PubMed Health⌕ Search

Biomedical subjects

Alessandro Della Corte

Publications and source records attributed to Alessandro Della Corte.

25 records · Page 2Linked to original sources

Improvement in accuracy of diagnosis of carotid artery stenosis with duplex ultrasound scanning with combined use of linear array 7.5 MHz and convex array 3.5 MHz probes: validation versus 489 arteriographic procedures.

OBJECTIVE: Validity of a method to improve the accuracy of carotid artery duplex scanning was tested in comparison with arteriography. STUDY DESIGN: In 489 patients who had not previously undergone arteriography, 978 carotid arteries were examined with duplex ultrasound scanning. In method A, a linear array 7.5 MHz transducer with pulsed-wave 4.7 MHz Doppler scanning was used. For the diagnosis and grading of carotid stenosis, peak systolic and end-diastolic velocity of the Doppler waves were recorded. Method B consisted of complete ultrasound imaging and color-flow mapping with a convex array 3.5 MHz transducer with pulsed-wave 2.8 MHz Doppler scanning in all patients who had previously undergone method A. Further velocity measurements were performed at the sites of stenosis. The results of methods A and B were compared with data from neurologic assessment and arteriographic studies. RESULTS: Method B showed significantly higher diagnostic agreement with arteriography than did method A (K 95% confidence interval [CI], 0.87-0.93 vs 0.79-0.85; P <.05), and the number of mistakes in grading stenosis was significantly lower (primarily because of decreased overestimation) in patients with internal carotid kinking (>60 degrees of angulation) (P <.05), distal stenosis (>20 mm from bifurcation) (P <.01), or wide acoustic shadowing (>1 cm) (P <.01) and in those without these conditions (P <.05). Compared with arteriography, diagnostic accuracy with the new method proved higher for carotid stenoses 50% or greater, 60% or greater, 70% or greater, and 80% or greater; no statistically significant difference was found for carotid stenosis 96% or greater or for carotid occlusion. Compared with data from neurologic assessment and arteriography, method B proved more accurate than method A in designating patients for carotid endarterectomy (P =.014). CONCLUSIONS: The new method significantly improved diagnostic reliability of duplex ultrasound scanning, especially in carotid arteries with kinking, distal stenosis, or wide acoustic shadowing (32.2% of all arteries studied). In clinical practice, we suggest additional use of a lower frequency transducer in cases in which these three conditions are found or suspected at first scanning.

Adult↗

Asymmetric medial degeneration of the ascending aorta in aortic valve disease: a pilot study of surgical management.

BACKGROUND AND AIM OF THE STUDY: In structural aortic valve disease, medial degeneration is often associated with ascending aorta dilatation. This pathology is often asymmetric, with more severe involvement of the convex aspect of the ascending aorta. The condition can be managed with surgical excision of the diseased portion of the aortic wall and remodeling reconstruction at the time of aortic valve replacement (AVR). METHODS: Sixty-one patients underwent AVR and 'waistcoat aortoplasty'. Sinus dilatation was repaired by plicating the subcoronary redundant aortic wall using anchoring sutures of the valve prosthesis. The diseased aortic wall was removed via a triangular resection, and the aorta reconstructed with a double-layer technique, to achieve autologous reinforcement of the convex right posterolateral wall and stress reduction on the aortotomy suture line. Echocardiography was performed preoperatively, immediately postoperatively, and every six months thereafter. The significance of diameter variations was evaluated. RESULTS: There was no hospital mortality, and only low postoperative morbidity. Post-reduction diameters at the sinuses, sinotubular junction and ascending aorta were significantly less than preoperative values (p < 0.0001). During a mean follow up of 33.8 +/- 10.2 months (range: 13-50 months), no significant increase in root (p = 0.32), sinotubular (p = 0.15), or ascending diameter (p = 0.11) was observed. CONCLUSION: The 'waistcoat aortoplasty' should be considered when dealing with asymmetric ascending dilation secondary to aortic valve disease-related medial degeneration. However, additional studies with a longer follow up are needed to confirm these findings.

Adult↗

Aortic valve dysfunction and dilated ascending aorta. A complex and controversial association.

Several pathogenetic mechanisms account for the association of the ascending aorta dilation with aortic valve dysfunction. Functional aortic insufficiency can derive from medial degeneration of the aortic wall and annuloaortic ectasia; leaflet structural disease can determine root dilation by increasing aortic wall stress in case of both regurgitation and stenosis; aortic valve disease and aortic aneurysm can however coexist due to two different intrinsic etiologies. In the attempt to best tailor the surgical correction of such conditions to the underlying causative mechanism, several technical options have already been developed including composite or separate aortic valve and root replacement, valve-sparing operations, and aortoplasty techniques. The criteria for surgical indication cannot leave the underlying pathogenesis out of consideration as well. The newly acquired knowledge in the basic research on this topic is expected to affect the approach to the individual patient in the future.

Aorta↗

Extensive retroperitoneal fibrosis with duodenal and ureteral obstruction associated with giant inflammatory aneurysm of the abdominal aorta.

We report a case of abdominal aortic aneurysm complicated by retroperitoneal fibrosis with both duodenal and bilateral ureteral obstruction. The patient underwent successful bilateral transurethral ureteral stenting, and then he was referred for surgical treatment of the aneurysm. Massive retroperitoneal fibrosis was found at surgery, and the mass was removed along with the diseased aorta, which was replaced by a bifurcated Dacron prosthesis; duodenolysis and ureterolysis were concomitantly performed. Ureteral stents were removed on the 8th postoperative day. Follow-up assessment at 1 year showed normalization of the urinary tract structure at echography and good hemodynamic performance of the vascular prosthesis at Doppler examination. To our knowledge, no other case of duodenal and bilateral ureteral stenosis secondary to massive retroperitoneal reactive fibrosis in association with abdominal aortic aneurysm has been reported.

Aged↗

Surgical experience with "waistcoat aortoplasty": an update.

BACKGROUND: Some patients with primary aortic valve disease can present with an associated asymmetrical dilation of the aortic root and/or ascending aorta without diffuse congenital aortic wall defects. In such cases "waistcoat aortoplasty" has been performed: the present study updates the report of the results of 73 procedures. METHODS: Seventy-three patients underwent aortic valve replacement and waistcoat aortoplasty. Sinus dilation was repaired by plicating the subcoronary redundant aortic wall using the anchoring sutures of the valve prosthesis. Through a triangular resection the most diseased segment of the aortic wall was removed and the aorta was reconstructed with a double layer technique. Thus autologous reinforcement of the convex right postero-lateral wall and stress reduction on the aortotomy suture line were both achieved. Echocardiography was performed preoperatively, postoperatively and then every 6 months. The paired Student's t-test was employed to evaluate the significance of the diameter variations. RESULTS: The procedure was performed with no hospital mortality and a low postoperative morbidity. The post-reduction diameters at the sinuses, sinotubular junction and ascending aorta were significantly smaller than the preoperative ones (p < 0.001). During an echocardiographic follow-up of 39.2 +/- 12.5 months (range 14-58 months), no significant increase in the root (p = 0.18), sinotubular junction (p = 0.22), and ascending diameter (p = 0.34) was observed. CONCLUSIONS: Although further studies are needed to confirm these results in the longer term, waistcoat aortoplasty should be taken into consideration in case of asymmetric ascending dilation secondary to aortic valve disease-related medial degeneration.

Adult↗

Risk of warfarin during pregnancy with mechanical valve prostheses.

OBJECTIVE: To assess the determinants of pregnancy outcome in patients with mechanical valve prostheses anticoagulated with warfarin. METHODS: Between January 1987 and January 2000, 52 patients with mechanical valve prostheses who had 71 pregnancies were anticoagulated with warfarin for the entire duration of pregnancy. Warfarin was withdrawn 48 hours before and 24 hours after a scheduled cesarean delivery carried out by the end of the 37th gestational week. The targeted international normalized ratio ranged between 2.25 and 4.0, depending on the prosthetic model. Exact univariate and multivariable analyses were performed to assess which among the following variables predicted poor pregnancy outcome: patient age, prosthetic model, site of implantation, average international normalized ratio, and average daily dose of warfarin. RESULTS: Pregnancy loss occurred in 23 of 71 of pregnancies, stillbirth in five of 71, embryopathy in four of 71 (two aborted fetuses and two full-term infants). There were no maternal deaths or thromboembolic or hemorrhagic complications. Warfarin daily dosage over 5 mg per day was a significant predictor of poor pregnancy outcome (P <.001). CONCLUSION: The risk for pregnancy complications in patients treated with sodium warfarin is higher when the mean daily dose exceeds 5 mg.

Abortion, Spontaneous↗

Is aortic valve replacement with bileaflet prostheses still contraindicated in the elderly?

BACKGROUND: Prolonged survival in the Western world has increased the number of elderly patients referred for open-heart surgery during the last decade. Aortic valve disease is the most common heart valve disease in aged patients. Which aortic valve substitute is best employed in the elderly is still a debated matter. The main concern is about the thromboembolic and hemorrhagic risks related to mechanical valves and anticoagulation. OBJECTIVE: The study aimed at reviewing clinical results after isolated aortic valve replacement with bileaflet prostheses in patients over 70 years and at retrospectively comparing them with those of a group of otherwise comparable patients under 50 years of age who underwent isolated aortic valve replacement with a mechanical device. METHODS: The study population included 118 consecutive elderly patients (group A) operated on between January 1988 and January 1999 and 122 young patients (group B) who underwent aortic valve replacement during the same time period. Patients with associated coronary artery disease, mitral stenosis or regurgitation, type A aortic dissection, and infective endocarditis were excluded from the study. Preoperative clinical data, early and late postoperative mortality, all valve-related complications, and all data concerning the anticoagulation status - including the mean international normalized ratio (INR) and the mean time interval between each INR assay - were compared between the two groups. RESULTS: The hospital mortality was significantly lower in group B (2.45%) than in group A (9.3%; p = 0.022). The mean follow-up period was 50.98 +/- 2.23 months. The 12-year actuarial survival was significantly lower (69.6 +/- 0.08%) in group A than in group B (94.4 +/- 0.02%; p < 0.001). No significant difference was found in terms of valve-related and anticoagulation-related complication rates and actuarial freedom as well as mean interval between consecutive INR checks (p = 0.219) and mean INR value (p = 0.914). CONCLUSIONS: Bileaflet prostheses in elderly patients can achieve excellent early and late clinical results, with a low incidence of anticoagulation-related complications and an extremely low risk of a reoperation. Older age can no longer be considered a contraindication to bileaflet prosthesis implantation in the aortic position.

Adult↗