PubMed Health⌕ Search

Biomedical subjects

Alberto Schillaci

Publications and source records attributed to Alberto Schillaci.

7 recordsLinked to original sources

Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies.

PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multi-detector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis. RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%. CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.

Aged↗

Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps.

BACKGROUND AND AIMS: We prospectively compared the performance of low-dose multidetector computed tomographic colonography (CTC) without cathartic preparation with that of colonoscopy for the detection of colorectal polyps. METHODS: A total of 203 patients underwent low-dose CTC without cathartic preparation followed by colonoscopy. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. No subtraction of tagged feces was performed. Colonoscopy was performed 3-7 days after CTC. Three readers interpreted the CTC examinations separately and independently using a primary 2-dimensional approach using multiplanar reconstructions and 3-dimensional images for further characterization. Colonoscopy with segmental unblinding was used as reference standard. The sensitivity of CTC was calculated both on a per-polyp and a per-patient basis. For the latter, specificity, positive predictive values, and negative predictive values were also calculated. RESULTS: CTC had an average sensitivity of 95.5% (95% confidence interval [CI], 92.1%-99%) for the identification of colorectal polyps > or =8 mm. With regard to per-patient analysis, CTC yielded an average sensitivity of 89.9% (95% CI, 86%-93.7%), an average specificity of 92.2% (95% CI, 89.5%-94.9%), an average positive predictive value of 88% (95% CI, 83.3%-91.5%), and an average negative predictive value of 93.5% (95% CI, 90.9%-96%). Interobserver agreement was high on a per-polyp basis (kappa statistic range, .61-.74) and high to excellent on a per-patient basis (kappa statistic range, .79-.91). CONCLUSIONS: Low-dose multidetector CTC without cathartic preparation compares favorably with colonoscopy for the detection of colorectal polyps.

Adult↗

Detection of colorectal lesions with virtual computed tomographic colonography.

BACKGROUND: The aim of our study was to compare the performance of virtual computed tomographic colonography with that of conventional colonoscopy in a blinded, prospective study in 165 patients with suspected colorectal lesions. METHODS: There were 165 patients, all referred for conventional colonoscopy, who underwent preliminary virtual computed tomographic colonography. Computed tomograhic images of all suspected lesions were analyzed and subsequently compared with conventional colonoscopy findings. RESULTS: There were 30 colorectal cancers and 37 polyps identified at conventional colonoscopy. Virtual computed tomographic colonography correctly detected all cancers, as well as 11 of 12 polyps of 10 mm in diameter or larger (sensitivity, 92%); 14 of 17 polyps between 6 and 9 mm (sensitivity, 82%); and 4 of 8 polyps of 5 mm or smaller (sensitivity, 50%). The per-patient sensitivity and specificity were 92% and 97%, respectively. CONCLUSIONS: Virtual computed tomographic colonography has a diagnostic sensitivity similar to that of conventional colonoscopy for the detection of colorectal lesions larger than 6 mm in diameter.

Adult↗

Hepatocyte ultrastructural aspects after preoperative biliary drainage in pancreatic cancer patients with cholestatic jaundice.

BACKGROUND: The usefulness of preoperative biliary drainage in long-standing obstructive jaundice remains controversial. This study was designed to assess microscopic and ultrastructural changes in the morphology of hepatocytes from patients with obstructive jaundice treated with biliary drainage for 14 days. PATIENTS AND METHODS: In 8 patients with jaundice due to pancreatic neoplasms we obtained two fine-needle liver biopsies: the first during a transhepatic cholangiographic examination before placing preoperative drainage and the second at surgery, on day 14 of drainage. Biopsy samples were examined by light and electron microscopy and correlated to serum liver functional tests recorded before and after biliary drainage. RESULTS: Pre-drainage biopsy presented diffuse morphological signs of congestion and cholestasis, lipid and bilirubin cytoplasm inclusions, loss of bile canaliculi microvilli and diffuse bile canaliculi dilatation. After-drainage biopsies presented reduction of bile canaliculi dilatation, partial restoring of bile canaliculi microvilli and persistence of diffuse hepatocyte structural and ultrastructural changes. Patients' laboratory values (bilirubin, alkaline phosphatase, SGGT, SGOT and SGPT), that were significantly impaired before drainage, returned almost to normal within two weeks after drainage. CONCLUSION: Preoperative biliary drainage in patients with long-standing obstructive jaundice has received wide yet controversial support due to a well established pathophysiological background. The present findings of scarce recovery of hepatocyte changes after 14 days' drainage seemingly question its appropriateness.

Aged↗

Palliative management of malignant rectosigmoidal obstruction. Colostomy vs. endoscopic stenting. A randomized prospective trial.

BACKGROUND: Colostomy was the palliative treatment of choice in patients with malignant unresectable rectosigmoid obstruction. Palliative endoscopic treatment of malignant rectosigmoid obstruction by endoluminal self-expanding metallic stents is nowadays a well-established procedure. PATIENTS AND METHODS: Twenty-two patients, referred for treatment with diagnosis of malignant obstruction of the rectosigmoid region presenting an advanced unresectable stage, were enrolled. Patients were randomly assigned into two treatment groups (endoscopic stenting vs colostomy) according to random-number tables. The length of procedure, morbidity and mortality rate, canalization of the gastrointestinal tract, restoration of oral intake and hospital stay were assessed. RESULTS: Endoscopic group: The median length of procedure was 36 minutes. No death was observed. None of the patients reported complications. All patients resumed bowel function within 24 hours. The restoration of oral intake was achieved one day after stent placement. The median hospital stay was 2.6 days. Colostomy group: The median length of the operation was 75.4 minutes. No mortality was reported. In 1 patient (9.1%) stoma prolapse was observed 3 days after the operation. Canalization of the gastrointestinal tract was restored when colostomy was opened (on postoperative day 3). All patients were able to resume oral feedings on postoperative day 3. The median hospital stay was 8.1 days. CONCLUSION: There were no statistically significant differences between the 2 groups concerning morbidity and mortality. Endoscopic stenting was significantly more effective concerning operative time, restoration of bowel function and oral intake and median hospitalization. Our results would suggest that endoscopically placed metal stents offer an effective alternative to surgical palliation in patients suffering from unresectable malignant rectosigmoid obstruction.

Aged↗

Palliative management of malignant antro-pyloric strictures. Gastroenterostomy vs. endoscopic stenting. A randomized prospective trial.

BACKGROUND: Gastroenterostomy was the palliative treatment of choice in patients with malignant unresectable gastric outlet obstruction. Palliative endoscopic treatment of malignant gastric outlet obstruction with endoluminal self-expanding metallic stents is nowadays a well-established procedure. PATIENTS AND METHODS: Eighteen patients referred for treatment with diagnosis of malignant strictures of the antro-pyloric tract presenting at an advanced unresectable stage. The patients were randomly assigned into two treatment groups (endoscopic vs. surgery) according to random-number tables. The length of procedure, morbidity and mortality rate, restoration of oral intake and gastric emptying at 8, 15 days and 3 months from treatment and hospital stay were assessed. RESULTS: Endoscopic group: The median length of procedure was 40 minutes. No death and one minor complication (11.1%) was reported. Mean time for oral intake was 2.1 days. Gastric emptying was satisfactory in 88.9% after 8 days and in 100% of patients after 15 days and 3 months. The median hospital stay was 3.1 days. Surgery group: The median length of the operation was 93 minutes. No mortality was reported. One patient (11.1%) developed anastomotic bleeding which required relaparotomy. Mean time for oral intake was 6.3 days. Gastric emptying was satisfactory in 66.7% of patients after 8 days, in 88.9% after 15 days and in 100% after 3 months. The median hospital stay was 10 days. CONCLUSION: There were no statistically significant differences between the 2 groups even with respect to morbidity, mortality, delayed gastric emptying and clinical outcomes at 3-month follow-up. Endoscopic stenting was significantly more effective with respect to operative time, restoration of oral intake and median hospitalization. Our results would suggest that endoscopically placed metal stents offer an effective alternative to surgical palliation in patients with unresectable malignant strictures.

Aged↗

Malignant intestinal obstruction: useful technical advice in self-expanding metallic stent placement.

BACKGROUND: The use of endoluminal self-expanding metallic stents is an effective alternative to surgery in neoplastic gastrointestinal tract obstructions. It is often difficult to mark the proximal segment of the stricture under fluoroscopic guidance (due to patient movements or change of markers' position). PATIENTS AND METHODS: We placed Ultraflex precision colonic stent (Microvasive, Boston Scientific) in ten patients with neoplastic stricture of the rectosigmoid colon. Before placement of the delivery catheter, a radiopaque proximal marker was identified on the delivery catheter under fluoroscopic guidance. The external side of the delivery catheter was coloured (in correspondence with the radiopaque marker) with non toxic colour. After the introduction of the delivery catheter, we placed the proximal coloured marker just above the distal tumour margin under endoscopic guidance. RESULTS: The procedure was successful in relieving the obstruction in all patients, without mortality or complications. In all patients the coloured marker was identified and the stent correctly placed. CONCLUSION: The location of a coloured marker in the external side of the delivery catheter permits an accurate and correct placement of the stent, without unnecessary exposure to X-rays.

Catheterization↗