PubMed Health⌕ Search

Biomedical subjects

Alejandro Peregrina

Publications and source records attributed to Alejandro Peregrina.

2 recordsLinked to original sources

Anterior deprogramming device fabrication using a thermoplastic material.

This article presents a simple and efficient technique to fabricate an anterior deprogramming device using a thermoplastic material. The material, softened by heating, is adapted to the maxillary incisors while moldable. The operator guides the mandible into closure as the material stiffens. The device is then trimmed, and a posterior centric relation record is made using the recording material of choice.

Centric Relation↗

Effect of two types of latex gloves and surfactants on polymerization inhibition of three polyvinylsiloxane impression materials.

STATEMENT OF PROBLEM: Polymerization inhibition of polyvinylsiloxane impression materials has been reported when in sustained contact with some types of latex gloves. PURPOSE: This study examined the polymerization inhibition of 3 polyvinylsiloxane impression materials placed in contact with surfaces subjected to prior contact with gloves or commonly used surfactants. MATERIAL AND METHODS: A 2 x 3 x 4 x 2 design was used (n = 20), with 2 types of gloves (powdered and unpowdered), 3 types of polyvinylsiloxane impression materials (Aquasil, Extrude, and Affinis), 4 surfactant conditions (water, soap/water-rinse, alcohol, and unexposed), and 2 ambient temperatures of 22 degrees C and 36 degrees C. After glove exposure to surfactants, a glass surface was subjected to rubbing contact with the treated glove for a standardized time. After drying, automixed polyvinylsiloxane impression materials were dispensed onto the treated surface. Specimens were removed and evaluated for polymerization inhibition at the manufacturer's recommended polymerization time (36 degrees C), or after 15 minutes at 22 degrees C. Specimens were rated as polymerized, or as inhibited if any polyvinylsiloxane residue remained on the slab. A chi-square analysis was used to evaluate the results (alpha=.05). RESULTS: Setting inhibition was found only with one of the polyvinylsiloxane materials when alcohol was used as a surfactant. At 22 degrees C, the inhibition rate ranged from 95% to 100% for both glove types; at 36 degrees C inhibition ranged from 40% (unpowdered gloves) to 75% (powdered gloves), respectively. CONCLUSION: Under these in vitro conditions, glove exposure to alcohol resulted in polymerization inhibition of 1 of 3 tested polyvinylsiloxane impression materials (Extrude).

Alcohols↗