Intracorneal ring segments for keratoconus correction: long-term follow-up.

PURPOSE: To evaluate long-term results and stability of intracorneal ring segment (Intacs) implantation for keratoconus correction. SETTING: Vissum, Instituto Oftalmológico de Alicante and University of Miguel Hernandez, Alicante, Spain. METHODS: This retrospective study comprised 13 eyes operated on between April 2000 and December 2001 that had Intacs implantation for keratoconus correction. The outcomes were evaluated at 6, 12, 24, and 36 months in all eyes and at 48 months (6 eyes). RESULTS: Mean best spectacle-corrected visual acuity (BSCVA) increased from 0.46 (20/50) preoperatively to 0.66 (20/30) postoperatively (P< or =.001). Mean decrease of inferior-superior (I-S) asymmetry was 2.81 diopters (D) (P< or =.02), and the average K-value was 3.13 D (P< or =.001). Mean difference between 6 and 36 months (stability) showed no significant difference regarding BSCVA (P< or =.5) and I-S asymmetry (P< or =.6). Although a significant increase was noticed in the average K by 1.67 D (P< or =.002), at 36 months it did not reach the initial preoperative values. CONCLUSION: Intacs increased the BSCVA and decreased I-S asymmetry with stability up to 36 months. In spite of the decrease of the K-values at 6 months, a further significant increase was detected 36 months after surgery.

Adult↗

Evidence for delayed presbyopia after photorefractive keratectomy for myopia.

PURPOSE: To evaluate uncorrected near visual acuity (NVA), accommodation, corneal aberrations, and the optical quality of the retinal image in presbyopic eyes after photorefractive keratectomy (PRK). DESIGN: Nonrandomized comparative retrospective study. PARTICIPANTS: Ten post-PRK patients and 10 normal patients. METHODS: Twenty eyes (10 right and 10 left after PRK for myopia, minimum of 10 years after the operation; group A) were compared with 20 eyes (10 right and 10 left age- and gender-matched normal controls; group B). All subjects were over 40 years of age. MAIN OUTCOME MEASURES: With best distance correction, NVA was measured at 40 cm (Jaeger, J series), and the range of accommodation (diopters [D]) was measured subjectively (negative relative amplitude and positive relative amplitude). The modulation transfer function (MTF) and corneal aberrations such as comalike, spherical (SAs), and higher order (HOAs) were measured with a Hartmann-Shack aberrometer. From the MTF curves, the spatial frequencies corresponding to contrast values of 0.1 and 0.5 were noted. RESULTS: Mean ages (+/- standard deviations [SDs]) were 46.3 years (4.7) for group A and 47.6 years (4.9) for group B (P>0.05). Near acuity was J1 or better in 12 of 20 post-PRK and 4 of 20 control eyes. Mean accommodations (+/- SDs) were 3.2 D (1.14) for right group A eyes and 2.1 D (0.94) for right group B eyes (P = 0.0152), and 3.4 D (0.99) for left A eyes and 2.3 D (1.02) for left B eyes (P = 0.0168). Total HOA indexes (+/- SDs) were 1.449 (0.409) for right group A eyes and 0.824 (0.241) for right group B eyes (P = 0.008), and 1.464 (0.388) for left A eyes and 1.067 (0.542) for left B eyes (P = 0.0752). Pooling the data from post-PRK and control eyes, a significant correlation was found between near acuity and SA (right eyes, r = -0.535, P = 0.015; left eyes, r = -0.493, P = 0.027). Significant associations were found between accommodation, near acuity, HOA, and comalike aberration for right eyes only. Mean spatial frequencies (+/- SDs) corresponding to contrast values of 0.1 for right and left eyes were 14.96 (5.71) for right group A eyes and 22.02 (6.85) for right group B eyes (P = 0.074), and 15.11 (7.80) for left A eyes and 21.41 (9.00) for left B eyes (P = 0.271). Mean spatial frequencies (+/- SDs) corresponding to contrast values of 0.5 for right and left eyes were 2.86 (0.63) for right group A eyes and 3.21 (0.35) for right group B eyes (P = 0.596), and 2.76 (0.98) for left A eyes and 3.22 (0.27) for left B eyes (P = 0.194). CONCLUSIONS: Compared with normal eyes, in previously myopic eyes treated with first-generation PRK lasers there is a tendency for (1) the optical quality of the retinal image to be reduced at low contrast, (2) the aberrations attributed to the corneal surface to increase, and (3) both measured subjective accommodation and near acuity to be greater than expected. We postulate that the corneal aberrations induced by PRK for myopia may reduce the quality of the retinal image for distance but enhance near acuity by way of a multifocal effect that can delay the onset of age-related near vision symptoms.

Accommodation, Ocular↗

Interface corneal edema secondary to steroid-induced elevation of intraocular pressure simulating diffuse lamellar keratitis.

PURPOSE: To describe interface corneal edema secondary to steroid-induced elevation of intraocular pressure (IOP) following LASIK. METHODS: Retrospective observational case series. Diffuse interface edema secondary to steroid-induced elevation of IOP was observed after LASIK simulating diffuse lamellar keratitis (DLK) in 13 eyes. Mean patient age was 31.4 +/- 5.3 years. Patients were divided into two groups according to provisional misdiagnosis: DLK group (group 1) comprised 11 eyes and infection group (group 2) comprised 2 eyes (microbial keratitis). Mean follow-up was 8.1 +/- 0.5 weeks. RESULTS: In the DLK group, typical diffuse haze was confined to the interface and extended to the visual axis, impairing vision in all eyes. Provisional diagnosis was late-onset DLK and topical steroids were started. Repeat examination showed elevated IOP as measured at the corneal center and periphery using applanation tonometry (mean 19.1 mmHg and 39.5 mmHg, respectively), causing interface edema with evident interface fluid pockets. Steroids were stopped and topical anti-glaucoma therapy was started. The interface edema decreased and at the end of follow-up the corneal transparency was restored and IOP dropped to normal values. The infection group demonstrated a microbial keratitis-like reaction and underwent flap lifting and interface wound debridement and biopsy with administration of fortified antibiotics and steroids. After elevated IOP was detected, steroids and antibiotics were stopped and topical anti-glaucoma therapy was started, resulting in the resolution of the interface edema. CONCLUSIONS: Interface fluid syndrome secondary to steroid-induced elevation of IOP might develop in steroid responders after LASIK with a misleading clinical picture simulating DLK or infectious keratitis. Management includes stopping topical steroids and starting topical antiglaucoma therapy.

Adult↗

LASIK in myopic patients with dermatological keloids.

PURPOSE: To evaluate the visual and refractive out come of LASIK in myopic patients with a known history of dermatological keloid scar. METHODS: This retrospective case series included 10 eyes of 5 white patients with a known history of dermatological keloids. All patients had low to moderate myopia with no corneal or limbal keloid. All underwent uneventful bilateral LASIK. Postoperatively, visual outcomes, refractive outcomes, and complications were evaluated. Minimum 1-year follow-up was indicated for all patients in this study. RESULTS: Mean preoperative uncorrected visual acuity (UCVA) was 20/320 and 1 year postoperative 20/20. Mean preoperative best spectacle-corrected visual acuity (BSCVA) was 20/25 and 1 year postoperative was 20/20. The mean preoperative spherical equivalent refraction was -5.00 +/- 2.6 diopters (D) and +0.1 +/- 0.2 D 1 year postoperative. The safety index was 1.02 and the efficacy index was 1.02. None of the included in this study underwent retreatment for correction of residual error or regression up to 1 year postoperatively. No sight-threatening complications were reported. No patient reported postoperative haze, severe dry eye syndrome, or flap-related problems. CONCLUSIONS: LASIK is a safe, effective, and predictable technique for correcting low and moderate myopia in patients with dermatological keloids.

Adult↗

Hyperopic LASIK retreatments with the Technolas laser.

PURPOSE: To evaluate the safety, efficacy, and predictability of hyperopic LASIK retreatments. METHODS: This retrospective, consecutive, non-comparative, observational study included 85 eyes that underwent hyperopic LASIK retreatment with 1-year follow-up. Complete ophthalmic examination included distance uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA), cycloplegic refraction, and pachymetry. Patients were divided into two groups according to the preoperative spherical equivalent refraction: group 1, < or = +3.9 diopters (D) and group 2, > or = +4.0 D. RESULTS: The UCVA improved from 0.31 +/- 0.2 to 0.7 +/- 0.2 in group 1 and from 0.2 +/- 0.2 to 0.6 +/- 0.2 in group 2 following retreatment. Mean spherical equivalent refraction improved from +2.8 +/- 0.85 to +0.2 +/- 0.9 in group 1 and from +5.3 +/- 0.9 to +0.3 +/- 1.3 in group 2 after retreatment. In group 1, 32 (72.7%) of 44 eyes had BSCVA > or = 20/25, and in group 2, 24 (58.5%) of 41 eyes had BSCVA > or = 20/25. After primary hyperopic LASIK, 25 (56.8%) of 44 eyes in group 1 and 19 (46.3%) of 41 eyes in group 2 maintained BSCVA or gained > or = 1 lines postoperatively in contrast to 21 (47.7%) of 44 eyes in group 1 and 22 (53.9%) of 41 eyes in group 2 after retreatment. In group 1, 11 (25%) of 44 eyes lost > or = 2 lines of BSCVA after initial hyperopic LASIK compared to 14 (31.8%) of 44 eyes after retreatment. In group 2, 10 (24.4%) of 41 eyes lost > or = 2 lines of BSCVA after initial hyperopic LASIK compared to 12 (29.2%) of 41 eyes after retreatment. After hyperopic LASIK retreatment, 31 (70.5%) of 44 eyes in group 1 and 19 (46.4%) of 41 eyes in group 2 were within +/- 0.5 D of emmetropia. Safety was 0.9 in both groups and efficacy was 0.8 and 0.7 in groups 1 and 2, respectively. Complications included epithelial ingrowth of 1 to 3 mm (30%) and flap edge melting (2%). CONCLUSIONS: Hyperopic LASIK retreatment improved the refractive results of initial hyperopic LASIK surgery with 20% to 30% of eyes gaining > or = 1 lines of BSCVA. The loss of BSCVA was greater after primary hyperopic LASIK than after retreatment.

Adult↗

Hyperopic LASIK with Esiris/Schwind technology.

PURPOSE: To investigate the refractive and visual outcomes of hyperopic LASIK using Esiris/Schwind technology. METHODS: This retrospective non-comparative observational study included 106 eyes (65 patients) operated with the Esiris/Schwind laser for hyperopia. Eyes were divided into two groups: group 1, < or = +3.99 diopters (D) and group 2, > or = +4.0 D (up to +7.0 D). Visual outcome for distance and near uncorrected (UCVA) and best spectacle-corrected visual acuities (BSCVA) (decimal values), cycloplegic refraction, keratometry (K), pachymetry, and complications were evaluated. RESULTS: In group 1, mean UCVA was 0.4 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 1.1 and efficacy index was 0.97. Mean spherical equivalent refraction was +2.33 +/- 0.9 D preoperatively and +0.3 +/- 0.3 D 6 months postoperatively. Mean K reading was 43.7 +/- 1.1 D preoperatively and 45.0 +/- 1.6 D 6 months postoperatively. In group 2, mean UCVA was 0.3 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 0.98 and efficacy index was 0.92. Mean spherical equivalent refraction was +5.1 +/- 0.9 D preoperatively and +0.4 +/- 0.5 D 6 months postoperatively. Mean K reading was 43.1 +/- 1.6 D preoperatively and 46.0 +/- 1.4 D 6 months postoperatively. Forty-six (90.2%) of 51 eyes in group 1 and 47 (85.5%) of 55 eyes in group 2 were within +/- 0.5 D of emmetropia. At 6-month follow-up, 40 (78%) of 51 eyes in group 1 had UCVA of 20/20 compared to 41 (75%) of 51 eyes in group 2. One (2%) of 51 eyes in group 1 and 4 (7.3%) of 55 eyes in group 2 lost < or = 2 lines of BSCVA. No eye lost >2 lines of BSCVA. CONCLUSIONS: Hyperopic LASIK with Esiris/Schwind technology is effective and safe in the correction of hyperopia up to + 7.0 D. Although a slight statistical significance was found for low hyperopia, visual and refractive results obtained in high hyperopia were encouraging.

Adult↗

LASIK in patients with rheumatic diseases: a pilot study.

PURPOSE: To investigate the safety of LASIK in patients with a known history of controlled rheumatic diseases. DESIGN: Retrospective consecutive observational clinical study. PARTICIPANTS: Forty-two eyes (22 patients) known to have had a history of rheumatic diseases underwent LASIK. All patients had a history of controlled rheumatic diseases, including rheumatoid arthritis, systemic lupus erythematosus, dermatomyositis, scleroderma, ankylosing spondylitis, psoriatic arthritis, inflammatory bowel disease, arthritis, or Behçet's disease. METHODS: Assessments were made preoperatively and at 1, 3, and 6 months postoperatively and included visual acuity (VA), refraction, keratometric readings, slit-lamp biomicroscopy, and corneal topography. All the patients underwent LASIK. Postoperative treatment included a topical steroid-antibiotic combination. MAIN OUTCOME MEASURES: Visual acuity, refraction, keratometric readings, and slit-lamp biomicroscopy findings at 1, 3, and 6 months postoperatively. RESULTS: LASIK was performed uneventfully on all patients. The mean pre-LASIK spherical equivalent (SE) was -5.39+/-2.25, and the sixth month postoperative SE was -0.15+/-0.38 diopters (D) (P<0.001). Uncorrected VA 6 months after the LASIK procedure was 20/25. Enhancement procedures were performed in 6 of 42 eyes (14.3%) at variable times after the primary procedure. Postoperative follow-up showed development of a moderate degree of dry eye syndrome in 4 eyes (9.5%). Corneal haze, melting, flap, or interface complications were not observed in any of the study eyes. CONCLUSIONS: In this small series, we found good outcomes when correcting refractive errors using LASIK in selected patients with controlled rheumatic diseases. In this series, a favorable postoperative visual outcome was obtained with no operative or postoperative vision-threatening complications.

Adult↗

One or 2 Intacs segments for the correction of keratoconus.

PURPOSE: To evaluate the effect of implanting 1 or 2 intracorneal rings (Intacs, KeraVision) as a device to correct, stabilize, and/or improve the best corrected visual acuity in patients with clear cornea keratoconus oriented by the preoperative corneal topography pattern. SETTING: Vissum/Instituto Oftalmológico de Alicante, Miguel Hernandez University, Alicante, Spain. METHODS: In this prospective comparative consecutive study, Intacs segments were implanted in 26 keratoconic eyes with clear central corneas of 19 consecutive patients (9 women and 10 men). Corneas were divided into 2 groups according to the topographic pattern of the cone. Group I included keratoconus not crossing the 180 degrees meridian and Group II included keratoconus crossing the 180 degrees meridian. The Intacs were horizontally placed through a lateral clear corneal incision. According to the corneal topography 1 segment was implanted 0.45 mm inferior in Group I, and 2 segments were implanted, 1 0.25 mm superior and the other 0.45 mm inferior, in Group II. All cases completed a minimum follow-up of 1 year. Differences between preoperative and postoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and keratometry were clinically and statistically evaluated. RESULTS: Spherical equivalent error and refractive astigmatism were significantly reduced. The mean keratometric values were reduced following Intacs insertion in both groups. At the end of the first year of the postoperative follow-up, Group I (1 segment) had an improvement in mean UCVA to 20/50 (0.4 +/- 0.22 decimal value), which was statistically significant when compared to the preoperative UCVA of 20/100 (0.2 +/- 0.13 decimal value) (P=.011). Mean BSCVA was 20/32 (0.62 +/- 0.24 decimal value), which was also statistically significant when compared to the preoperative BSCVA, which was 20/50 (0.4 +/- 0.21 decimal value) (P=.002). In Group II (2 segments), UCVA after 1 year was 20/63 (0.34 +/- 0.17 decimal value), which was statistically significant when compared to the preoperative UCVA of 20/400 (0.06 +/- 0.02 decimal value) (P=.001). Mean BSCVA was 20/32 (0.62 +/- 0.27 decimal value), which was significantly better than the preoperative UCVA of 20/50 (0.38 +/- 0.22 decimal value) (P=.001). In 4 eyes, the inferior segment was removed because of partial extrusion during the postoperative follow-up. CONCLUSIONS: Treatment of keratoconus with 1 or 2 Intacs segments oriented by the preoperative corneal topography used in this study proved to be effective in decreasing the corneal steepening and astigmatism and improving BSCVA. Further follow-up is needed to determine the final effect of Intacs on the progression of the corneal disease.

Adult↗

Hyaluronic acid combined with mannitol to improve protection against free-radical endothelial damage: experimental model.

PURPOSE: To evaluate the protective properties of combined sodium hyaluronate 2% and mannitol 0.5% (Visiol) on the corneal endothelium in the presence of oxidative stress induced by hydrogen peroxide (H(2)O(2)). SETTING: Instituto Oftalmológico de Alicante, Universidad Miguel Hernández, Alicante, Spain. METHODS: This was an exploratory randomized controlled parallel-group, masked-assessor study of 3 sodium hyaluronate-based ophthalmic viscosurgical devices (OVDs): Visiol, Healon (sodium hyaluronate 1%), and Viscoat (sodium hyaluronate 3%-chondroitin sodium 4%). The OVDs were tested for protective effects on the endothelium following oxidative stress induced by H(2)O(2) at increased concentrations: control (lactated Ringer's solution), 1 mM, 10 mM, and 100 mM. Groups without OVD were used as controls at the same concentrations of peroxide. Each animal received the same treatment in both eyes (10 eyes per group). Endothelial cell lesion was assessed using the Janus green photometry absorbance technique. RESULTS: At 10 mM peroxide concentration, the value of endothelial cell lesion was significantly lower in the Visiol (16.8%, P=.0056), Healon (22.2%, P=.0302), and Viscoat (21.6%, P=.0336) groups than in the control group (29.4%, no OVD). There was a trend in favor of Visiol to more efficiently reduce cell lesions of the endothelium, than Healon (P=.055) and Viscoat (P=.1013). Values of endothelial cell lesion at peroxide concentrations of 1 mM and 100 mM showed the same trends than those observed at 10 mM. CONCLUSIONS: All of the OVDs tested efficiently reduced endothelial lesions against free radicals compared with the control group in which no OVD was used. The following sequence for the efficacy of endothelial cell protection was established: Visiol>Viscoat>Healon>no OVD.

Animals↗

Severe corneal epithelial sloughing during laser in situ keratomileusis as a presenting sign for silent epithelial basement membrane dystrophy.

PURPOSE: To report the occurrence of large intraoperative epithelial sloughing during laser in situ keratomileusis (LASIK) as a first diagnostic sign for silent epithelial basement membrane dystrophy (EBMD). SETTING: Refractive Surgery and Cornea Unit, Alicante Institute of Ophthalmology, Alicante, Spain. METHODS: In this retrospective case series, the medical records of all patients with large corneal epithelial sloughing/defects during LASIK from January 1995 to December 2004 were reviewed. All patients who presented normal corneas before LASIK and EBMD changes after LASIK were included in this study. The surgical procedures and postoperative course were recorded. The follow-up period was 12 months for all patients. RESULTS: Eleven eyes of 6 patients were included. The mean age was 35 years +/- 6.1 (SD). Mean preoperative uncorrected visual acuity (UCVA) was 20/500 (0.04 +/- 0.02); 12 months after surgery, mean UCVA increased to 20/27 (0.74 +/- 0.21). There was a significant decrease in best spectacle-corrected visual acuity 1 month after surgery. One year postoperatively, 10 of 11 eyes (91%) were within +/-1.00 diopter of emmetropia. Postoperatively, clinical manifestations of EBMD were observed in all eyes and complications were common. In the early postoperative period, diffuse lamellar keratitis was observed in 6 of 11 eyes (54.5%) and flap microfolds were noted in 2 of 11 (18.2%). One year after surgery, epithelial ingrowth was present in 8 of 11 eyes (72.7%) and flap melting was noted in 4 of 11 (36.4%). CONCLUSION: Occurrence of large intraoperative epithelium sloughing/defects during LASIK might be a diagnostic sign for subclinical EBMD. These patients are predisposed to multiple postoperative complications. Because of the high risk for epithelial sloughing in the second eye, LASIK should not be performed.

Adult↗

Changes in keratoconic corneas after intracorneal ring segment explantation and reimplantation.

PURPOSE: To evaluate the outcome and potential reversibility of the changes induced in keratoconic eyes after intracorneal ring segment explantation. DESIGN: Retrospective, interventional case series. PARTICIPANTS: Five eyes of 4 patients who underwent uneventful implantation of one or two intracorneal ring segment segments for the correction of clear corneal keratoconus and who required explantation of one segment due to complications. MAIN OUTCOME MEASURES: Visual acuity, refraction, keratometric readings, and corneal topography. The follow-up was up to 1 year from the primary implantation procedure in all cases. RESULTS: Explantation was performed easily in all cases without intraoperative or postoperative complications. The segments were extracted due to migration and local melting. The visual, refractive, and topographic map findings regressed to approximate the original clinical situation before segment implantation. CONCLUSIONS: Intracorneal ring segments are safely and easily explanted from keratoconic eyes. Most of the visual, refractive, and topographic findings return to near the preimplantation levels.

Adult↗

Ulcerative keratitis caused by Serratia marcescens after laser in situ keratomileusis.

We report 2 cases of severe corneal infections caused by Serratia marcescens after laser in situ keratomileusis (LASIK). Twenty-four hours after LASIK, 2 patients developed infectious keratitis, 1 bilaterally. In each eye, the corneal flap was edematous, ulcerated, and detached from the stromal bed. Treatment included removal of the necrotic flap and aggressive antibiotic therapy. Cultures from corneal exudates were positive for S marcescens. After 1 year, both patients had a loss of best corrected visual acuity (BCVA) ranging from 20/40 to 20/22 because of irregular astigmatism. Overrefraction with a hard contact lens resulted in a BCVA of 20/20 in the 3 affected eyes. Slitlamp examination showed trace subepithelial haze without severe corneal scarring. Videokeratography disclosed areas of paracentral inferior steepening resembling keratoconus. Refraction and videokeratography remained stable after 6 months of follow-up. Ulcerative keratitis caused by S marcescens is a potential complication of LASIK. Bilateral involvement may occur if bilateral simultaneous surgery is performed.

Adult↗

Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis.

PURPOSE: To evaluate the potential of using intrastromal corneal ring technology (Intacs, KeraVision) to correct posterior ectasia after laser in situ keratomileusis (LASIK) for myopia. SETTING: Department of Cornea and Refractive Surgery, Instituto Oftalmológico de Alicante, and Miguel Hernández University School of Medicine, Alicante, Spain. METHODS: In this prospective noncomparative intervention case series, Intacs segments were implanted in 3 eyes that developed posterior ectasia after myopic LASIK with clear central corneas. Posterior ectasia and corneal thickness were tested using the Orbscan II Slit Scanning Corneal Topography/Pachymetry System (Orbtek Inc.). Segment thickness varied based on corneal topography analysis and refraction. The mean follow-up was 8.3 months (range 7 to 11 months). RESULTS: The cases showed marked improvement after Intacs segment implantation. Postoperatively, there was a reduction in the magnitude of the posterior and anterior corneal surface steepening or ectasia and an increase in the topographical regularity index. In addition, the significantly enlarged optical zones resulted in a favorable visual outcome. In 2 eyes, the uncorrected visual acuity (UCVA) was 20/40 postoperatively. In the third eye, there was a residual refractive error; the UCVA was 20/50 and the best spectacle-corrected visual acuity, 20/40. CONCLUSIONS: Intacs intrastromal corneal rings used as a mechanical device may alter the biomechanical properties of the cornea for the correction of iatrogenic keratectasia and the associated residual myopia.

Adult↗

Comparison of corneal pachymetry using ultrasound and Orbscan II.

PURPOSE: To compare Orbscan II pachymetry with ultrasonic pachymetry in eyes having corneal refractive surgery. SETTING: Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS: In this comparative prospective study, 72 eyes (36 patients) were divided into 4 groups: Group 1, 16 eyes with haze after photorefractive keratectomy (PRK); Group 2, 12 eyes with no haze after PRK; Group 3, 24 eyes that had uneventful laser in situ keratomileusis; Group 4, 20 normal eyes. The corneal thickness was measured in all eyes by the Orbscan II (version 3.27.10, Orbtek Inc.) and then by ultrasonic pachymetry (DHC 500, Technology Inc.). RESULTS: The results between the 2 systems of pachymetry were significant in Group 1 (P < .0001) and not significant in Groups 2, 3, and 4 (P = .056, P = .051, and P = .68, respectively). A statistically significant correlation existed between the grade of haze and the decrease in Orbscan readings (C = -0.821, P < .0001). CONCLUSION: The Orbscan II pachymetry measurements correlated with the ultrasound measurements in eyes with clear corneas. Haze after PRK decreased the Orbscan pachymetry.

Adult↗

Contact lens fitting to correct irregular astigmatism after corneal refractive surgery.

PURPOSE: To study a technique of contact lens fitting and its visual results in patients with irregular astigmatism induced by corneal refractive surgery. SETTING: Department of Cornea and Refractive Surgery, Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS: This prospective noncomparative study comprised 29 eyes with irregular astigmatism after corneal refractive surgery. Different types of contact lenses were used to correct the astigmatism: hard, gas permeable, hybrid, and toric hydrophilic. Preoperative and postoperative data were analyzed for proper fitting including the preoperative keratometeric reading and corneal ablation zone. RESULTS: Proper contact lens fitting was achieved in 23 eyes (79.3%). In 6 eyes (20.7%), fitting was not possible despite an improvement in best corrected visual acuity (BCVA). Of the eyes with proper fitting, 14 (60.9%) had rigid gas-permeable lenses (9.80 mm), 6 (26.1%) had hydrophilic lenses (14.00 mm), and 3 (13.0%) had hybrid lenses (14.3 mm). Comparing the BCVA with that with spectacles, 23 eyes (79.3%) gained 2 lines or more of BCVA, 4 (13.8%) gained 1 line, and 2 (6.9%) maintained the same acuity as with spectacles. No eye lost lines of BCVA. CONCLUSIONS: Results indicate that contact lens fitting is a good-and sometimes the only-alternative for patients with induced irregular astigmatism. Rigid gas-permeable contact lenses provided the best visual performance and patient tolerance.

Adult↗

Macular hole in a myopic eye after laser in situ keratomileusis.

PURPOSE: To analyze the characteristics of a macular hole in a myopic patient after laser in situ keratomileusis (LASIK). METHODS: A macular hole with sharp margins and small yellow deposits on the surface of the retinal pigment epithelium appeared in the left eye of a female patient, 53 years old, 12 months after LASIK for the correction of -6.75 D of myopia (follow-up after LASIK, 22 months). Best spectacle-corrected visual acuity (BSCVA) before LASIK was 20/25. BSCVA after LASIK was 20/20 (spherical equivalent refraction -1.00 D). After the macular hole appearance, BSCVA was 20/100. The macular hole was treated by vitrectomy with internal-limiting membrane peeling. Final BSCVA was 20/50. CONCLUSION: The role of LASIK in the pathogenesis of macular hole remains unclear.

Eyeglasses↗

Diffuse lamellar keratitis 6 months after uneventful laser in situ keratomileusis.

PURPOSE: Diffuse lamellar keratitis after laser in situ keratomileusis (LASIK) typically occurs between 1 and 7 days after the procedure, and its etiologic factor(s) remain unknown. METHODS: We describe a case of diffuse lamellar keratitis 6 months after uneventful LASIK in a 25-year-old woman. RESULTS: Slit-lamp microscopy showed a diffuse infiltrate confined to the interface, extending to the visual axis, with no other relevant findings. Late on-set diffuse lamellar keratitis was our provisional diagnosis and treatment with topical corticosteroids was instituted, with rapid response and improvement of the clinical signs and symptoms. CONCLUSIONS: This case supports the theory that a previously inert inciting agent could cause a delayed toxic or inflammatory response of the cornea several months after surgery.

Adult↗