PubMed Health⌕ Search

Biomedical subjects

Akram Aldroubi

Publications and source records attributed to Akram Aldroubi.

3 recordsLinked to original sources

Improved fiber tractography with Bayesian tensor regularization.

Diffusion tensor tractography suffers from the effects of noise and partial volume averaging (PVA). For reliable reconstruction of fiber pathways, tracking algorithms that are robust to these artifacts are called for. To meet this need, the present study establishes a novel Bayesian regularization framework for fiber tracking that takes into account the effects of noise and PVA, thereby improving tracking accuracy and precision. With this framework, the propagation of a fiber path follows an optimal vector determined by Bayes decision rule; the probability functions involved are modeled on the basis of multivariate normal distributions of diffusion tensor elements, which allows the optimal solution with maximum a posteriori probability to be derived analytically. Parameters for the probability functions are estimated from the uncertainty of tensor elements and the variance among tensors within an oriented sampling volume weighted by fractional anisotropy. Experiments with Monte Carlo simulations, synthetic, and in vivo human diffusion tensor data demonstrate that this specialized scheme enhances the immunity of fiber tracking to noise and PVA, and hence enables fibers to be more faithfully reconstructed.

Adult↗

The adaptive bases algorithm for intensity-based nonrigid image registration.

Nonrigid registration of medical images is important for a number of applications such as the creation of population averages, atlas-based segmentation, or geometric correction of functional magnetic resonance imaging (fMRI) images to name a few. In recent years, a number of methods have been proposed to solve this problem, one class of which involves maximizing a mutual information (MI)-based objective function over a regular grid of splines. This approach has produced good results but its computational complexity is proportional to the compliance of the transformation required to register the smallest structures in the image. Here, we propose a method that permits the spatial adaptation of the transformation's compliance. This spatial adaptation allows us to reduce the number of degrees of freedom in the overall transformation, thus speeding up the process and improving its convergence properties. To develop this method, we introduce several novelties: 1) we rely on radially symmetric basis functions rather than B-splines traditionally used to model the deformation field; 2) we propose a metric to identify regions that are poorly registered and over which the transformation needs to be improved; 3) we partition the global registration problem into several smaller ones; and 4) we introduce a new constraint scheme that allows us to produce transformations that are topologically correct. We compare the approach we propose to more traditional ones and show that our new algorithm compares favorably to those in current use.

Algorithms↗

A continuous tensor field approximation of discrete DT-MRI data for extracting microstructural and architectural features of tissue.

The effective diffusion tensor of water, D, measured by diffusion tensor MRI (DT-MRI), is inherently a discrete, noisy, voxel-averaged sample of an underlying macroscopic effective diffusion tensor field, D(x). Within fibrous tissues this field is presumed to be continuous and smooth at a gross anatomical length scale. Here a new, general mathematical framework is proposed that uses measured DT-MRI data to produce a continuous approximation to D(x). One essential finding is that the continuous tensor field representation can be constructed by repeatedly performing one-dimensional B-spline transforms of the DT-MRI data. The fidelity and noise-immunity of this approximation are tested using a set of synthetically generated tensor fields to which background noise is added via Monte Carlo methods. Generally, these tensor field templates are reproduced faithfully except at boundaries where diffusion properties change discontinuously or where the tensor field is not microscopically homogeneous. Away from such regions, the tensor field approximation does not introduce bias in useful DT-MRI parameters, such as Trace(D(x)). It also facilitates the calculation of several new parameters, particularly differential quantities obtained from the tensor of spatial gradients of D(x). As an example, we show that they can identify tissue boundaries across which diffusion properties change rapidly using in vivo human brain data. One important application of this methodology is to improve the reliability and robustness of DT-MRI fiber tractography.

Anisotropy↗