PubMed Health⌕ Search

Biomedical subjects

Alain Uziel

Publications and source records attributed to Alain Uziel.

8 recordsLinked to original sources

Early maturation of evoked otoacoustic emissions and medial olivocochlear reflex in preterm neonates.

The present study was designed to investigate the early maturation of the brainstem regulation of the cochlear function in preterm neonates. Evoked otoacoustic emissions (EOAE) and their regulation via the medial olivocochlear efferent (MOC) reflex were investigated in a large population of preterm neonates and compared with full-term neonates and young babies from birth to 4 y and school-aged children. In 28-wk preterm neonates, EOAE were seen in the mid-frequency range. These responses extended both to the low (down to 1025 Hz) and high (up to 6152 Hz) frequency ranges at 38 wk of gestational age and remained stable up to 4 mo. At this stage, the amplitude of EOAE overlapped adult values. EOAE amplitudes then decreased to reach adult values at 3 y of age. Maturation of MOC efferents innervating the outer hair cells was investigated by studying the suppressive effect of contralateral sound on the EOAE amplitudes (MOC reflex). The first MOC responses were recorded in preterm neonates of 32-33 wk of gestational age, reaching adult-like values at 37 wk of gestational age. The maximum effect of MOC efferent activation occurred between 2000 and 4000 Hz. These results suggest that, in humans, MOC efferents mature in utero. Thus, testing the MOC reflex may have a clinical relevance to detect an abnormal development of the auditory pathways, particularly of a brainstem circuitry not explored through conventional testing.

Child, Preschool↗

Characteristics of tinnitus in a population of 555 patients: specificities of tinnitus induced by noise trauma.

Tinnitus is often associated with hearing loss of a known etiology. In this study, we compared tinnitus that appeared to be induced by noise trauma with that perceived to start in other circumstances in a population of 555 patients attending the specialist tinnitus clinic at the University Hospital in Montpellier, France. Patients had consulted for persistent tinnitus for 7 years from the onset of their symptoms. Among these tinnitus patients, 17% described their tinnitus as starting after excessive noise exposure. The patients who had a history of noise trauma had a symmetrical hearing loss, and no difference was seen in lateralization of tinnitus perception. This subset of patients was mainly male and on average was 10 years younger than other tinnitus patients. In this population, the hearing loss is significantly less than that measured in the other patients, even allowing for their younger age. Statistical analysis showed a significant correlation between a history of exposure to noise trauma and the presence of a high-pitched "whistling" tinnitus. The presence of whistling tinnitus was significantly correlated with high-frequency hearing loss. The intensity of tinnitus, measured using a visual analog scale, appeared to be stronger than the measured hearing loss would suggest.

Adolescent↗

Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting.

OBJECTIVE: In cochlear implant recipients, the threshold of the electrically evoked compound action potential (ECAP) has been shown to correlate with the perceptual detection threshold and maximum comfortable loudness levels (respectively, T- and C-levels) used for implant programming. Our general objective was to model the relationship between ECAP threshold and T/C-levels by taking into account their relative changes within each subject. In particular, we were interested in investigating further the validity of ECAP threshold as a predictor of psychophysical levels, depending on intra-cochlear electrode location and time of testing (from 1 to 18 months post-implantation). METHODS: A total of 370 ECAP thresholds, measured in 49 children, using a Nucleus 24 cochlear implant, were compared with the corresponding T- and C-levels obtained at the same visit, for the same electrode. Response profiles for the whole group of patients were modeled across four test electrodes spaced equally along the electrode array from base towards apex. A linear regression model was constructed and the quality of the ECAP threshold-based predictions was assessed by testing for correlation between measured and predicted psychophysics. Comparison was made with a more simplistic model (described here as the 'parallel profiles method') stipulating, within each subject, a 1 microA increase in psychophysical levels for every 1 microA increase in ECAP threshold. RESULTS: Offset between ECAP threshold and psychophysics profiles was found to vary significantly along the electrode array for the T-, but not for the C-level. In contrast with the parallel profiles method, our regression model predicted, within each subject, an average increase of 0.23 microA (95% confidence interval: 0.18-0.28) in T-level for every 1 microA increase in ECAP threshold. This correction improved the quality of T-level prediction when our model was run using measured T-level and ECAP threshold from a reference electrode (r=0.77 vs. r=0.62). The shorter the distance between the electrode for which T-level was predicted and the one used as reference, the stronger the correlation between measured and predicted T-levels. In addition, poorer T-level predictions were obtained at the basal end of the array during the first 3 months post-implantation. In contrast to T-level, individual changes in C-level with ECAP threshold exhibited heterogeneous patterns across subjects so that no common coefficient could account for these changes. However, applying the parallel profiles method led to high-quality C-level prediction. CONCLUSIONS AND SIGNIFICANCE: The results suggest that covariation between ECAP thresholds and psychophysics plays a decisive role in the relationship of ECAP threshold with T-, but not with C-level. Therefore, our regression model and the parallel profiles method should both be used for predicting, respectively, the T- and the C-levels. Although the predictability of our regression model seems to be better for middle and apical electrodes, its utilization should be extended to basal electrodes after 6 months' implant use.

Action Potentials↗

A middle ear implant, the Symphonix Vibrant Soundbridge: retrospective study of the first 125 patients implanted in France.

OBJECTIVE: The Vibrant Soundbridge is an active semi-implantable middle ear implant for the rehabilitation of patients with a sensorineural hearing loss who are not able to derive adequate benefit from conventional hearing aids. A retrospective study was performed to assess the overall level of satisfaction of implanted patients and to investigate the potential determinants of postoperative success. STUDY DESIGN: A retrospective survey of audiological data from repeated measures and subjective data from self-assessment scales administered postoperatively was conducted to determine the degree of benefit and satisfaction for Vibrant Soundbridge implantees. SETTING: Twenty-one tertiary referral and teaching hospitals. SUBJECTS: The first 125 VSB implantees implanted in France between August 1997 and May 2001 were included in the study. RESULTS: No clinically significant change was observed for residual hearing postoperatively. Most patients (83%) reported they were either satisfied or very satisfied with the Vibrant Soundbridge. Analysis of correlation revealed a moderate correlation (Pearson coefficient r = 0.59) between the degree of benefit reported via the patient survey and the degree of benefit reported via the Glasgow Benefit Inventory. A moderate correlation (Pearson coefficient r = 0.66) was observed between speech comprehension scores in quiet for the preoperative unaided condition and the postoperative aided Vibrant Soundbridge condition. No correlation was observed between subjective reports of satisfaction postoperatively and performance on preoperative objective tests or patient characteristics. CONCLUSION: The results indicate a high level of satisfaction with the VSB as a treatment of sensorineural hearing impairment in patients with a wide range of characteristics. Preoperative scores for unaided speech comprehension tests in quiet may be a potential indicator of success on aided Vibrant Soundbridge speech comprehension tests postoperatively but do not reflect patient satisfaction with the device reported on self-assessment scales.

Adult↗

Rehabilitation for high-frequency sensorineural hearing impairment in adults with the symphonix vibrant soundbridge: a comparative study.

OBJECTIVE: To assess and compare the benefits for patients with high-frequency hearing loss obtained from an implantable middle ear implant, the Symphonix Vibrant Soundbridge using the SIGNIA processing circuitry, to those derived from conventional amplification using the same integrated circuitry and to those derived from a variety of preoperatively worn hearing aids. STUDY DESIGN: A single-subject, repeated-measures study design was used for a comparative evaluation of the benefits derived from the Symphonix Vibrant Soundbridge and conventional amplification. Objective audiometric measures were performed postoperatively to compare the Symphonix Vibrant Soundbridge (404) and SIGNIA hearing aid, both using the SIGNIA processing chip. Tests were performed under three conditions: unaided, aided Symphonix Vibrant Soundbridge (404), and aided SIGNIA hearing aid. Subjective self-assessment scales, standardized and nonstandardized, were completed for the Symphonix Vibrant Soundbridge (404) and the preoperative hearing aid to compare the personally perceived benefits. Statistical comparison of the data sets with each device type was performed using the nonparametric Wilcoxon test. SETTING: One tertiary teaching hospital and one hearing aid specialist fitting office. SUBJECTS: Six patients displaying a high-frequency hearing loss who had the Symphonix Vibrant Soundbridge implanted for an average of 17 months. INTERVENTION: Rehabilitative. RESULTS: Aided thresholds with the Symphonix Vibrant Soundbridge (404) and the SIGNIA hearing aid showed no significant difference. Speech comprehension scores in quiet and in noise were significantly improved with each device type over the unaided condition scores. Individual performance on speech test measures was equivalent or superior with the Symphonix Vibrant Soundbridge (404) in comparison with that with the SIGNIA hearing aid. When using the Symphonix Vibrant Soundbridge (404) in quiet, the group achieved 50% speech comprehension at significantly softer presentation levels (p = 0.027) than when wearing the SIGNIA hearing aid. Similarly, in noise, 50% speech comprehension was achieved at significantly lower (more difficult) signal-to-noise ratios (p = 0.028) with the Symphonix Vibrant Soundbridge (404) than with the SIGNIA hearing aid. The level of satisfaction for various aspects of the device and performance and listening ease, particularly in the presence of aversive sounds and in reverberant conditions, was reported as significantly better with the Symphonix Vibrant Soundbridge (404) than with the preoperative hearing aid. CONCLUSIONS: Despite similar gain with each device type using the same SIGNIA processing technology, the patient group demonstrated significant advantages for speech comprehension in quiet and in noise when using the Symphonix Vibrant Soundbridge (404). Such an effect may be attributed to higher fidelity sound transmission by means of the direct-drive mechanism used by the implant. Subjective reports support the results from the objective assessments, both being in favor of the implant over conventional amplification. In conclusion, the Symphonix Vibrant Soundbridge (404) is a suitable treatment option offering advantages over conventional amplification to the hearing-impaired person with a high-frequency hearing loss.

Adult↗

Cochlear implantation in prelingually deafened children with residual hearing.

OBJECTIVE: The purpose of this study was to examine the speech perception skills of prelingually deafened French children with preoperative residual hearing who received multichannel cochlear implants. DESIGN: The design of the study incorporated a within-subject, repeated measures design for assessing speech perception skills. SETTING: Montpellier, Toulouse and Lyon Pediatric Cochlear Implant Centers. SUBJECTS: Seven prelingually deafened children demonstrating marginal benefit from conventional amplification prior to implantation with a Nucleus multichannel cochlear implant, served as subjects for the speech perception assessment (a speech recognition score less than 30% defines marginal benefit from acoustic amplification on open set materials). The mean age at implantation was 7 years, 9 months. OUTCOME MEASURES: Speech perception skills were assessed using open set materials and the MUSS and MAIS questionnaires. RESULTS: Open-set speech recognition averaged 21.4% before implantation, and 83.6% after 1 year's cochlear implant experience. All children demonstrated an open-set score over 60% after 12 months of CI use. MAIS test scores averaged 18.1/40 before implantation and 35.1/40 after 9 months of CI use. MUSS test scores averaged 24.4/40 before implantation and 34.1/40 after 9 months of CI use. CONCLUSIONS: Cochlear implantation should be considered for prelingually hearing impaired children demonstrating marginal benefit from hearing aids, with a speech recognition score less than 30% on open set materials, in order to improve their speech discrimination skills.

Audiometry↗

Contralateral sound stimulation suppresses the compound action potential from the auditory nerve in humans.

BACKGROUND: In the past decade, contralateral sound suppression of otoacoustic emissions has been extensively used to study the role of the medial olivocochlear efferent in humans. In most studies, the suppressive effect of contralateral sound stimulation was not greater than 2 to 4 dB. However, the relation between the degree of otoacoustic emission reduction and the neural auditory threshold is unknown. METHODS: The current study investigates the effect of contralateral sound stimulation by measuring compound action potential response from the auditory nerve during retrosigmoid surgery in humans. RESULTS: Although only a small number of subjects responded to contralateral sound stimulation, we report that efferent activation by contralateral sound stimulation results in 10 dB effective neural attenuation. CONCLUSIONS: Together with previous otoacoustic emission measurements in humans, this result demonstrates that the suppressive effect of contralateral noise suppression is greater when measured with compound action potential than otoacoustic emissions, and that contralateral sound suppressive effect is at least as strong in humans as in animals.

Acoustic Stimulation↗

Characteristics of tinnitus and etiology of associated hearing loss: a study of 123 patients.

The aim of this study was to highlight the clinical characteristics of tinnitus and to attempt a quantitative assessment in relation to any underlying etiologies. We undertook to study a population of 123 patients attending a tinnitus clinic between 1998 and 2000. Their answers on a questionnaire allowed detailed evaluation of the characteristics of tinnitus, including such variables as the circumstances in which the tinnitus was first noticed and evaluation of its intensity and frequency. The patients each underwent a full neurootological examination with the aim of diagnosing an etiology. The great majority of tinnitus patients had an endocochlear deafness and, among these patients, acoustic trauma, endolymphatic hydrops, and presbyacusis were the commonest diagnoses (32%, 32%, and 23%, respectively). Of these patients, 93.7% with noise trauma an 86.9% with presbyacusis described their tinnitus as a stable, high-pitched whistling. Those patients with active Ménière's disease or Ménière's-like syndrome described a low-pitched buzzing tinnitus. Analysis of those patients with a stable high-pitched tinnitus associated with a high-frequency hearing loss shows a statistically significant correlation between the elevation of the audiometric thresholds and the loudness of the tinnitus. For a large majority of patients with tinnitus, therefore, audiometry provides an indirect test for evaluating the tinnitus.

Adolescent↗