Inter-pulse interval between rectangular voltage pulses affects electroporation threshold of artificial lipid bilayers.

This paper describes experiments that determine how the inter-pulse interval between rectangular pulses in a train of pulses alters the threshold of electroporation of 1-pamitoyl 2-oleoyl phosphatidycholine bilayer lipid membranes. The bilayers were exposed to a train of sixteen 100-micros duration pulses. Threshold voltage and the sequence number of the pulse in the train, where onset of the electroporation occurred, were recorded for six inter-pulse intervals (infinity, 1000 micros, 100 micros, 10 micros, 1 micros, 0 micros). The threshold voltage of the pulse train decreased linearly with the logarithm of the inter-pulse interval. When the inter-pulse interval was 1 microm, electroporation threshold dropped to that of a single pulse with duration 1600 micros (equal to the sum of all pulse durations in the train). In this case, the occurrence of bilayer rupture was almost equally frequent for all pulses in the train. When the inter-pulse interval between the pulses exceeded 1 micros, the influence of the previous pulse on the response to the following pulse declined. It became more likely that the bilayer ruptured during the first half of the train. These experimental observations suggest that a train of pulses applied with short inter-pulse interval (less than 1 ms) can lower the electroporation threshold of bilayer lipid membranes.

Dose-Response Relationship, Drug↗

Optimisation of pulse parameters in vitro for in vivo electrochemotherapy.

The aim of our study was to optimise electric pulse parameters for electrochemotherapy by sampling the space of pulse parameter variables using systematic in vitro experiments. For this purpose we defined parameters that describe the effectiveness of different sets of electric pulse parameters in vitro and combined them into an objective function that characterises requirements for successful electrochemotherapy. The objective function values were calculated for all the sets of electric pulse parameters included in in vitro experiments. Similar values were grouped together by hierarchical clustering. The 'electrochemotherapeutic' effectiveness of two sets of pulse parameters (8 pulses, 100 micros, 1 Hz and 1 pulse, 1000 micros, 1 Hz), which belong to the most efficient cluster, and one set of pulse parameters (16 pulses, 20 ms, 1 Hz), which belongs to the least efficient cluster, was tested in vivo on a murine tumor model. The sets of pulse parameters from the most efficient cluster had comparable effects in vivo, while the electrochemotherapy with the set of pulse parameters from the least efficient cluster was less effective. Our results demonstrated that electric pulse parameters for effective in vivo application can be determined from in vitro experiments considering application specifications.

Animals↗