte to study the performance of the PMMA microchip and the detector. Factors influencing migration and detection processes were examined and optimized. Separation of H(2)O(2) and L-ascorbic acid (AsA) was developed in order to evaluate the efficiency of microchips using different buffer systems. This detection has been checked for the first time with a microchip made of Topas, obtaining a good linear relationship for mixtures of H(2)O(2) and AsA in different buffers.

Ascorbic Acid↗

Enzymatic genosensor on streptavidin-modified screen-printed carbon electrodes.

Voltammetric enzyme genosensors on streptavidin-modified screen-printed carbon electrodes (SPCEs) for the detection of virulence nucleic acid determinants of pneumolysin and autolysin genes, exclusively present on the genome of the human pathogen Streptococcus pneumoniae, were described. Alkaline phosphatase (AP) and 3-indoxyl phosphate were used as the enzymatic label and substrate, respectively. The oligonucleotide probes were immobilized on electrochemically pretreated SPCEs through the streptavidin/biotin reaction. The adsorption of streptavidin was performed by deposition of a drop of a streptavidin solution overnight at 4 degrees C on the surface of the SPCEs. After the hybridization reaction with FITC-labeled complementary targets, the enzyme is captured using an anti-FITC antibody conjugated to AP. In nonstringent experimental conditions, these genosensors can detect 0.49 fmol of 20-mer oligonucleotide target and discriminate between a complementary oligo and an oligo with a three-base mismatch. In the presence of 25% formamide in the hybridization buffer, a single-base mismatch on the oligonucleotide target can be detected.

Adsorption↗

Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements.

The detection of human immunoglobulin M (IgM) was performed using capacitively coupled contactless conductivity detection (CCD) in electrophoresis carried out in conventional capillaries as well as on glass and poly(meth-yl methacrylate) (PMMA) microdevices. Also achieved was the analyses of IgG (an anti-human IgM) and the complex formed in the reaction between the two immunoreagents. It is demonstrated that CCD is a powerful tool suitable not only for the detection of antibodies but also for monitoring an immunological interaction. Conductivity measurements allow the direct determination of immunoreagents, and it is advantageous, since no labels are required. The immunoglobulin IgM has been taken as model analyte. The reproducibility of the analytical signal (RSD = 1%), sensitivity and limits of detection obtained for IgM (0.15 ng/mL in conventional capillaries and 34 ng/mL in microchips) are comparable to those previously obtained with amperometric detection. The immunological reaction was performed either in conventional microtiter plates as used in ELISA or in situ on the glass chip.

Electric Conductivity↗

The use of gold bands for flow immunoelectrochemical devices.

Gold bands sputtered over a polymeric material, Kapton, have been employed not only for electrochemical detection but also for the development of enzyme immunoassays in a flow system. The immunological interactions on bands acting as reactors are considered for a model analyte, IgM. Different formats of flow immunoassays, competitive and non-competitive, have been checked. Compared with previous results, automation gives rise to in a reduction in analysis time and in reagent consumption. Lower limits of detection are also obtained. Detection, which is also carried out in the flow system, is based on the oxidation of naphthol, the product of the enzymatic hydrolysis of naphthyl-phosphate.

Electrochemistry↗

Voltammetric and flow amperometric methods for the determination of melatonin in pharmaceuticals.

Melatonin can be sensitively detected in pharmaceuticals by two different and simple electrochemical methods: cyclic voltammetry (CV) and amperometric detection in a flow injection analysis system (FIA-ED). An adequate pre-treatment of the carbon paste electrode in the first case and the employ of a high flow rate in the second one were the key for obtaining a very good reproducibility (R.S.D. values of 1.5 (n=10) and 1.3% (n=20), respectively). Low limits of detection were achieved and with the coupling of a flow system a linear dynamic range of three orders of magnitude (from 10(-8) to 10(-5) M) was obtained. Both methods were applied to the determination of melatonin in pharmaceuticals. In order to best validate these methodologies a fluorescent procedure was developed to contrast the results. As no interferences from the matrix were found the employ of a separation technique is not necessary. In this way the procedure is fastened and simplified. Moreover, the low price, ease of handling, possibility of automation and high sample throughput are important advantages that convert the flow methodology in an attractive alternative for quality control of pharmaceuticals.

Antioxidants↗

Gold bands as a suitable surface for enzyme immunoassays.

Gold bands sputtered over a polymeric material, Kapton, are employed for the development of enzyme immunoassays. The immunological interaction takes place between human IgM and alkaline phosphatase (AP) conjugated anti-IgM. The model analyte (IgM) could be determined following a non-competitive design in the range of 0.05-5 ppm, with a limit of detection of 50 ppb. After the interaction, gold bands are sequentially inserted in a flow system and the extension of the reaction is followed through the enzymatic hydrolysis of naphthylphosphate, AP substrate. The product, naphthol, is oxidised to naphtoquinone in the gold band of the flow cell that constitutes the detector. Parameters affecting the interaction are studied and calibration curves are performed. The reproducibility between different bands (RSD=4%, n=5) and possibilities of regeneration are also detailed.

Adsorption↗

Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system.

Amperometric analysis of indigo carmine at a bare screen-printed electrode placed in an FIA system is reported. This compound is easily detected at a potential of -0.3 V (vs. Ag pseudo-reference electrode) without observing any fouling of the electrode surface, thus allowing the repetitive use of the same electrode in a reproducible manner (coefficients of variation down to 7% for more than 20 consecutive determinations). A linear range of three orders of magnitude and a limit of detection in the sub-micromolar range were attained for this molecule. Based on these studies, indirect amperometric measurements of alkaline phosphatase (ALP) activity in solution were easily carried out using 3-indoxyl phosphate substrate. Its hydrolysis catalyzed by ALP gave rise to indigo product. This product is insoluble in aqueous solutions but it was easily converted into its soluble parent compound, indigo carmine, by addition of fuming sulfuric acid to the reaction media. Using this approach, we achieved a linear range of more than one order of magnitude and a limit of detection of 1 U/l ALP, for an enzymatic reaction time of 60 min.

Alkaline Phosphatase↗