Differential near-field scanning optical microscopy.

We theoretically and experimentally illustrate a new apertured near-field scanning optical microscopy (NSOM) technique, termed differential NSOM (DNSOM). It involves scanning a relatively large (e.g., 0.3-2 mum wide) rectangular aperture (or a detector) in the near-field of an object and recording detected power as a function of the scanning position. The image reconstruction is achieved by taking a two-dimensional derivative of the recorded power map. Unlike conventional apertured NSOM, the size of the rectangular aperture/detector does not determine the resolution in DNSOM; instead, the resolution is practically determined by the sharpness of the corners of the rectangular aperture/detector. Principles of DNSOM can also be extended to other aperture/detector geometries such as triangles and parallelograms.

Equipment Design↗

Noise-reduction capabilities of a raman-mediated wavelength converter.

We describe ultrawideband Raman-mediated wavelength conversion. The nonlinear conversion transfer function is calculated analytically and simulated numerically in the cw regime, and the predicted performance is confirmed experimentally. Data conversion from long- to short-wavelength bands with signal reshaping and significant noise reduction are demonstrated experimentally at 10 Gbits/s and modeled by numerical simulations. Q factors and extinction ratios that are both larger than 10 dB are possible over an effective conversion bandwidth of 35 nm.

Journal Article↗

Measurement of fibrous cap thickness in atherosclerotic plaques by spatiotemporal analysis of laser speckle images.

Necrotic-core fibroatheromas (NCFA) with thin, mechanically weak fibrous caps overlying lipid cores comprise the majority of plaques that rupture and cause acute myocardial infarction. Laser speckle imaging (LSI) has been recently demonstrated to enable atherosclerotic plaque characterization with high accuracy. We investigate spatio-temporal analysis of LSI data, in conjunction with diffusion theory and Monte Carlo modeling of light transport, to estimate fibrous cap thickness in NCFAs. Time-varying laser speckle images of 20 NCFAs are selected for analysis. Spatio-temporal intensity fluctuations are analyzed by exponential fitting of the windowed normalized cross-correlation of sequential laser speckle patterns to obtain the speckle decorrelation time constant, tau(rho), as a function of distance rho from the source entry location. The distance, rho', at which tau(rho) dropped to 65% of its maximum value is recorded. Diffusion theory and Monte Carlo models are utilized to estimate the maximum photon penetration depth, zmax(rho'), for a distance equal to rho', measured from LSI. Measurements of zmax(rho') correlate well with histological measurements of fibrous cap thickness (R=0.78, p<0.0001), and paired t-tests show no significant difference between the groups (p=0.4). These results demonstrate that spatio-temporal LSI may allow the estimation of fibrous cap thickness in NCFAs, which is an important predictor of plaque stability.

Algorithms↗