High-energy phase-contrast X-ray imaging using a two-crystal X-ray interferometer.

To broaden the scope of phase-contrast X-ray imaging in biomedical applications, the energy of X-rays in a large-area imaging system using a two-crystal X-ray interferometer has been increased from 17.7 keV to 35 keV. The use of higher-energy X-rays makes it possible to observe larger samples having greater variation in density within shorter measurement periods, at higher spatial resolution, and at lower X-ray doses. After optimizing the imaging system for 35 keV X-rays, a 25 mm x 30 mm interference pattern with 50% visibility was generated at the Photon Factory. The system's capabilities are demonstrated by this pattern and a high-quality three-dimensional image of a rat heart.

Animals↗

Coherence-contrast x-ray imaging based on x-ray interferometry.

Coherence-contrast x-ray imaging--which detects changes in the degree of coherence caused by the placement of a sample in an x-ray interferometer--was developed for biomedical applications. Because the technique's sensitivity depends on the density gradient in the sample, it is particularly suitable for observing biomedical samples with large density differences, such as samples that include both biological soft tissue and bone. A measurement principle and method of this technique are described, and a fine coherence-contrast image of a mouse leg is given as an example result.

Animals↗

Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer.

Large-area (25 x 20 mm) phase-contrast X-ray imaging was attained by using a skew-symmetric two-crystal X-ray interferometer. The sub-nrad angular control required to operate the X-ray interferometer was achieved with a sleeve bearing and a feedback-positioning system. As a demonstration, measurements of a phase map of a rat's liver and a phase-contrast tomographic three-dimensional image of a piece of a rabbit's liver were performed at the Photon Factory using 0.07 nm synchrotron radiation X-rays.

Animals↗

Vessel imaging by interferometric phase-contrast X-ray technique.

BACKGROUND: Phase-contrast x-ray imaging using an x-ray interferometer has great potential to reveal the structures inside soft tissues, because the sensitivity of this method to hydrogen, carbon, nitrogen, and oxygen is approximately 1000 times higher than that of the absorption-contrast x-ray method. Imaging of vessels is very important to understand the vascular distribution of organs and tumors, so the possibility of selective angiography based on phase contrast is examined with a physiological material composed of low-atomic-number elements. METHODS AND RESULTS: Phase-contrast x-ray imaging was performed with a synchrotron x-ray source. Differences in refractive index, ddelta, of physiological saline, lactated Ringer's solution, 5% glucose, artificial blood such as pyridoxylated hemoglobin-polyoxyethylene conjugate, and perfluorotributylamine were measured. Because the ddelta of physiological saline has highest contrast, it was used for the phase-contrast x-ray imaging of vessel, and this was compared with absorption-contrast x-ray images. Vessels >0.03 mm in diameter of excised liver from rats and a rabbit were revealed clearly in phase-contrast x-ray imaging, whereas the vessel could not be revealed at all by the absorption-contrast x-ray image. Absorption-contrast x-ray images with iodine microspheres depicted only portal veins >0.1 mm in diameter with nearly the same x-ray dose as the present phase-contrast x-ray imaging. CONCLUSIONS: Phase-contrast x-ray imaging explored clear depiction of the vessels using physiological saline with small doses of x-rays.

Angiography↗

[Phase-contrast x-ray imaging with x-ray interferometer for medical applications].

Phase-contrast x-ray imaging with x-ray interferometer can depict the minute difference within the biological object, and its sensitivity is about 1000 times higher than that of absorption-contrast method. For biomedical use of this technique, a large monolithic x-ray interferometer and 2 crystal interferometer having a field of view with 25 mm x 25 mm is being developed. Phase-contrast x-ray CT could reveal detail structures within tumor and surrounded tissue, and the vessel imaging of rat liver is also possible using physiological saline at 17.7 keV x-ray energy. Recently, human breast tissues were imaged at 35 keV and the contrast of image was much better than usual absorption contrast x-ray image obtained at 17.7 keV energy.

Animals↗