Determination of fluoroquinolones in milk samples by postcolumn derivatization liquid chromatography with luminescence detection.

A liquid chromatography (LC) method with luminescence detection for the determination of eight quinolone antibiotics is reported. The system encompasses three consecutive steps: (a) chromatographic separation using reverse-phase mode (RP-LC), (b) postcolumn derivatization reaction, and (c) luminescence detection by monitoring fluorescence (FL) and time-resolved (TR) signals. The derivatization step is based on the reaction between quinolones and terbium(III) to form luminescent chelates, which were determined at lambda(ex) 340 and lambda(em) 545 nm (FL mode) or at lambda(ex) 281 and lambda(em) 545 nm (TR mode). Dynamic ranges of the calibration graphs, obtained with standard solutions of analytes and FL and TR modes, respectively, were 190-3500 and 316-2000 ng mL-1 for marbofloxacin, 8-3500 and 8.1-1500 ng mL-1 for ciprofloxacin, 6.2-3500 and 13-1500 ng mL-1 for danofloxacin, 7.4-3500 and 8.4-1500 ng mL-1 for enrofloxacin, 14-3500 and 20-2000 ng mL-1 for sarafloxacin, 12.5-3500 and 13.9-1200 ng mL-1 for difloxacin, 7.6-3500 and 13-3000 ng mL-1 for oxolinic acid, and 9-2000 and 130-3000 ng mL-1 for flumequine. Limit of detection values obtained using FL and TR modes, respectively, were 60 and 95 ng mL-1 for marbofloxacin, 2 and 2.4 ng mL-1 for ciprofloxacin, 1.9 and 3.9 ng mL-1 for danofloxacin, 2.2 and 2.5 ng mL-1 for enrofloxacin, 3.8 and 7 ng mL-1 for sarafloxacin, 4 and 4.2 ng mL-1 for difloxacin, 2.3 and 4 ng mL-1 for oxolinic acid, and 2.7 and 40 ng mL-1 for flumequine. The precision was established at two concentration levels of each analyte and expressed as the percentage of relative standard deviation with values ranging between 1.9 and 7.8%. The validation procedure for the analysis of samples was carried out using European Community recommendations, and the decision limit and detection capability were calculated for bovine whole milk. The method was applied to whole, semiskimmed, and skimmed milk samples spiked with the target analytes, and the recoveries ranged between 93.3 and 106.0%.

Animals↗

Usefulness of ytterbium(III) as analytical reagent for total sulfite determination in white wine samples.

Ytterbium(III) is used as reagent for the determination of sulfite by measuring the formation of the Yb(III)-sulfite complex through the variation of the light scattering intensity with time. The low solubility of this complex causes an efficient dispersion of the radiation at 490 nm, which is measured at 980 nm. Each kinetic datum is automatically obtained in only 0.5 s by stopped-flow mixing technique. The application of the initial rate method using a long emission wavelength minimizes the potential interference of fluorescent background signals from the sample matrix. The dynamic range of the calibration graph is 1-250 microg/mL, and the calculated detection limit is 0.35 microg/mL. The precision, expressed as relative standard deviation, is <6%. The method has been applied to the determination of total sulfites in white wine samples, which requires only the sample dilution and the use of two aliquots to improve selectivity. However, the matrix effect found for red wines precludes the application of the method to the direct analysis of these samples. Analytical recoveries ranged from 96.0 to 106.7%. The results obtained with the proposed method agreed with those provided by the p-rosaniline method. Unlike this method, in which toxic reagents are required, the use of ytterbium(III) as analytical reagent shows the advantage of its low acute toxic rating.

Hydrogen-Ion Concentration↗

Stopped-flow fluorescence polarization immunoassay.

A general survey of the analytical application of kinetic methodology in fluorescence polarization immunoassay (FPIA) is presented. Stopped-flow mixing technique (SF) allows the initial rate of the immunochemical reaction between the tracer and the antibody to be obtained, which is used as the analytical parameter instead of the equilibrium signal used in conventional FPIA. The instrumentation required is described and the features of the analytical methods proposed are compared with those obtained by conventional FPIA. The usefulness of SF-FPIA for routine screening in clinical, environmental and food analysis is discussed.

Fluorescence Polarization Immunoassay↗