PubMed Health⌕ Search

Biomedical subjects

Alan Kadish

Publications and source records attributed to Alan Kadish.

23 records · Page 2Linked to original sources

Characterization of fibrillatory rhythms by ensemble vector directional analysis.

Recent studies have demonstrated that fibrillatory rhythms are not random phenomena but have definable patterns. However, standard mapping techniques may have limitations in their ability to identify the organization of fibrillation. The purpose of this study was to develop and apply a method, "ensemble vector mapping," for characterizing the spatiotemporal organization of fibrillation. Ventricular fibrillation was induced by burst pacing in normal mongrel dogs. In a separate protocol, atrial fibrillation was induced by epicardial aconitine application. Epicardial electrograms were recorded from a 112-electrode plaque array using a computerized mapping system. Vectors were created by summing orthogonal bipolar electrograms. The magnitude of the vectors was transformed using a logarithmic function, integrated over time, and normalized for local electrogram amplitude to produce an "ensemble vector" index whose magnitude is high when beat-to-beat activation direction is consistent and low when activation direction is variable. The mean index was 137 +/- 36 mV/s during ventricular pacing at a cycle length of 300 ms but only 39 +/- 23 mV/s during ventricular fibrillation (P < 0.001). The ensemble vector index was also lower during atrial fibrillation (60 +/- 54 mV/s) than during atrial pacing (115 +/- 27 mV/s, P < 0.01 vs. atrial fibrillation) but not as low as during ventricular fibrillation (P < 0.05, atrial vs. ventricular fibrillation). The index was also capable of distinguishing atrial tachycardia from atrial fibrillation. Ensemble vector mapping produces an objective assessment of the consistency of myocardial activation during fibrillation. The consistency of activation direction differs in different models of fibrillation and is higher during atrial than ventricular fibrillation. This technique has the potential to rapidly characterize repetitive activation patterns in fibrillatory rhythms and may help distinguish among different characteristics of fibrillatory rhythms.

Animals↗

Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation.

Ventricular fibrillation is the main mechanism of sudden cardiac death, but the source of its spontaneous initiation has not been mapped. 16 patients were investigated by electrography and radiofrequency ablation after resuscitation from recurrent idiopathic ventricular fibrillation. Triggers of ventricular fibrillation originated from various locations within the Purkinje system in 12 patients and from the ordinary myocardial muscle in four. The accuracy of mapping was confirmed by acute elimination of triggers by radiofrequency delivery, and there was no recurrence of ventricular fibrillation in 14 patients. Long-term follow-up is necessary to establish that ablation is curative and avoids use of a defibrillator.

Adolescent↗

Gender differences in arrhythmias.

Electrocardiographic and electrophysiologic differences between men and women have long been noted. Women have a higher intrinsic heart rate than men, along with a longer corrected QT interval and a shorter sinus nodal recovery time. The incidence of and risk factors for a variety of arrhythmias differ between men and women. Atrioventricular nodal reentry tachycardia has a 2:1 female-to-male predominance, while accessory pathways are twice as frequent in men. Although atrial fibrillation is more prevalent in men of all age groups, the absolute numbers of men and women with atrial fibrillation are equal, and the associated morbidity and mortality experienced by women with atrial fibrillation appear to be worse. Women have a lower incidence of sudden cardiac death, and female survivors of sudden cardiac death have a lower frequency of spontaneous or inducible ventricular tachycardia. On the other hand, drug-induced torsade de pointes and symptomatic long QT syndrome have a female predominance. Therefore, greater caution should be used when prescribing QT-prolonging drugs in women. The incidence of arrhythmias is increased during pregnancy, and management of pregnant patients poses a significant challenge. The mechanisms of these gender differences are unclear but may be related to hormonal effects and the shorter QT interval in adult males. Pharmacologic and nonpharmacologic therapies are usually equally efficacious, but the risks of pharmacologic therapy are different in men and women. Atrial fibrillation may be more difficult to treat in women.

Arrhythmias, Cardiac↗

In vitro performance characteristics of reused ablation catheters.

BACKGROUND: Prior studies have found that there is a widespread practice of catheter reprocessing in cardiac electrophysiology laboratories. Effects of reprocessing of ablation catheters on temperature sensing and mechanical deflection are not fully known. METHODS: Twenty-four new and used ablation catheters were studied. Deviation of temperature sensing by catheters from the temperature of a heated saline bath was measured. The angle of deflection of digitally scanned catheters at 75% and 100% handle deflection was also measured. New and used catheters were compared with respect to their temperature sensing accuracy and deflection characteristics. RESULTS: Overall, there was 0.7 +/- 0.1 degrees C (mean +/- standard error) deviation of the sensed temperature from the bath temperature, with no significant difference between new and used catheters. Similarly, there was no significant difference in the angle of deflection between new (66.7 degrees +/- 6.2 degrees and 24.3 degrees +/- 6.8 degrees at 75% and 100% deflections, respectively) and used (59.6 degrees +/- 5.6 degrees and 28.7 degrees +/- 9.9 degrees at 75% and 100% deflections, respectively) catheters. The difference in the angle of deflection between matched new and used catheters was 18.9 degrees +/- 4.2 degrees and 10.9 degrees +/- 2.4 degrees at 75% and 100% deflections, respectively, with a relatively broad range (5.0 degrees -35.6 degrees and 0.4 degrees -19.0 degrees at 75% and 100% deflections, respectively). CONCLUSIONS: This study found no significant overall difference in temperature sensing accuracy and deflection angle of new and used ablation catheters. Nevertheless, individual differences in deflection characteristics between new and used catheters are occasionally seen and warrant screening of reprocessed catheters prior to their reuse.

Catheter Ablation↗