PubMed Health⌕ Search

Biomedical subjects

Alan M Wilson

Publications and source records attributed to Alan M Wilson.

11 recordsLinked to original sources

Gait characterisation and classification in horses.

Although a large number of foot-fall sequences are possible in quadrupeds, few sequences are routinely used. The aim of this paper is to characterise, by foot-fall pattern, the gaits used by horses and develop a novel technique to classify symmetric and asymmetric gaits using one common criterion. To achieve this speed and relative foot-fall, timings of all four limbs of eight Icelandic horses were measured using accelerometers. Linear discriminant analysis (LDA) was performed to find criteria that are optimal for discriminating between the different gaits. This also allowed us to evaluate whether gaits should be considered a continuum or as discrete entities. Foot-fall timings (stance times, swing times, duty factors and stride frequencies) for walk, tolt, trot, pace, left canter, right canter, left gallop and right gallop during over-ground locomotion at a range of speeds are presented. In the gaits of walk, tolt, trot and pace, foot-fall timings were equal between left and right hindlimbs and forelimbs so these gaits can be considered as symmetrical. Differences in stance times and duty factors were observed between gaits but are unlikely to be of biological significance due to their similar magnitude and inconsistent relative trends. This implies that metabolics or peak limb forces derived from contact times are unlikely to be the principal driving factors in gait transition between walk, trot, pace, canters and gallops, although these factors may influence the use of tolt at the lower and higher speeds. Gaits did cluster in the LDA space and the running gaits (tolt, trot, pace, left and right canters and gallops) could be considered a kinematic continuum but the relative relationship with walk may be more complex. Thus, LDA analysis has enabled common criteria to be discovered to accurately classify equine gaits on the basis of foot-fall timings on a stride-by-stride basis.

Animals↗

Accounting for elite indoor 200 m sprint results.

Times for indoor 200 m sprint races are notably worse than those for outdoor races. In addition, there is a considerable bias against competitors drawn in inside lanes (with smaller bend radii). Centripetal acceleration requirements increase average forces during sprinting around bends. These increased forces can be modulated by changes in duty factor (the proportion of stride the limb is in contact with the ground). If duty factor is increased to keep limb forces constant, and protraction time and distance travelled during stance are unchanging, bend-running speeds are reduced. Here, we use results from the 2004 Olympics and World Indoor Championships to show quantitatively that the decreased performances in indoor competition, and the bias by lane number, are consistent with this 'constant limb force' hypothesis. Even elite athletes appear constrained by limb forces.

Humans↗

A comparison of three-dimensional ultrasound, two-dimensional ultrasound and dissections for determination of lesion volume in tendons.

The purpose of this work was to evaluate the accuracy and precision of a freehand three-dimensional (3-D) ultrasonography system in the determination of lesion volume in tendons. The accuracy and precision of a 3-D ultrasonography system was assessed by performing repeated measurements on a phantom of known volume. Volume measurements of tendon lesions performed with 3-D ultrasonography were compared with measurements based on a series of two-dimensional (2-D) ultrasound (US) scans and to direct measurements from dissections. A novel method for the creation of tendon lesions in vitro was developed. 3-D US showed excellent precision and accuracy in measurements of the phantom (mean measured volume = 3.76 mL, calculated volume = 3.77 mL, coefficient of variation (CoV) = 0.54%) and good repeatability in the determination of tendon lesions (repeatability coefficient = 0.00047). All three methods examined were repeatable (repeatability coefficient for 2-D US = 0.00032, repeatability coefficient for dissections = 0.00076). However, each of the methods produced different results and no constant relationship could be found between any of the measurement methods. Both 3-D and 2-D US proved to be repeatable techniques for the measurement of the volume of a tendon lesion. Even if they produced different results, each of them can be repeatedly used individually. It was not possible to define which one provided the most accurate value as a result of difficulties encountered in lesion identification on histology, and therefore the lack of a gold standard.

Animals↗

Mechanical evaluation of two crimp clamp systems for extracapsular stabilization of the cranial cruciate ligament-deficient canine stifle.

OBJECTIVE: To compare the mechanical properties and interoperator variabilities of 2 crimp clamp systems for extracapsular, fabello-tibial, nylon loop stabilization of the cranial cruciate ligament-deficient stifle in dogs. STUDY DESIGN: In vitro mechanical testing. METHODS: Three operators with different grip strengths each secured 20 standardized nylon loops using stainless-steel crimp clamps: 10 using a Veterinary Instrumentation system (45 kg [100 lb] test nylon leader line, 12 mm crimp clamps) and 10 using a Securos system (36 kg [80 lb] test nylon leader line, 36 kg [80 lb] crimp clamps). Loops were tensile loaded to failure in a materials testing machine. RESULTS: Mean ultimate load and mean stiffness were significantly higher for the Securos (336.9 N, 60.6 N/mm) than for the Veterinary Instrumentation system (113.8 N, 37.0 N/mm). For both systems, ultimate load was subject to interoperator variability. CONCLUSIONS: The Securos loops were significantly stronger and stiffer than the Veterinary Instrumentation loops for all operators, but significant differences between operators for ultimate load existed for both systems. CLINICAL RELEVANCE: Securos fabello-tibial sutures will withstand greater loads than Veterinary Instrumentation sutures and this is particularly true for sutures created by surgeons with reduced grip strength. It may be necessary to use more than 1 Veterinary Instrumentation suture to match the ultimate load and stiffness of a Securos suture.

Animals↗

Mechanical evaluation of two loop tensioning methods for crimp clamp extracapsular stabilization of the cranial cruciate ligament-deficient canine stifle.

OBJECTIVES: To describe a method of tightening nylon loops secured with a crimping system for extracapsular fabello-tibial stabilization of the cranial cruciate ligament-deficient stifle and to compare this with a method using a commercially available tensioning device. STUDY DESIGN: In vitro mechanical testing. METHODS: Fourteen standardized nylon loops were tensioned using a tensioning device and secured with crimp clamps. Another 14 loops were tightened by partially securing the crimp clamp, followed by tightening of the loop by hand, before definitively securing the crimp clamp. Loops were loaded to failure in a materials testing machine. RESULTS: Mean ultimate loads for instrument-tightened and hand-tightened loops were 383.7 and 371.4 N, respectively. Mean stiffness values for instrument-tightened and hand-tightened loops were 59.7 and 59.3 N/mm, respectively. These differences were not significant. CONCLUSIONS: The hand tightening method does not affect the mechanical properties of the loop. CLINICAL RELEVANCE: The hand tightening method described is a valuable technique for unassisted surgeons without access to tensioning devices.

Animals↗

Centre of mass movement and mechanical energy fluctuation during gallop locomotion in the Thoroughbred racehorse.

During locomotion cyclical interchange between different forms of mechanical energy enhances economy; however, 100% efficiency cannot be achieved and ultimately some mechanical work must be performed de novo. There is a metabolic cost associated with fluctuations in mechanical energy, even in the most efficient animals. In this study we investigate the exchanges between different forms of mechanical energy involved in high-speed gallop locomotion in Thoroughbred race horses during over-ground locomotion using innovative, mobile data collection techniques. We use hoof-mounted accelerometers to capture foot contact times, a GPS data logger to monitor speed and an inertial sensor mounted over the dorsal spinous processes of the fourth to sixth thoracic vertebrae (the withers) of the horse to capture trunk movement with six degrees of freedom. Trunk movement data were used to estimate the movement of the centre of mass (CoM). Linear (craniocaudal, mediolateral and dorsoventral) and rotational (roll, pitch and heading) kinematic parameters (displacement, velocity and acceleration) were calculated for seven horses at gallop speeds ranging from 7 to 17 m s(-1) during their regular training sessions. These were used to estimate external mechanical energy (potential energy and linear kinetic energy of the CoM) as well as selected components of internal energy (angular kinetic energy). Elastic energy storage in the limbs was estimated from duty factor, sine wave assumptions and published leg stiffness values. External mechanical energy changes were dominated by changes in craniocaudal velocity. Potential energy change, which was in phase with craniocaudal energy during the front limb stances, was small. Elastic energy storage in the limbs was small compared to the overall amplitude of fluctuation of external mechanical energy. Galloping at high speeds does not therefore fit classical spring mass mechanics.

Acceleration↗

Biomechanics: no force limit on greyhound sprint speed.

Maximum running speed is constrained by the speed at which the limbs can be swung forwards and backwards, and by the force they can withstand while in contact with the ground. Humans sprinting around banked bends change the duration of foot contact to spread the time over which the load is applied, thereby keeping the force on their legs constant. We show here that, on entering a tight bend, greyhounds do not change their foot-contact timings, and so have to withstand a 65% increase in limb forces. This supports the idea that greyhounds power locomotion by torque about the hips, so--just as in cycling humans--the muscles that provide the power are mechanically divorced from the structures that support weight.

Animals↗

A method for deriving displacement data during cyclical movement using an inertial sensor.

Biomechanical studies often employ optical motion capture systems for the determination of the position of an object in a room-based coordinate system. This is not ideal for many types of study in locomotion since only a few strides may be collected per ;trial', and outdoor experiments are difficult with some systems. Here, we report and evaluate a novel approach that enables the user to determine linear displacements of a proprietary orientation sensor during cyclical movement. This makes experiments outside the constraints of the laboratory possible, for example to measure mechanical energy fluctuations of the centre of mass during over-ground locomotion. Commercial orientation sensors based on inertial sensing are small and lightweight and provide a theoretical framework for determining position from acceleration. In practice, the integration process is difficult to implement because of integration errors, integration constants and the necessity to determine the orientation of the measured accelerations. Here, by working within the constraints of cyclical movements, we report and evaluate a method for determining orientation and relative position using a modified version of a commercial inertial orientation sensor that combines accelerometers, gyroscopes and magnetometers, thus giving a full set of movement parameters (displacement, velocity and acceleration in three dimensions). The 35 g sensor was attached over the spine of a horse exercising on a treadmill. During canter locomotion (9.0 m s-1), the amplitudes of trunk movement in the x (craniocaudal), y (mediolateral) and z (dorsoventral) directions were 99.6, 57.9 and 140.2 mm, respectively. Comparing sensor displacement values with optical motion capture values for individual strides, the sensor had a median error (25th, 75th percentile) in the x, y and z directions of 0.1 (-9.7, +10.8), -3.8 (-15.5, +13.7) and -0.1 (-6.3, +7.1) mm, respectively. High-pass filtering of the displacement data effectively separated non-cyclical from cyclical components of the movement and reduced the interquartile ranges of the errors considerably to (-3.6, 6.2), (-4.0, 3.8) and (-4.5, 5.1) for x, y and z displacement, respectively, during canter locomotion. This corresponds to (-3.2, 5.5)%, (-6.7, 6.3)% and (-3.3, 3.7)% of the range of motion.

Acceleration↗

Prediction of kinetics and kinematics of running animals using an analytical approximation to the planar spring-mass system.

The spring-mass model is often used to describe bouncing gaits. Although at first inspection the mechanical system appears simple, the solution to the motion cannot be derived easily. An analytical solution would provide a fast and intuitive method to determine the kinetic and kinematics of the centre of mass of terrestrial animals during over-ground steady state locomotion. Here, an analytical approximation using sine wave simplifications for the motion is presented. The analytical solution was almost indistinguishable from the numerical solution across initial leg angles of 17.5-30 degrees ; percentage differences between the analytical solution and the numerical solution were less than 1% for total mechanical energy, centre of mass position, total limb compression and centre of mass velocity and less than 2% different for resultant limb force and vertical acceleration of the centre of mass. The solution matched the relationship between stance time and speed collected from a trotting racehorse and accurately characterised previously published biological data. This study has shown that a simple analytical solution can predict the kinetics and kinematics of a spring-mass system over the range of biologically relevant sweep angles and horizontal velocities, and could be used to further understanding of limb deployment and gait selection. Using this analytical solution not only the force profile but also the changes in mechanical energy can be calculated from easily observed morphological and kinematic data.

Animals↗

The effect of gait and digital flexor muscle activation on limb compliance in the forelimb of the horse Equus caballus.

A horse's legs are compressed during the stance phase, storing and then returning elastic strain energy in spring-like muscle-tendon units. The arrangement of the muscle-tendon units around the lever-like joints means that as the leg shortens the muscle-tendon units are stretched. The forelimb anatomy means that the leg can be conceptually divided into two springs: the proximal spring, from the scapula to the elbow, and the distal spring, from the elbow to the foot. In this paper we report the results of a series of experiments testing the hypothesis that there is minimal scope for muscle contraction in either spring to adjust limb compliance. Firstly, we demonstrate that the distal, passive leg spring changes length by 127 mm (range 106-128 mm) at gallop and the proximal spring by 12 mm (9-15 mm). Secondly, we demonstrate that there is a linear relationship between limb force and metacarpo-phalangeal (MCP) joint angle that is minimally influenced by digital flexor muscle activation in vitro or as a function of gait in vivo. Finally, we determined the relationship between MCP joint angle and vertical ground-reaction force at trot and then predicted the forelimb peak vertical ground-reaction force during a 12 m s(-1) gallop on a treadmill. These were 12.79 N kg(-1) body mass (BM) (range 12.07-13.73 N kg(-1) BM) for the lead forelimb and 15.23 N kg(-1) BM (13.51-17.10 N kg(-1) BM) for the non-lead forelimb.

Animals↗