PubMed Health⌕ Search

Biomedical subjects

Alain Berthod

Publications and source records attributed to Alain Berthod.

16 recordsLinked to original sources

Solvent systems for countercurrent chromatography: an aqueous two phase liquid system based on a room temperature ionic liquid.

A new aqueous two phase liquid system (ATPS) based on the ionic liquid 1-butyl-3-methyl imidazolium chloride (BMIM Cl), potassium dibasic phosphate (K(2)HPO(4)) and water was recently proposed in the literature. The full phase diagram of this ATPS was prepared and some tie lines were fully determined. It was compared to classical ATPSs based on polyethylene glycol with an average molecular mass of 1000 (PEG 1000) and 10,000 (PEG 10000) and K(2)HPO(4). Two countercurrent chromatography (CCC) columns, a hydrostatic Sanki and a J type hydrodynamic CCC columns were used to test the liquid phase retention of these ATPSs in all possible configurations. It was found that the BMIM Cl ATPS liquid phases were much easier to retain in the two CCC columns than the PEG 1000 ATPS phases. Using protein and alcohol solutes, it was established that the BMIM Cl ATPS has a polarity completely different from that of the PEG 1000 ATPS. For example, ovalbumin partitions equally between the two phases of the PEG 1000 ATPS (K(D)=1.4) when it is completely located in the BMIM Cl upper phase of the ionic liquid ATPS (K(D)=180). The discrimination factor of the ionic liquid system and its intrinsic hydrophobicity were respectively found three times higher and ten times lower than the respective values of the PEG 1000 ATPS.

Countercurrent Distribution↗

Band broadening inside the chromatographic column: the interest of a liquid stationary phase.

Band broadening inside chromatographic columns was studied by Giddings 40 years ago. This theory is revisited pointing out that the band width depends only on the band position, x, inside the column and the height equivalent to a theoretical plate, H, and not on the solute affinity for the stationary phase. The band standard deviation, sigma, inside the column is simply sigma = square root [xH]. This property can be used in countercurrent chromatography (CCC), a chromatographic technique that works with a liquid stationary phase. Two possibilities are presented: 1-extrusion of the liquid stationary phase called elution-extrusion method, and 2-slow motion of the stationary phase in the same direction as the mobile phase, called cocurrent CCC method. A mixture of five steroids, prednisone, prednisolone acetate, testosterone, estrone and cholesterol, with partition coefficient varying from 0.1 to 40, is used with a 53 mL CCC column to show the method capabilities. The elution-extrusion method is discontinuous; however, it allows saving dramatic amounts of solvent and time. Cholesterol could be fully resolved in 2h and 120 mL instead of 7 h and 1.2 L using the classical elution way. The cocurrent CCC method is continuous and was able to resolve cholesterol at baseline in 40 min using 110 mL. Detection is difficult due to the fact that two immiscible liquid phases enter the detector.

Acetates↗

Using the liquid nature of the stationary phase in countercurrent chromatography. IV. The cocurrent CCC method.

The retention volumes of solutes in countercurrent chromatography (CCC) are directly proportional to their distribution coefficients, K(D) in the biphasic liquid system used as mobile and stationary phase in the CCC column. The cocurrent CCC method consists in putting the liquid "stationary" phase in slow motion in the same direction as the mobile phase. A mixture of five steroid compounds of widely differing polarities was used as a test mixture to evaluate the capabilities of the method with the biphasic liquid system made of water/methanol/ethyl acetate/heptane 6/5/6/5 (v/v) and a 53 mL CCC column of the coil planet centrifuge type. It is shown that the chromatographic resolution obtained in cocurrent CCC is very good because the solute band broadening is minimized as long as the solute is located inside the "stationary" phase. Pushing the method at its limits, it is demonstrated that the five steroids can still be (partly) separated when the flow rate of the two liquid phases is the same (2 mL/min). This is due to the higher volume of upper phase (72% of the column volume) contained inside the CCC column producing a lower linear speed compared to the aqueous lower phase linear speed. The capabilities of the cocurrent CCC method compare well with those of the gradient elution method in HPLC. Continuous detection is a problem due to the fact that two immiscible liquid phases elute from the column. It was partly solved using an evaporative light scattering detector.

Chromatography, High Pressure Liquid↗

Reversed phase liquid chromatography of alkyl-imidazolium ionic liquids.

Eleven 1-alkyl-3-methyl imidazolium ionic liquid (IL) salts were analyzed in reversed phase mode with a Kromasil C18 column. The mobile phases were water-rich acetonitrile solutions (water content > or =70%, v/v) without any added salts. It is shown that it is possible to separate different ILs sharing the same cation and differing by the anion when salt-free mobile phases are used. When a buffer, acetate or phosphate salt, or any salt, such as sodium chloride or sodium tetrafluorobarate, is added to the mobile phase, the ILs differing only by their anions cannot be separated. ILs with different alkyl chains in the imidazolium cation are separated by mobile phases with or without added salts following a hydrophobic interaction behavior: log k is proportional to nC, the carbon number of the alkyl chain. Important differences in ion/stationary phase interactions are observed depending on the ionic content of the mobile phase. With salt-free mobile phases, the IL/C18 stationary phase interactions correspond to concave isotherms associated with fronting peaks for all ILs. With mobile phase containing 0.01 M of salt, tailing IL peaks correspond to convex adsorption isotherms. Also, the IL retention factor depends on the concentration and nature of the added salt. Hexafluorophosphate chaotropic anions can adsorb on the Kromasil C18 surface dramatically increasing the imidazolium cation retention factors.

Chromatography, Liquid↗

Theory and use of the pseudophase model in gas-liquid chromatographic enantiomeric separations.

The theory and use of the "three-phase" model in enantioselective gas-liquid chromatography utilizing a methylated cyclodextrin/polysiloxane stationary phase is presented for the first time. Equations are derived that account for all three partition equilibria in the system, including partitioning between the gas mobile phase and both stationary-phase components and the analyte equilibrium between the polysiloxane and cyclodextrin pseudophase. The separation of the retention contributions from the achiral and chiral parts of the stationary phase can be easily accomplished. Also, it allows the direct examination of the two contributions to enantioselctivity, i.e., that which occurs completely in the liquid stationary phase versus the direct transfer of the chiral analyte in the gas phase to the dissolved chiral selector. Six compounds were studied to verify the model: 1-phenylethanol, alpha-ionone, 3-methyl-1-indanone, o-(chloromethyl)phenyl sulfoxide, o-(bromomethyl)phenyl sulfoxide, and ethyl p-tolylsulfonate. Generally, the cyclodextrin component of the stationary phase contributes to retention more than the bulk liquid polysiloxane. This may be an important requirement for effective GC chiral stationary phases. In addition, the roles of enthalpy and entropy toward enantiorecognition by this stationary phase were examined. While enantiomeric differences in both enthalpy and entropy provide chiral discrimination, the contribution of entropy appears to be more significant in this regard. The three-phase model may be applied to any gas-liquid chromatography stationary phase involving a pseudophase.

Arylsulfonates↗

Nonmolecular solvents in separation methods: dual nature of room temperature ionic liquids.

Room temperature ionic liquids (RTIL) are molten salts starting to be used as nonmolecular solvents in separation methods mainly for their extremely low vapor pressure and thermal stability. RTILs are formed by an anion associated to a cation. This intrinsic structure gives them a dual nature. When used as additives in RPLC mobile phases to enhance basic compound separation, RTILs lose their particular physicochemical properties to become just salts. However, a given RTIL is not equivalent to another one made with the same cation. It is shown that both the anion and the cation contribute to solute retention and peak efficiency extending beyond simple "salting-out" or ion-pairing effects. Nine different alkyl-methyl-imidazolium ionic liquids with different alkyl chain length and chloride or BF(4-) or PF(6-) anions were used as additives (50 mM max. conc.) in the liquid chromatography separation of some cationic basic solutes on a Kromasil C18 column. It is shown with sodium salts and an acetonitrile-water 30/70 v/v mobile phase that anions can adsorb on the stationary phase surface according to their lyotropic character. They can also form ion pairs with the cationic basic solutes. Alkyl-imidazolium cations also adsorb on the C18 bonded stationary phase due to hydrophobic character depending on their alkyl chain length. Anion adsorption dramatically increases the cationic solute retention factors when cation adsorption decreases them. The cation adsorption is mainly responsible for peak shape and efficiency enhancements. RTILs are additives that enhance the basic cationic solute peak shape changing peak position. A wise choice of the appropriate combination of anion lyotropy with imidazolium cation hydrophobicity allows playing with solute selectivity and analysis duration.

Journal Article↗

Uptake and enantioselective elimination of chlordane compounds by common carp (Cyprinus carpio, L.).

An analytical method involving supercritical fluid extraction (SFE) followed by a two-dimensional gas chromatography (2D-GC) analysis was developed to determine the concentration (first GC) and enantiomeric ratio (second GC) of cis- and trans-chlordanes at the ppb (ng/g) level in fish tissue. The SFE method allowed concentration of the compounds of interest, and reduced the number of extraction and sample clean-up manipulations as compared to classical solvent extraction techniques. Four hundred common carp fingerling (Cyprinus carpio, L.) were exposed for three days to water containing 5 ppb (5 ng/g) technical grade chlordane containing about 1 ppb of chlordane isomers. The fish concentrated the pesticides more than 200 times (162 and 312 ng/g of cis- and trans-chlordane, respectively). However, the uptake is not enantioselective. The concentration of the principle constituents and their enantiomeric ratio was followed during a fifty days growth period in chlordane free water. The first order decay of concentration was observed with a half time of about 18 days for both the cis- and trans-chlordane isomers. However it was found that the enantiomeric ratio of the trans-chlordane was significantly altered during this short period of time, decreasing from ER=1 to ER=0.7, while no enantiomeric changes were observed for the cis-chlordane. It seems that the (-)-trans-chlordane is metabolized significantly faster (t(1/2-)=15 days) in the river carp fish than the (+)-trans-enantiomer (t(1/2+)=20 days).

Animals↗

Temperature and enantioseparation by macrocyclic glycopeptide chiral stationary phases.

Seventy-one chiral compounds were separated on four macrocyclic glycopeptide chiral selectors: teicoplanin, its aglycone, ristocetin A and vancomycin, using three possible separation modes: reversed phase with methanol/buffer mobile phases, normal phase with hexane/ethanol mobile phases and polar ionic mode (PIM) with 100% methanol mobile phase with trace amounts of acid and/or base. These 148 separations were studied in a 5-45 degrees C temperature range. Peak efficiencies always increased with temperature, but in only 17% of the separations studied a small increase of the enantioresolution factor was observed. In the majority (83%) of the cases, the enantioresolution decreased or even vanished when temperature increased. All 148 Van't Hoff plots were linear showing that the selector did not change in the temperature range studied. The calculated enthalpy and entropy variations showed that the interaction of the solute with the stationary phase was always enthalpy driven with normal and reversed mobile phases. It could be enthalpy as well as entropy driven with PIM mobile phases strongly dependent on the solute. The plots of delta(deltaH) versus delta(deltaS) were linear in most cases (enthalpy entropy compensation). This observation cannot be used to give clear information on chiral recognition mechanisms, but it allowed identifying specific stationary phase-solute interactions because the points corresponding to the respective thermodynamic parameters were clearly delineated from the general compensation lines.

Glycopeptides↗

Countercurrent chromatographic isolation of lolitrem B from endophyte-infected ryegrass (Lolium perenne L.) seed.

This paper describes a new method of purification of the Lolitrem B, a tremorgenic mycotoxin produced in planta by the endophytic fungus Neotyphodium lolii. The method is based on the large-scale isolation of the toxin by countercurrent chromatography (CCC). The lolitrem B content in endophyted ryegrass seed, 11 microg/g or 11 ppm, is extracted by stirring finely ground seeds with ethanol for 3 h at room temperature. The concentrated crude extract contains about 0.6 mg/g or 600 ppm of lolitrem B. It is then submitted to CCC purification with a biphasic four-solvent liquid system. A 160-fold enrichment was obtained in one step producing a raffinate containing 10% or 100 mg/g of the toxin. Further purifications were then performed by thin layer and low pressure liquid chromatography. Twenty-eight micrograms of lolitrem B with a 96% purity grade were obtained from 8 kg of seeds (yield 32%).

Chromatography, High Pressure Liquid↗

Elution-extrusion countercurrent chromatography. Use of the liquid nature of the stationary phase to extend the hydrophobicity window.

Countercurrent chromatography (CCC) is a liquid chromatography technique with a liquid stationary phase. Taking advantage of the liquid nature of the stationary phase, it is possible to perform unique operations not possible in classical liquid chromatography with a solid stationary phase. It is easy to avoid any solute-irreversible absorption in the CCC column. If the retention volumes of solutes become too high, the dual mode will be used. The roles of the phases are reversed. The stationary phase becomes the mobile phase, and the CCC column is started again. The solutes elute rapidly in what was previously the stationary phase. The theoretical basis of the dual-mode method is recalled. The dual-mode method is a discontinuous method. The separation should be stopped when the phase switch is performed. The elution-extrusion procedure is another way to avoid any irreversible adsorption of solutes in the column. The method uses the fact that the liquid volumes occupied by the solutes highly retained inside the column can be orders of magnitude lower than the mobile-phase volume that would be needed to elute them. The elution-extrusion method also has two steps: the first step is a regular CCC chromatogram. Next, the stationary phase containing the partially separated hydrophobic solutes is extruded out of the column in a continuous way using the liquid stationary phase. The theory of the process is developed and compared to the dual-mode theory. Alkylbenzene homologues are experimentally used as model compounds with the heptane/methanol/water biphasic liquid system to establish the theoretical treatment and compare the performance of two types, hydrodynamic and hydrostatic, of CCC columns. It is shown that the method can dramatically boost the separation power of the CCC technique. An apparent efficiency higher than 20 000 plates was obtained for extruded octylbenzene and a 160-mL hydrodynamic CCC column with less than 500 plates when conventionally used.

Journal Article↗

Ionic matrices for matrix-assisted laser desorption/ionization time-of-flight detection of DNA oligomers.

Salts with low melting points, also termed room-temperature ionic liquids, can be used as matrices in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF). They have great vacuum stability, and can dissolve polar and apolar solutes including carbohydrates, biological oligomers and proteins. The ionic liquids give much more homogeneous sample solutions compared with solid matrices. We demonstrate the usefulness of using ionic matrices to determine the molecular weight of DNA oligomers by direct TOF mass spectrometric analysis. Three oligonucleotides were tested, (d(pT)(10), d(pC)(11), and d(pC)(12)), with several ionic matrices synthesized from different bases associated to two acids (3-hydroxypicolinic acid and 2,5-dihydroxybenzoic acid). The results obtained show that the best ionic matrices enhance the ion peak intensity of the oligonucleotides with respect to conventional molecular matrices under our experimental conditions. In one case, an ionic matrix provided a signal-to-noise ratio ten times higher than the corresponding molecular matrix. Several of the tested ionic matrices were liquids. However, all working ionic matrices were solids.

DNA↗

Super/subcritical fluid chromatography chiral separations with macrocyclic glycopeptide stationary phases.

The chiral recognition capabilities of three macrocyclic glycopeptide chiral selectors, namely teicoplanin (Chirobiotic T), its aglycone (Chirobiotic TAG) and ristocetin (Chirobiotic R), were evaluated with supercritical and subcritical fluid mobile phases. A set of 111 chiral compounds including heterocycles, analgesics (nonsteroidal antiinflamatory compounds), beta-blockers, sulfoxides, N-protected amino acids and native amino acids was separated on the three chiral stationary phases (CSPs). All separations were done with an outlet pressure regulated at 100 bar, 31 degrees C and at 4 ml/min. Various amounts of methanol ranging from 7 to 67% (v/v) were added to the carbon dioxide along with small amounts (0.1 to 0.5%, v/v) of triethylamine and/or trifluoroacetic acid. The Chirobiotic TAG CSP was the most effective closely followed by the Chirobiotic T column. Both columns were able to separate, partially or fully, 92% of the enantiomers of the compound set. The ristocetin chiral selector could partially or baseline resolve only 60% of the enantiomers tested. All separations were done in less than 15 min and 70% were done in less than 4 min. The speed of the separations is the main advantage of the use of SFC compared to normal-phase HPLC. In addition, SFC is advantageous for preparative separations with easy solute recovery and solvent disposal.

Chromatography, Liquid↗

Separation of chiral sulfoxides by liquid chromatography using macrocyclic glycopeptide chiral stationary phases.

A set of 42 chiral compounds containing stereogenic sulfur was prepared. There were 31 chiral sulfoxide compounds, three tosylated sulfilimines and eight sulfinate esters. The separations were done using five different macrocyclic glycopeptide chiral stationary phases (CSPs), namely ristocetin A, teicoplanin, teicoplanin aglycone (TAG), vancomycin and vancomycin aglycone (VAG) and seven eluents, three normal-phase mobile phases, two reversed phases and two polar organic mobile phases. Altogether the macrocyclic glycopeptide CSPs were able to separate the whole set of the 34 sulfoxide enantiomers and tosylated derivatives. Five of the eight sulfinate esters were also separated. The teicoplanin and TAG CSPs were the most effective CSPs able to resolve 35 and 33 of the 42 compounds. The three other CSPs each were able to resolve more than 27 compounds. The normal-phase mode was the most effective followed by the reversed-phase mode with methanol-water mobile phases. Few of these compounds could be separated in the polar organic mode with 100% methanol mobile phases. Acetonitrile was also not a good solvent for the resolution of enantiomers of sulfur-containing compounds, neither in the reversed-phase nor in the polar organic mode. The structure of the chiral molecules was compared to the enantioselectivity factors obtained with the teicoplanin and TAG CSP. It is shown that the polarity, volume and shape of the sulfoxide substituents influence the solute enantioselectivity factor. Changing the oxidation state of the sulfur atom from sulfoxides to sulfinate esters is detrimental to the compound's enantioselectivity. The enantiomeric retention order on the teicoplanin and TAG CSPs was very consistent: the (S)-(+)-sulfoxide enantiomer was always the less retained enantiomer. In contrast, the (R)-(-)-enantiomer was less retained by the ristocetin A, vancomycin and vancomycin aglycone columns, showing the complementarity of these CSPs. The macrocyclic glycopeptide CSPs provided broad selectivity and effective separations of chiral sulfoxides.

Chromatography, Liquid↗

Chiral separation of basic drugs by capillary electrophoresis with carboxymethylcyclodextrins.

Capillary electrophoresis (CE) with carboxymethylated beta- or gamma-cyclodextrins was used to achieve the rapid enantiomeric separation of a set of basic drugs. The enantiomers of 12 chiral amino-containing pharmaceutical compounds belonging to various therapeutic categories were analyzed by CE using an uncoated 60 cm x 75 microm I.D. silica capillary. Several experimental parameters such as the nature, concentration and pH of the buffer, nature and concentration of the anionic cyclodextrin and temperature were studied in order to optimize the enantiomeric separation. The variation of the solute partition coefficient for the chiral selector, the enantioselectivity and resolution factors are used to assess the quality of the chiral separation. It is shown that the solute affinity for the chiral selector is not related to its enantioresolution factor. None of the two cyclodextrin selectors used was able to separate the whole set of basic drugs.

Borates↗

Evaluation of molecule-microbe interactions with capillary electrophoresis: procedures, utility and restrictions.

Understanding the interactions between molecules and living organisms is of paramount importance for the evaluation of pharmaceutical activity, chemical toxicity and all manner of microbiological studies. The capability of capillary electrophoresis (CE) in the evaluation of molecule-microbe interactions is examined in the present paper. The fundamental chemical concept of the binding or association constant for molecular systems measured in free solution is discussed for biological systems where microorganisms uptake or associate with molecules from their environment. The heterogeneity of the living organisms must be understood and accounted for including differences related to semantics such as concentration units and the nature of the associations between two entities and large differences in the size and number of microorganisms as compared to molecules. Finally, the added complexity and even inhomogeneity of a cell compared to most molecular systems must be considered and possibly controlled. The binding of specific molecules to viruses is discussed. CE can be utilized to quickly determine if a molecule binds very strongly or not at all to a cell (i.e., a binary yes/no answer). This could be useful for initial high-throughput screening purposes when using capillary arrays, for example. CE can be useful for determining unusual (large) molecule/microbe stoichiometries. Finally, CE can sometimes be used to determine the size of binding constants (K(RL)) within certain limits provided experimental conditions can be formulated that minimize problems of biological heterogeneity.

Bacterial Physiological Phenomena↗