PubMed Health⌕ Search

Biomedical subjects

Alan Stolpen

Publications and source records attributed to Alan Stolpen.

8 recordsLinked to original sources

Bolus characteristics based on Magnetic Resonance Angiography.

BACKGROUND: A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA). Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA) for adaptive controller design and validation. METHODS: MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. RESULTS: The maximum speed of the bolus in the aorta ranged from 5-13 cm/s and the dwell time ranged from 7-13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. CONCLUSION: The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

Computer Simulation↗

Response assessment of aggressive non-Hodgkin's lymphoma by integrated International Workshop Criteria and fluorine-18-fluorodeoxyglucose positron emission tomography.

PURPOSE: To determine whether a response classification based on integration of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) into the International Workshop Criteria (IWC) provides a more accurate response assessment than IWC alone in patients with non-Hodgkin's lymphoma (NHL). PATIENTS AND METHODS: Fifty-four patients with aggressive NHL who underwent FDG-PET and computed tomography 1 to 16 weeks after four to eight cycles of chemotherapy with cyclophosphamide, doxorubicin, vincristine, and prednisone were assessed for complete response (CR), unconfirmed CR (CRu), partial response (PR), stable disease (SD), and progressive disease (PD) by the IWC and by integrated IWC and FDG-PET (IWC+PET). Progression-free survival (PFS) was also compared between IWC- and IWC+PET-assigned response designations. RESULTS: By IWC, 17 patients had a CR, seven had a CRu, 19 had a PR, nine had SD, and two had PD. In comparison, by IWC+PET, 35 patients had a CR, 12 had a PR, six had SD, one had PD, and zero had a CRu. In separate multivariate models, PFS was significantly shorter in patients with PR than in those with a CR using IWC (hazard ratio [HR], 8.9; P = .021) or IWC+PET (HR, 29.7; P = .0003). However, when the two classifications were included in the same multivariate model, only IWC+PET was a statistically significant independent predictor for PFS (P = .008 v P = .72 for IWC). In addition, when patients with a PR by IWC and a CR by IWC+PET were compared with those with a CR by IWC and a CR by IWC+PET, there was no significant difference in PFS (HR, 1.6; P = .72), indicating that IWC+PET identified a subset of IWC-PR patients with a more favorable prognosis. CONCLUSION: Compared with IWC, the IWC+PET-based assessment provides a more accurate response classification in patients with aggressive NHL.

Adult↗

A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging.

We developed and assessed a real-time 3-dimensional (3D) digital Doppler method for measurement of flow volumes through the mitral valve in children. A total of 13 children (aged 10.46 +/- 2.5 years; 8 boys/5 girls) were enrolled. An ultrasound system (Sonos 7500, Philips, Andover, Mass) was used to acquire raw 3D velocity data for flow measurement based on Gaussian control surface theorem [flow (mL/s) = mean velocity x flow area]. Stroke volume (SV) measured by real-time 3D digital Doppler with the control surface at the mitral valve annulus or orifice was compared with the SV by phase velocity cine magnetic resonance imaging (MRI) at the ascending aorta and by left ventricular volumetric MRI measurement. The best correlation and agreement were seen at the mitral valve orifice by real-time 3D digital Doppler compared with SV by phase velocity cine MRI at the ascending aorta (r = 0.92, mean difference = -5.2 +/- 12.0 mL) and SV by left ventricular volumetric MRI measurement (r = 0.94, mean difference = -0.2 +/- 10.3 mL).

Adolescent↗

Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: a validation study compared with magnetic resonance imaging.

OBJECTIVE: We sought to assess the feasibility, accuracy, and reproducibility of a rapid full volume acquisition strategy using real-time (RT) 3-dimensional (3D) echocardiography (3DE) for measurement of left ventricular (LV) volumes, mass, stroke volume (SV), and ejection fraction (EF) in children. METHODS: A total of 19 healthy children (mean 10.6 +/- 2.8 years, 11 male and 9 female) were prospectively enrolled in this study. RT 3DE was performed using an ultrasound system to acquire full volume 3D dataset from the apical window with electrocardiographic triggering in 8 s/dataset. The images were processed offline using software. The LV endocardial and epicardial borders were traced manually to derive LV end-systolic volume, end-diastolic volume, mass, SV, and EF. Magnetic resonance imaging (MRI) studies were performed on a 1.5-T scanner using a breath hold 2-dimensional cine-FIESTA (fast imaging employing steady-state acquisition) sequence. RESULTS: All RT 3DE and MRI data were acquired successfully for analysis. Measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF by RT 3DE correlated well by Pearson regression ( r = 0.86-0.97, P < .001) and agreed well by Bland-Altman analysis with MRI. The interobserver and intraobserver variability of RT 3DE measurements were less than 5%. CONCLUSIONS: This prospective study demonstrated that RT 3DE measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF in children using rapid full volume acquisition strategy are feasible, accurate, and reproducible and are comparable with MRI measurements.

Adolescent↗

Does variant hepatic artery anatomy in a liver transplant recipient increase the risk of hepatic artery complications after transplantation?

OBJECTIVE: Our aim was to determine whether variant hepatic artery anatomy in a liver transplant recipient increases the risk of hepatic artery complications after liver transplantation. MATERIALS AND METHODS: The study group consisted of 84 patients who underwent gadolinium-enhanced 3D MR angiography before orthotopic liver transplantation in which a branch patch arterial anastomosis at the gastroduodenal takeoff was used. MR angiography studies were retrospectively reviewed and assessed for the presence and type of variant hepatic artery anatomy. The diameter of the distal common hepatic artery was measured. The incidence of posttransplantation hepatic artery stenosis or thrombosis was assessed. RESULTS: Seven (8.3%) of the 84 patients developed hepatic artery complications after transplantation. Of the 24 patients with variant hepatic artery anatomy, five (20.8%) had posttransplantation/ hepatic artery complications. In contrast, only two (3.3%) of the 60 patients with classic hepatic artery anatomy had complications. The higher complication rate in patients with variant hepatic artery anatomy was statistically significant (p < 0.05). The odds ratio was 7.6 (95% confidence interval, 1.4-42.6). The diameter of the distal common hepatic artery was smaller in patients with variant hepatic artery anatomy compared with those with classic hepatic artery anatomy (range, 4.3-7.1 mm [mean, 5.8 mm] vs 4.0-8.9 mm [mean 6.3 mm], p < 0.05), and it was also smaller in patients who had posttransplantation hepatic artery complications compared with those who had no complications (range, 4.2-6.3 mm [mean, 5.2 mm] vs 4.0-8.9 mm, [mean, 6.2 mm], p < 0.01). CONCLUSION: Variant hepatic artery anatomy in a liver transplant recipient increased the risk of hepatic artery complications after transplantation. The smaller caliber of the native common hepatic artery may contribute to the higher risk.

Adolescent↗

Segmentation of wall and plaque in in vitro vascular MR images.

Atherosclerosis leads to heart attack and stroke, which are major killers in the western world. These cardiovascular events frequently result from local rupture of vulnerable atherosclerotic plaque. Non-invasive assessment of plaque vulnerability would dramatically change the way in which atherosclerotic disease is diagnosed, monitored, and treated. In this paper, we report a computerized method for segmentation of arterial wall layers and plaque from high-resolution volumetric MR images. The method uses dynamic programming to detect optimal borders in each MRI frame. The accuracy of the results was tested in 62 T1-weighted MR images from six vessel specimens in comparison to borders manually determined by an expert observer. The mean signed border positioning errors for the lumen, internal elastic lamina, and external elastic lamina borders were -0.1 +/- 0.1, 0.0 +/- 0.1, and -0.1 +/- 0.1 mm, respectively. The presented wall layer segmentation approach is one of the first steps towards non-invasive assessment of plaque vulnerability in atherosclerotic subjects.

Arteriosclerosis↗

Projection-based bolus detection for computed tomographic angiography.

Computed tomographic (CT) angiography is important for imaging studies on cardiovascular structures, peripheral vessels, and solid organs. In practice, a CT angiography scan is triggered by the bolus arrival at a prespecified anatomical location, which is determined using CT fluoroscopy. In this article, we propose a projection-based method adapted from the Grangeat formula to detect the bolus arrival. Then, we evaluate our new method in numerical and animal studies. Our results indicate that this method allows significantly better temporal resolution and is computationally more efficient, as compared with the image-based methods.

Algorithms↗