PubMed Health⌕ Search

Biomedical subjects

Alejandro Nieponice

Publications and source records attributed to Alejandro Nieponice.

7 recordsLinked to original sources

Mechanical stimulation induces morphological and phenotypic changes in bone marrow-derived progenitor cells within a three-dimensional fibrin matrix.

One of the major limitations in tissue engineering is cell sourcing. Multipotent progenitor cells appear to have many promising features for that purpose. Mechanical stimulation is known to play an important role in determining cell phenotype. The aim of this work was to investigate the effects of cyclic stretch on rat bone marrow derived progenitor cell (BMPC) morphology and smooth muscle-directed differentiation within a three-dimensional fibrin matrix. BMPCs were suspended in a fibrin gel, pipetted into the trough of Flexcell Tissue-Train plates, and stimulated with 10% longitudinal cyclic stretch at 1 Hz for 6 days. Unconstrained (stress- and strain-free) and static anchored (constrained but not stretched) samples were used as controls. Stress filament area per cell was increased in the stretched samples compared to static anchored and free-float controls. Cells in the free float controls were randomly aligned, while they aligned parallel to the direction of the stress or strain in the other groups. Immunofluorescence suggested an increased expression of smooth muscle markers (smooth muscle alpha actin and h1-calponin) in both stretched and constrained control samples, but not in unconstrained controls. Qualitative assessment suggested that collagen production was increased in both mechanically stimulated samples. Proliferation was inhibited in stretched samples compared to the constrained controls. This work suggests an ability of rat BMPCs to differentiate toward a smooth-muscle-cell-like lineage when exposed to biomechanical stimulation in a three-dimensional model. The observation that the constrained samples induced changes in BMPCs suggests that stress alone may be stimulatory, but addition of cyclic stretch appears to augment the responses.

Animals↗

A new experimental system for the extended application of cyclic hydrostatic pressure to cell culture.

Mechanical forces have been shown to be important stimuli for the determination and maintenance of cellular phenotype and function. Many cells are constantly exposed in vivo to cyclic pressure, shear stress, and/or strain. Therefore, the ability to study the effects of these stimuli in vitro is important for understanding how they contribute to both normal and pathologic states. While there exist commercial as well as custom-built devices for the extended application of cyclic strain and shear stress, very few cyclic pressure systems have been reported to apply stimulation longer than 48 h. However, pertinent responses of cells to mechanical stimulation may occur later than this. To address this limitation, we have designed a new cyclic hydrostatic pressure system based upon the following design variables: minimal size, stability of pressure and humidity, maximal accessibility, and versatility. Computational fluid dynamics (CFD) was utilized to predict the pressure and potential shear stress within the chamber during the first half of a 1.0 Hz duty cycle. To biologically validate our system, we tested the response of bone marrow progenitor cells (BMPCs) from Sprague Dawley rats to a cyclic pressure stimulation of 120/80 mm Hg, 1.0 Hz for 7 days. Cellular morphology was measured using Scion Image, and cellular proliferation was measured by counting nuclei in ten fields of view. CFD results showed a constant pressure across the length of the chamber and no shear stress developed at the base of the chamber where the cells are cultured. BMPCs from Sprague Dawley rats demonstrated a significant change in morphology versus controls by reducing their size and adopting a more rounded morphology. Furthermore, these cells increased their proliferation under cyclic hydrostatic pressure. We have demonstrated that our system imparts a single mechanical stimulus of cyclic hydrostatic pressure and is capable of at least 7 days of continuous operation without affecting cellular viability. Furthermore, we have shown for the first time that BMPCs respond to cyclic hydrostatic pressure by alterations in morphology and increased proliferation.

Animals↗

A seeding device for tissue engineered tubular structures.

One of the challenges in the tissue engineering of tubular tissues and organs is the efficient seeding of porous scaffolds with the desired cell type and density in a short period of time, without affecting cell viability. Though different seeding techniques have been investigated, a fast, reproducible, and efficient bulk seeding method with uniform cellular distribution has yet to be reported. In this paper, a novel seeding device utilizing the synergistic effects of vacuum, centrifugal force and flow has been developed and analyzed. The device allows porous tubular scaffolds to be uniformly bulk seeded as well as luminally surface-seeded with cells. Porous tubular polymer scaffolds were bulk and surface-seeded with cell suspensions, and cell viability and seeding efficiency were subsequently assessed. A rigorous quantitative analysis of shear stresses acting on the cells during the seeding process, and of cell location within the scaffolds following seeding was also performed. Our results showed that the scaffolds were uniformly seeded along the longitudinal and circumferential directions within the tube wall without affecting cell viability or exposing them to excessive shear stresses.

Animals↗

Reinforcement of esophageal anastomoses with an extracellular matrix scaffold in a canine model.

BACKGROUND: The gastric pull-up procedure, a standard intervention after radical esophagectomy, is associated with high morbidity and mortality due to leaks and stricture. A previous preclinical study showed that an extracellular matrix (ECM) scaffold with autologous muscle tissue could be used to repair a complete circumferential defect in the cervical esophagus. The aim of the present study was to determine if healing of end-to-end anastomoses of the esophagus could be improved by reinforcement with an ECM scaffold. METHODS: Twelve female mongrel dogs underwent a complete transection of either the cervical esophagus (n = 6) or the gastroesophageal junction (n = 6). A portion of the endomucosa at the anastomotic site was resected and replaced with an ECM scaffold in contact with the subjacent muscle and the muscle was anastomosed. The measured end points included macroscopic and microscopic evaluation and quantification of the esophageal diameter at the anastomotic site. RESULTS: No anastomotic leaks or systemic complications were observed in the ECM-treated animals. Morphologic findings in both groups showed complete mucosal covering of the surgery site. The remodeled esophageal tissue showed angiogenesis and complete epithelialization. Intact, organized layers of muscle tissue were present between the native muscularis externa and the submucosal layer and effectively bridged the transected ends. CONCLUSIONS: The ECM scaffold altered the default mechanism of esophageal repair. Scar tissue formation with associated stricture was virtually eliminated, and the esophageal healing response was characterized by the replacement with structurally normal tissue layers. These findings suggest that the high morbidity rate associated with esophagectomy procedures may be reduced by this ECM augmentation procedure at the anastomotic site.

Anastomosis, Surgical↗

Molecular aspects of vascular tissue engineering.

Cardiovascular disease remains the number one cause of death in the United States. Most current surgical procedures to alleviate this disease rely on the availability of suitable small diameter vascular grafts, which are constrained by several limitations. Tissue engineering brings new hope to this field, but still faces many challenges. This review focuses on the molecular aspects of the different components of vascular tissue engineering. The topics addressed include the cell type, extracellular matrix, and physical and biochemical stimulation with respect to their role in the development of a tissue engineered vascular graft.

Animals↗

Esophageal reconstruction with ECM and muscle tissue in a dog model.

An in vivo study was conducted to determine if an extracellular matrix (ECM) scaffold co-localized with autologous muscle tissue could achieve constructive remodeling of esophageal tissue without stricture. ECM derived from the porcine urinary bladder was processed, decellularized, configured into a tube shape, and terminally sterilized for use as a bioscaffold for esophageal reconstruction in a dog model. Twenty-two dogs were divided into four groups, three groups of five and one group of seven. Groups 1 and 2 were repaired with either ECM alone or muscle tissue alone, respectively. Groups 3 and 4 were repaired with ECM plus either a partial (30%) covering with muscle tissue or a complete (100%) covering with muscle tissue, respectively. Animals in groups 1 and 2 were sacrificed within approximately 3 weeks because of the formation of intractable esophageal stricture. Four of five dogs in group 3 and six of seven dogs in group 4 were survived for 26 days to 230 days and showed constructive remodeling of esophageal tissue with the formation of well organized esophageal tissue layers, minimal stricture, esophageal motility, and a normal clinical outcome. Mechanical testing of a subset of the remodeled esophageal tissue from animals in groups 3 and 4 showed progressive remodeling from a relatively stiff, non-compliant ECM tube structure toward a tissue with near normal biomechanical properties. We conclude that ECM bioscaffolds plus autologous muscle tissue, but not ECM scaffolds or muscle tissue alone, can facilitate the in situ reconstitution of structurally and functionally acceptable esophageal tissue.

Animals↗

Peptidergic innervation of blood vessels and interstitial cells in the testis of the cat.

We studied the innervation of the cat testis using a panel of antisera against the following neuronal markers: protein gene product 9.5 (PGP), neuropeptide Y, C-terminal peptide of neuropeptide Y, galanin, vasoactive intestinal peptide (VIP), calcitonin gene-related peptide, and substance P. Immunoreactivity against PGP, a general neuronal label, demonstrated the arrangement of fibers from the superior spermatic nerve (SSN) in the testicular pedicle and the cephalic testicular pole, and those of the inferior spermatic nerve (ISN) along the vas deferens and the inferior testicular ligament. The testicular parenchyma exhibited a very rich innervation, mainly distributed to blood vessels and Leydig cell nests, but also in close association with seminiferous tubules. Numerous peptidergic fibers were present in the SSN and ISN, albeit in different proportions. Thus, VIP-immunoreactive fibers were almost absent in the SSN, but were the most abundant subpopulation of the ISN. The testicular interstitium contained numerous peptidergic fibers, associated with blood vessels, interstitial Leydig cells, and seminiferous tubules. Similar fibers were related to the rete testis. Parenchymatous VIP-immunoreactive nerves disappeared after bilateral vasectomy. Stimulation of the ISN under experimental conditions was associated with an increase of blood flow, and induced a large release of VIP into the spermatic vein. The extensive and selective distribution of nerve fibers within the cat testicular parenchyma supports the importance of spermatic nerves for testicular function. Furthermore, the differences in the fiber composition of the SSN and ISN can be correlated with their opposing effects on testosterone secretion and testicular blood flow.

Animals↗