PubMed Health⌕ Search

Biomedical subjects

Ales Strancar

Publications and source records attributed to Ales Strancar.

At least 19 recordsLinked to original sources

Chemical and chromatographic stability of methacrylate-based monolithic columns.

Chemical and chromatographic stability of methacrylate-based monolithic columns bearing 3-N,N-diethylamino-2-hydroxypropyl (DEAE) and quarternary amine (QA) groups was studied. The leakage products from both monolithic columns were determined and the leakage of amines has been quantified in alkali solutions. Monolithic columns bearing QA functional groups being exposed to 1M sodium hydroxide solution for up to 3 months caused reduction of ion-exchange groups for approximately 12%, while for DEAE monolithic columns was only around 3% in 1 year. In 0.1M NaOH and 20% ethanol degradation was significantly lower. The main leaking compound from DEAE monolith was found to be 3-(diethylamino)-1,2-propanediol and 2,3-dihydroxypropyltrimethylammonium salt for QA monolith. During repeated 50 cleaning-in-place (CIP) cycles, no changes in chromatographic properties were detected.

Chromatography, Ion Exchange↗

Determination of DNA entrapment into liposomes using short monolithic columns.

A high-performance liquid chromatography (HPLC) method for the determination of DNA entrapment efficiency in liposomes has been developed. Plasmid DNA was encapsulated into positively charged liposomes. Non-entrapped DNA was separated by ultracentrifugation from liposomes and supernatant was chromatographed on Convective Interaction Media (CIM) DEAE disk. The elution of DNA was monitored by the absorbance at 260 nm and the quantity of DNA in the tested sample was calculated from the integrated peak areas using the appropriate standard curve. This method is fast, simple, precise and does not require any kind of DNA labelling in contrast with mostly used methods for determination of DNA entrapment efficiency.

Chromatography, High Pressure Liquid↗

Short monolithic columns--a breakthrough in purification and fast quantification of tomato mosaic virus.

Drawbacks of conventional virus purification methods have led to the development of new, mostly chromatography-based methods. Short monolithic columns are stationary phases intended for purification of large molecules. In this work efficient chromatographic purification of tomato mosaic virus (ToMV) from plant material is described. Based on short monolithic column, the purification process was shortened from 5 days to 2 hours. High viral purity was achieved and recovery of chromatographic step was up to 90%. In addition, these columns enabled preliminary quantification of the virus in just a few minutes, much faster than other quantification methods (e.g. enzyme-linked immunosorbent assay or real-time polymerase chain reaction) which take 1-2 days. These results demonstrate the potential of short monolith column technology for purification and analysis of different viruses.

Chromatography, Ion Exchange↗

Anion-exchange chromatography using short monolithic columns as a complementary technique for human serum albumin depletion prior to human plasma proteome analysis.

In order to enable the detection of low abundance proteins from human plasma, it is necessary to remove high abundance proteins. Among them, human serum albumin and immunoglobulin G represent more than 75% of all such proteins. In this paper, the characterization of short monolithic columns was performed followed by the optimization of a multidimensional approach, known as conjoint liquid chromatography, to deplete human serum albumin and immunoglobulin G from a human plasma sample. Two different chromatographic modes were used: ion-exchange chromatography and affinity chromatography. A monolithic stationary phase (convective interaction media disk) bearing strong anion-exchange groups and another immobilized with protein G were placed in series into one housing. The optimal binding conditions were found that removed a majority of human serum albumin and immunoglobulin G from the human plasma sample. This method was compared to the depletion using a combination of pseudo-affinity and affinity columns. The results of the human serum albumin and immunoglobulin G depletion were confirmed by 2D electrophoresis. It has been shown that anion-exchange and affinity chromatography using convective interaction media monolithic columns can represent an efficient complementary technique for human serum albumin and immunoglobulin G removal from human plasma.

Biomarkers↗

Immobilization of deoxyribonuclease via epoxy groups of methacrylate monoliths. Use of deoxyribonuclease bioreactor in reverse transcription-polymerase chain reaction.

A deoxyribonuclease bioreactor was prepared by immobilization of deoxyribonuclease I through epoxy groups inherently present on poly (glycidyl methacrylate-co-ethylene dimethacrylate) monoliths. Columns with various levels of DNase activity were prepared varying immobilization temperature, pH, time and method. The apparent Michaelis-Menten constant, Km(app), and turnover number, k3app, for immobilized DNase determined by on-line frontal analysis method were, respectively, 0.28 g of DNA l(-1) and 16 dA260nm min(-1) mg(-1) of immobilized DNase. The highest activity of immobilized DNase was detected at 1 mM calcium ions concentration and mirrored properties of free enzyme; however, reaction temperature in the range from 25 to 37 degrees C has no significant effect on activity of immobilized DNase in contrary to free enzyme. The CIM DNase bioreactor was used for elimination of DNA contaminants in RNA samples prior to reverse transcription followed by PCR.

Base Sequence↗

Purification of genomic DNA by short monolithic columns.

The isolation and purification of nucleic acids is essential for many procedures in molecular biology. After showing that bacterial and eukaryotic genomic DNA can be specifically bound to the CIM DEAE monolithic column, this characteristic was exploited in development of a simple and fast chromatographic procedure for isolation and purification of genomic DNA from cell lysates that does not include the usage of toxic organic solutions. The purity and the quality of the isolate as well as the duration of the procedure was similar to other chromatographic methods used today for isolation of genomic DNA, but the initial sample volume was not restricted.

Chromatography, Ion Exchange↗

Simple method for determining the amount of ion-exchange groups on chromatographic supports.

The objective of this study was to develop a fast, simple, non-destructive, non-toxic and low-priced method for determining the amount of ionic groups on resins, since the conventional titration method fails to give proper results on methacrylate monoliths. After the column had been pre-saturated with a high concentration buffer solution, a low concentration buffer solution of the same pH value was pumped through the column. Measuring pH and absorbance, the profiles with a shape of typical break-through curve were obtained. It was shown that the time of the pH transient, which appeared under such conditions, could be used as a measure of the total ionic capacity of ion-exchange monolithic columns. The effect of the column length, linear velocity and varying concentrations of buffer solutions on the time of the pH transient was examined. The method was shown to be suitable for determining the amount of ionic groups on both anion and cation monolithic columns. In addition, it could also be applied to particle bed columns. The time of the pH transient and the protein dynamic binding capacity were also compared and it was concluded that for a given monolith the protein capacity can be derived from the data obtained by the new method.

Chromatography, Ion Exchange↗

Effect of the glass surface modification on the strength of methacrylate monolith attachment.

The influence of glass surface modification in order to determine strength of the monolith attachment was studied. Modification consists of pre-treatment of the glass with chemicals or boiling in deionized water, silanization and drying has been investigated on different types of glass. Amount of silane groups was determined by measurement of the contact angle between the glass surface and water drop. The highest values were found for soda-lime glass. Strength of the monolith attachment was established by pumping ethanol through the monolithic capillaries and measuring the pressure drop at which monolith was dislodged. Surprisingly, it was found that the critical part of the glass surface modification procedure is glass pre-treatment. Good results were obtained with glass boiled in water for 2.5 h or more.

Glass↗

Application of monoliths for plasmid DNA purification development and transfer to production.

The demand of high-purity plasmid DNA (pDNA) for gene-therapy and genetic vaccination is still increasing. For the large scale production of pharmaceutical grade plasmids generic and economic purification processes are needed. Most of the current processes for pDNA production use at least one chromatography step, which always constitutes as the key-step in the purification sequence. Monolithic chromatographic supports are an alternative to conventional supports due to their excellent mass transfer properties and their high binding capacity for pDNA. Anion-exchange chromatography is the most popular chromatography method for plasmid separation, since polynucleotides are negatively charged independent of the buffer conditions. For the implementation of a monolith-based anion exchange step into a pDNA purification process detailed screening experiments were performed. These studies included supports, ligand-types and ligand-densities and optimization of resolution and productivity. For this purpose model plasmids with a size of 4.3 and 6.9 kilo base pairs (kbp) were used. It could be shown, that up-scaling to the production scale using 800 ml CIM Convective Interaction Media radial flow monoliths is possible under low pressure conditions. CIM DEAE was successfully implemented as intermediate step of the cGMP pDNA manufacturing process. Starting from 2001 fermentation aliquots pilot scale purification runs were performed in order to prove scale-up and to predict further up-scaling to 8 1 tube monolithic columns. The analytical results obtained from these runs confirmed suitability for pharmaceutical applications.

Chromatography, Ion Exchange↗

Chromatographic detection of residual cellular DNA on short monolithic columns.

Analysis of crude samples from biotechnological processes is often required to demonstrate that residual host cell impurities are reduced or eliminated during purification. Current knowledge suggests that a continuous-cell-line DNA can be considered a cellular contaminant rather than a significant risk factor requiring removal to extremely low levels. Anion-exchange chromatography is one of the most important methods used in the downstream processing and analysis of different biomolecules. In this article, an application using Convective Interaction Media monolithic columns to improve the detection of residual cellular DNA is described.

Cell Line↗

Convective interaction media short monolithic columns: enabling chromatographic supports for the separation and purification of large biomolecules.

New therapeutics that are being developed rely more and more on large and complex biomacromolecules like proteins, DNA, and viral particles. Manufacturing processes are being redesigned and optimized both upstream and downstream to cope with the ever-increasing demand for the above target molecules. In downstream processing, LC still represents the most powerful technique for achieving high yield and high purities of these molecules. In most cases, however, the separation technology relies on conventional particle-based technology, which has been optimized for the purification of smaller molecules. New technologies are, therefore, needed in order to push the downstream processing ahead and into the direction that will provide robust, productive, and easy to implement methods for the production of novel therapeutics. New technologies include the renaissance of membranes, various improvements of existing technologies, but also the introduction of a novel concept--the continuous bed or monolithic stationary phases. Among different introduced products, Convective Interaction Media short monolithic columns (SMC) that are based on methacrylate monoliths exhibit some interesting features that make them attractive for these tasks. SMC can be initially used for fast method development on the laboratory scale and subsequently efficiently transferred to preparative and even more importantly to industrial scale. A brief historical overview of methacrylate monoliths is presented, followed by a short presentation of theoretical considerations that had led to the development of SMC. The design of these columns, as well as their scale-up to large units, together with the methods for transferring gradient separations from one scale to another are addressed. Noninvasive methods that have been developed for the physical characterization of various batches of SMC, which fulfill the regulatory requirements for cGMP production, are discussed. The applications of SMC for the separation and purification of large biomolecules, which demonstrate the full potential of this novel technology for an efficient downstream processing of biomolecules, are also presented.

Biopolymers↗

Convective Interaction Media (CIM)--short layer monolithic chromatographic stationary phases.

Modern downstream processing requires fast and highly effective methods to obtain large quantities of highly pure substances. Commonly applied method for this purpose is chromatography. However, its main drawback is its throughput since purification, especially of large molecules, requires long process time. To overcome this problem several new stationary phases were introduced, among which short layer monoliths show superior properties for many applications. The purpose of this review is to give an overview about short methacrylate monolithic columns commercialised under the trademark Convective Interaction Media (CIM). Their unique properties are described from different perspectives, explaining reasons for their application on various areas. Approaches to prepare large volume methacrylate monolithic column are discussed and optimal solutions are given. Different examples of CIM monolithic column implementation are summarised in the last part of the article to give the reader an idea about their advantages.

Algorithms↗

Concentration of plant viruses using monolithic chromatographic supports.

A new chromatographic medium, Convective Interaction Media(CIM) disk monolithic columns, was applied to plant virus concentration. The ability of the columns to concentrate highly diluted plant viruses was tested on a model plant virus, rod-shaped tomato mosaic virus (ToMV). Enzyme-linked immunosorbent assay (ELISA) was used for the quantitative analysis. The virus was concentrated using a strong anion exchanger, CIM quaternary amine (QA) disk monolithic column. A high salt concentration was used to elute the concentrated virus from the columns. It has been demonstrated that ToMV, which had been diluted considerably below the sensitivity of ELISA, was concentrated by several orders of magnitude in the one-step procedure. Concentrated virus preparations could be used directly for ELISA testing. In comparison with methods described for concentrating plant viruses from irrigation water, the above procedure may provide a much faster and more efficient way to concentrate highly diluted plant viruses. The procedure could be applied to the testing of other highly diluted plant viruses, and to concentrating viruses for antiserum production.

Anion Exchange Resins↗

Application of short monolithic columns for fast purification of plasmid DNA.

Anion-exchange chromatography is one of the most important methods in downstream processing of plasmid DNA, both as a process and as an analytical technique. Separation of plasmid DNA on traditional particle-based anion-exchange supports is usually slow. Moreover, such supports have a low capacity for plasmid DNA due to the steric exclusion effects. In this work, the separation of plasmid DNA using short monolithic columns, Convective Interaction Media, will be presented. It will be demonstrated that plasmid DNA can be purified from bacterial cells using alkaline lysis followed by chromatography on a very short weak anion-exchange chromatographic columns-disks-with good purity and quality within a short time. Furthermore, the separation of plasmid DNA from cell RNA can be carried out without the need of adding RNAse. Fast and efficient method for in-process control of the purified plasmid will be described as well.

Anions↗

Characterization of methacrylate monoliths for purification of DNA molecules.

The suitability of methacrylate based anion exchange monolithic supports for the separation and purification of plasmid and genomic DNA has been explored. The effect of the size of the channels, ionic strength of the solution, and ligand density on the dynamic binding capacity has been investigated. The dynamic binding capacity was found to be flow independent, at least up to a linear velocity of 700 cm h(-1), and exceeded 9 mg mL(-1) for all types of DNA. The recovery depends on the pH value of the mobile phase and its ionic strength as well as on the density of the active groups. Under optimal conditions recoveries exceeding 80% were obtained even for genomic DNA. Finally, the suitability of this approach is demonstrated by purification of a real-life sample.

Aspergillus niger↗

Enzyme immobilization on epoxy- and 1,1'-carbonyldiimidazole-activated methacrylate-based monoliths.

Monolithic Convective Interaction Media (CIM) have been activated with epoxide and imidazole carbamate functionalities and used as supports for covalent immobilization of protein A, deoxyribonuclease I, and trypsin. The efficiency of immobilization for these proteins was determined from the amount of bound IgG, degradation of DNA, and hydrolysis of Nalpha-benzoyl-L-arginine ethyl ester, respectively. The respective biological activities of trypsin and the binding capacity of protein A immobilized via imidazole carbamate groups were 11.45 and 2.25 times higher than those obtained for epoxide matrix while they were practically equal for deoxyribonuclease I. The kinetics of immobilization was studied in detail for trypsin under dynamic conditions and revealed that the enzyme immobilized via imidazole carbamate groups already reached its highest activity in 5 min. In contrast, a much longer time was required for immobilization via epoxy groups.

Animals↗

Characterization of CIM monoliths as enzyme reactors.

The immobilization of the enzymes citrate lyase, malate dehydrogenase, isocitrate dehydrogenase and lactate dehydrogenase to CIM monolithic supports was performed. The long-term stability, reproducibility, and linear response range of the immobilized enzyme reactors were investigated along with the determination of the kinetic behavior of the enzymes immobilized on the CIM monoliths. The Michaelis-Menten constant K(m) and the turnover number k(3) of the immobilized enzymes were found to be flow-unaffected. Furthermore, the K(m) values of the soluble and immobilized enzyme were found to be comparable. Both facts indicate the absence of a diffusional limitation in immobilized CIM enzyme reactors.

Enzymes, Immobilized↗

Application of short monolithic columns for improved detection of viruses.

Monolithic chromatography media represent a novel generation of stationary phases introduced in the last 10-15 years providing a chromatography matrix with enhanced mass transfer and hydrodynamic properties. These features allow for an efficient and fast separation of especially large biomolecules like e.g., DNA and viruses. In this study, the enrichment of virus RNA on short monolithic columns prior to molecular detection of viruses is described. Measles and mumps viruses were chosen as model viruses. The results show that it is possible to bind viral RNA on monoliths and concentrate viral nucleic acids from a fairly dilute sample. Consequently, a potential application of short monolithic columns is the concentration of virus RNA to improve the sensitivity and selectivity of viral detection with the possibility of isolating viral RNA from cell-free biological fluids.

Chromatography, DEAE-Cellulose↗